COMPU-SHACK PRODUCTION, GMBH
CS-ARCNET-KARTE TURBO, CS-ARCNET-KARTE SPECIAL
NIC Type: | ARCnet |
Transfer Rate: | 2.5Mbps |
Data Bus: | 8-bit ISA |
Topology: | Linear Bus |
Wiring Type | RG62A/U 93ohm coaxial |
Boot ROM | Available |

INTERRUPT SELECT - J2 | ||||||
IRQ | Jumper A | Jumper B | Jumper D | Jumper D | Jumper E | |
| » | IRQ2 | Closed | Open | Open | Open | Open |
IRQ3 | Open | Closed | Open | Open | Open | |
IRQ4 | Open | Open | Closed | Open | Open | |
IRQ5 | Open | Open | Open | Closed | Open | |
IRQ7 | Open | Open | Open | Open | Closed | |
RESPONSE TIME-OUTS | |||
Response Time | J4/jumper A | J4/jumper B | |
| » | 74.7µs | Open | Open |
283.4µs | Closed | Open | |
561.8µs | Open | Closed | |
1118.6µs | Closed | Closed | |
BOOT ROM | ||
Setting | S1/1 | |
| » | Disabled | Off |
Enabled | On | |
I/O ADDRESS | |||||||
Address | S1/1 | S1/2 | S1/3 | S1/4 | S1/5 | S1/6 | |
| » | 2E0h | Off | On | Off | Off | Off | On |
200h | Off | On | On | On | On | On | |
210h | Off | On | On | On | On | Off | |
220h | Off | On | On | On | Off | On | |
230h | Off | On | On | On | Off | Off | |
240h | Off | On | On | Off | On | On | |
250h | Off | On | On | Off | On | Off | |
260h | Off | On | On | Off | Off | On | |
270h | Off | On | On | Off | Off | Off | |
280h | Off | On | Off | On | On | On | |
290h | Off | On | Off | On | On | Off | |
2A0h | Off | On | Off | On | Off | On | |
2B0h | Off | On | Off | On | Off | Off | |
2C0h | Off | On | Off | Off | On | On | |
2D0h | Off | On | Off | Off | On | Off | |
2F0h | Off | On | Off | Off | Off | Off | |
300h | Off | Off | On | On | On | On | |
310h | Off | Off | On | On | On | Off | |
320h | Off | Off | On | On | Off | On | |
330h | Off | Off | On | On | Off | Off | |
340h | Off | Off | On | Off | On | On | |
350h | Off | Off | On | Off | On | Off | |
360h | Off | Off | On | Off | Off | On | |
370h | Off | Off | On | Off | Off | Off | |
380h | Off | Off | Off | On | On | On | |
390h | Off | Off | Off | On | On | Off | |
3A0h | Off | Off | Off | On | Off | On | |
3B0h | Off | Off | Off | On | Off | Off | |
3C0h | Off | Off | Off | Off | On | On | |
3D0h | Off | Off | Off | Off | On | Off | |
3E0h | Off | Off | Off | Off | Off | On | |
3F0h | Off | Off | Off | Off | Off | Off | |
MEMORY ADDRESS | |||||
Address | S1/7 | S1/8 | S1/9 | S1/10 | |
| » | D0000h | On | Off | On | On |
C0000h | On | On | On | On | |
C4000h | On | On | On | Off | |
C8000h | On | On | Off | On | |
CC000h | On | On | Off | Off | |
D4000h | On | Off | On | Off | |
D8000h | On | Off | Off | On | |
DC000h | On | Off | Off | Off | |
E0000h | Off | On | On | On | |
E4000h | Off | On | On | Off | |
E8000h | Off | On | Off | On | |
EC000h | Off | On | Off | Off | |
F0000h | Off | Off | On | On | |
F4000h | Off | Off | On | Off | |
F8000h | Off | Off | Off | On | |
FC000h | Off | Off | Off | Off | |
NODE ID NUMBER | ||||||||
ID # | S2/1 | S2/2 | S2/3 | S2/4 | S2/5 | S2/6 | S2/7 | S2/8 |
1 | On | Off | Off | Off | Off | Off | Off | Off |
255 | On | On | On | On | On | On | On | On |
Note:Nodes can be numbered from 1 to 255. The switches are a binary representation of the node numbers. When a switch is on, the corresponding bit is set to 1 and has the following decimal value: S2/1=1, S2/2=2, S2/3=4, S2/4=8, S2/5=16, S2/6=32, S2/7=64, S2/8=128. | ||||||||
DIAGNOSTIC LED | |
Status | Condition |
On | Data is being transmitted or received |
Off | Data is not being transmitted or received |