INVISIBLE SOFTWARE, INC.
ETHERNET 2000A/V3.X
Card Type | Network Interface Card |
NIC Type | Ethernet |
Maximum Onboard Memory | Unidentified |
Boot ROM | Available |
Network Transfer Rate | 10Mbps |
Topology | Linear Bus, Star |
Wiring Type | Unshielded twisted pair (RJ-45), AUI transceiver via DB-15 port, RG-58A/U 50ohm coaxial |
Data Bus | 16-bit ISA |
CONNECTIONS | |||
Function | Label | Function | Label |
UTP connector (RJ-45) | J7 | BNC connector | J15 |
AUI connector | J9 | External LED connector | LED1 |
USER CONFIGURABLE SETTINGS | |||
Function | Label | Position | |
| Boot ROM Enabled | J2/D | Closed |
» | Boot ROM Disabled | J2/D | Open |
| SQE enabled | J3 | Pins 1 & 2 closed |
| SQE disabled | J3 | Pins 2 & 3 closed |
| UTP cable long | J4 | Pins 2 & 3 closed |
| UTP cable normal | J4 | Pins 1 & 2 closed |
| Link enabled | J5 | Pins 2 & 3 closed |
| Link disabled | J5 | Pins 1 & 2 closed |
» | Main Board compatibility | J8 | Open |
| Main Board compatibility option enabled | J8 | Closed |
| NE2000 compatibility | J11 | Open |
| NE1000 compatibility | J11 | Closed |
BASE I/O ADDRESS SELECTION | |||||
Setting | J10/A | J10/B | J10/C | J10/D | |
| 200h | Open | Closed | Closed | Closed |
| 220h | Open | Closed | Closed | Open |
| 240h | Open | Closed | Open | Closed |
| 260h | Open | Closed | Open | Open |
| 280h | Open | Open | Closed | Closed |
| 2A0h | Open | Open | Closed | Open |
| 2C0h | Open | Open | Open | Closed |
» | 300h | Closed | Closed | Closed | Closed |
| 320h | Closed | Closed | Closed | Open |
| 340h | Closed | Closed | Open | Closed |
| 360h | Closed | Closed | Open | Open |
| 380h | Closed | Open | Closed | Closed |
INTERRUPT SELECTION | ||||||
IRQ | J14/A | J14/B | J14/C | J14/D | J14/E | |
| 2/9 | Closed | Open | Open | Open | Open |
» | 3 | Open | Closed | Open | Open | Open |
| 4 | Open | Open | Closed | Open | Open |
| 5 | Open | Open | Open | Closed | Open |
| 7 | Open | Open | Open | Open | Closed |
| 10 | Open | Open | Open | Open | Open |
| 11 | Open | Open | Open | Open | Open |
| 12 | Open | Open | Open | Open | Open |
| 14 | Open | Open | Open | Open | Open |
| 15 | Open | Open | Open | Open | Open |
INTERRUPT SELECTION CONTINUED | ||||||
IRQ | J14/F | J14/G | J14/H | J14/I | J14/J | |
| 2/9 | Open | Open | Open | Open | Open |
» | 3 | Open | Open | Open | Open | Open |
| 4 | Open | Open | Open | Open | Open |
| 5 | Open | Open | Open | Open | Open |
| 7 | Open | Open | Open | Open | Open |
| 10 | Closed | Open | Open | Open | Open |
| 11 | Open | Closed | Open | Open | Open |
| 12 | Open | Open | Closed | Open | Open |
| 14 | Open | Open | Open | Closed | Open |
| 15 | Open | Open | Open | Open | Closed |
CABLE TYPE SELECTION | |||
Type | J6/A-D | J12 | J13 |
AUI transceiver via DB-15 port | Open | Open | Closed |
RG-58A/U 50ohm coaxial | Open | Closed | Open |
Unshielded twisted pair | Closed | Open | Open |
ROM ADDRESS SELECTION | ||||
Address | J2/A | J2/B | J2/C | |
| C000h | Open | Open | Open |
| C400h | Open | Open | Closed |
» | C800h | Open | Closed | Open |
| CC00h | Open | Closed | Closed |
| D000h | Closed | Open | Open |
| D400h | Closed | Open | Closed |
| D800h | Closed | Closed | Open |
| DC00h | Closed | Closed | Closed |
DIAGNOSTIC LED(S) | |||
LED | Color | Status | Condition |
D1 | Yellow | On | Polarity reversed (UTP) |
D1 | Green | On/Blinking | Polarity normal (UTP) (SQE enabled) |
D1 | Green | On/Blinking | Data is being received (SQE disabled) |
D1 | Green | Off | Data is not being received (SQE disabled) |