TRENDWARE INTERNATIONAL, INC.
TE-32V
NIC Type: | Ethernet |
Transfer Rate: | 10Mbps |
Data Bus: | 32-bit VESA-local bus |
Topology: | Linear bus Star |
Wiring Type | AUI transceiver via DB-15 port RG-58A/U 50ohm coaxial Shielded/Unshielded twisted pair |
Boot ROM | Available |
WIRING TYPE | |||
Setting | JP1/jumper A | JP1/jumper B | |
» | Unshielded twisted pair | Closed | Open |
| AUI transceiver via DB-15 port | Open | Closed |
| RG-58A/U 50ohm coaxial | Closed | Closed |
BOOT ROM | ||
Setting | JP2/jumper A | |
» | Disabled | Open |
| Enabled | Closed |
BOOT ROM ADDRESS | |||
Address | JP2/jumper B | JP2/jumper C | |
» | D0000h | Closed | Open |
| C0000h | Open | Open |
| C8000h | Open | Closed |
| D8000h | Closed | Closed |
INTERRUPT SELECT - JP3 | |||||||||||
IRQ | A | B | C | D | E | F | G | H | I | J | |
» | IRQ5 | Open | Open | Closed | Open | Open | Open | Open | Open | Open | Open |
| IRQ3 | Closed | Open | Open | Open | Open | Open | Open | Open | Open | Open |
| IRQ4 | Open | Closed | Open | Open | Open | Open | Open | Open | Open | Open |
| IRQ6 | Open | Open | Open | Closed | Open | Open | Open | Open | Open | Open |
| IRQ7 | Open | Open | Open | Open | Closed | Open | Open | Open | Open | Open |
| IRQ9 | Open | Open | Open | Open | Open | Closed | Open | Open | Open | Open |
| IRQ11 | Open | Open | Open | Open | Open | Open | Closed | Open | Open | Open |
| IRQ12 | Open | Open | Open | Open | Open | Open | Open | Closed | Open | Open |
| IRQ14 | Open | Open | Open | Open | Open | Open | Open | Open | Closed | Open |
| IRQ15 | Open | Open | Open | Open | Open | Open | Open | Open | Open | Closed |
I/O ADDRESS | |||
Address | JP4/jumper A | JP4/jumper B | |
» | 300h | Closed | Closed |
| 320h | Closed | Open |
| 340h | Open | Closed |
| 360h | Open | Open |
VL-BUS SPEED | ||
Setting | JP5 | |
» | Speed < 33 MHz | Open |
| Speed > 33MHz | Closed |
DIAGNOSTIC LEDS | ||
LED | Status | Condition |
LED1 | On | Power on |
LED1 | Blinking | Data is being transmitted |
LED2 | On | Network connected successfully (UTP connection only) |
LED2 | Blinking | Data is being received |
LED3 | On | Network is not connected (RG-58A/U 50ohm coaxial connection only) |
LED3 | Blinking | Collision detected |
LED4 | Blinking | Transmission interrupted due to packet longer than allowable length (jabber) |