DANPEX CORPORATION
EN-9000
NIC Type | Ethernet |
Transfer Rate | 10Mbps |
Data Bus | 32-bit EISA |
Topology | Star Linear Bus |
Wiring Type | RG58A/U 50ohm coaxial Shielded/Unshielded twisted pair AUI transceiver via DB-15 port |
Boot ROM | Available |
ACTIVITY LED ENABLE | ||
Setting | JP1 | |
» | Disabled | Pins 1 & 2 closed |
Enabled | Pins 2 & 3 closed | |
Note:If the network hub has an activity LED for each line, setting this option to enabled will allow the hub LED to operate properly |
CABLE TYPE | ||
Type | JP6 | |
» | Software select | Pins 1 & 2 closed |
RG58A/U 50ohm coaxial | Pins 2 & 3 closed |
ONBOARD TERMINATOR | ||
Setting | JP7 | |
» | Disabled | Pins 2 & 3 closed |
Enabled | Pins 1 & 2 closed | |
Note:When using RG58A/U 50ohm coaxial cable the onboard 50ohm terminator may be used instead of using a T-connector and an external terminator. |
DIAGNOSTIC LED(S) | ||
LED | Status | Condition |
LED1 | On | Data is being transmitted |
LED1 | Off | Data is not being transmitted |
LED2 | On | Twisted pair connection is good |
LED2 | Off | Twisted pair connection is broken |
LED3 | On | Data is being received |
LED3 | Off | Data is not being received |
LED4 | On | Collision detected on network |
LED4 | Off | No collisions detected on network |
FACTORY CONFIGURED SETTINGS | |
Jumper | Setting |
JP2 | Unused |
JP3 | Unused |
JP4 | Unused |
JP5 | Unused |