MAXTECH CORPORATION
EN-4300
NIC Type | Ethernet |
Network Transfer Rate | 10Mbps |
Data Bus | 32-bit VESA Local Bus |
Topology | Linear Bus, Star |
Wiring Type | Unshielded twisted pair (location unidentified) RG-58A/U 50ohm coaxial (location unidentified) |
Boot ROM | Available (location unidentified) |
Diagram not available
USER CONFIGURABLE SETTINGS | |||
Function | Label | Position | |
| » | Jumperless mode | JP3 | Pins 1 & 2 closed |
Jumpered mode | JP3 | Pins 2 & 3 closed | |
BASE I/O ADDRESS SELECTION | |||
Address | J0 | J1 | J2 |
Software | Closed | Open | Open |
240h | Open | Closed | Open |
280h | Closed | Closed | Open |
2C0h | Open | Open | Closed |
300h | Open | Open | Open |
320h | Closed | Open | Closed |
340h | Open | Closed | Closed |
360h | Closed | Closed | Closed |
INTERRUPT SELECTION | |||
IRQ | J3 | J4 | J5 |
2 | Closed | Closed | Open |
3 | Open | Open | Open |
4 | Closed | Open | Open |
5 | Open | Closed | Open |
10 | Open | Open | Closed |
11 | Closed | Open | Closed |
12 | Open | Closed | Closed |
15 | Closed | Closed | Closed |
ROM ADDRESS SELECTION | ||||
Address | J6 | J7 | J8 | J9 |
Disabled | Open | Open | Open | Open |
C000h | Closed | Open | Open | Open |
C400h | Closed | Closed | Open | Open |
C800h | Open | Open | Closed | Open |
CC00h | Closed | Open | Closed | Open |
D000h | Open | Closed | Closed | Open |
D400h | Closed | Closed | Closed | Open |
D800h | Open | Open | Open | Closed |
DC00h | Closed | Open | Open | Closed |