FOX RESEARCH, INC.
10-NET CIRCUIT BOARD (ASSY. #155-000120 AND #155-000160)
NIC Type | Proprietary |
Chip Set | SEEQ DC 8001 |
Data Bus | 8-bit ISA |
Network Transfer Rate | 1Mbps |
Topology | Linear Bus |
Wiring Type | Unshielded twisted pair |
Boot ROM | Available |

CONNECTIONS | |
Function | Label |
Unshielded twisted pair via 3-pin connector | J1 |
USER CONFIGURABLE SETTINGS | |||
Setting | Label | Position | |
| » | Base I/O address set to 300h | W1 | Pins 1 & 2 closed |
Base I/O address set to 310h | W1 | Pins 2 & 3 closed | |
DMA CHANNEL | |||
Setting | W2 | W4 | |
| » | DMA1 | Pins 1 & 2 closed | Pins 1 & 2 closed |
DMA3 | Pins 2 & 3 closed | Pins 2 & 3 closed | |
INTERRUPT | ||||||
Setting | W3/A | W3/B | W3/C | W3/D | W3/E | |
| » | IRQ2 | Closed | Open | Open | Open | Open |
IRQ3 | Open | Closed | Open | Open | Open | |
IRQ4 | Open | Open | Closed | Open | Open | |
IRQ5 | Open | Open | Open | Closed | Open | |
IRQ7 | Open | Open | Open | Open | Closed | |
BOOT ROM ADDRESS | ||
Setting | W5 | |
| » | Disabled | Pins 2 & 4 closed |
EC000h | Pins 1 & 2 closed | |
EE000h | Pins 2 & 3 closed | |
DIAGNOSTIC LED(S) | |||
LED | Color | Status | Condition |
LED1 | Unidentified | On | Card has failed |
LED1 | Unidentified | Off | Card is operating normally |