MOTOROLA, INC.
FT100 M
Card Type | T1 CSU/DSU, Ethernet |
Chip Set | Unidentified |
I/O Options | Monitor ports, alarm port |
Network Transfer Rate | 10Mbps |
Topology | Star |
Wiring Type | Unshielded twisted pair |
Transfer Rate | 1.544Mbps |
Data Bus | Serial |
Protocol | AMI, B8ZS |
Frame Type | SF, ESF |

CONNECTIONS | |||
Function | Label | Function | Label |
Monitor receive | CN1 | Serial control port | CN6 |
Monitor transmit | CN2 | DSX-1, RS-232, RS-449, RS-530, or V.35 serial data port 2 (on daughterboard) | CN7 |
T1 interface | CN3 | DC power in | CN8 |
UTP connector | CN4 | Alarm port (see pinout below) | SC1 |
DSX-1, RS-232, RS-449, RS-530, or V.35 serial data port 1 (on daughterboard) | CN5 | ||
Note:Standard serial ports are provided on included adapter cables. | |||
SC1 PINOUT | |||
Function | Pin | Function | Pin |
Normally closed connection | 1 | Signal common | 3 |
Normally open connection | 2 | Not used | 4 |
USER CONFIGURABLE SETTINGS | |||
Setting | Label | Position | |
| » | Signal ground connected to chassis ground | E1 | Pins 2 & 3 closed |
Signal ground not connected to chassis ground | E1 | Pins 1 & 2 closed | |
| » | Factory configured - do not alter | S1/1 | Unidentified |
| » | Factory configured - do not alter | S1/2 | Unidentified |
| » | Factory configured - do not alter | S1/3 | Unidentified |
| » | Factory configured - do not alter | S1/4 | Unidentified |
| » | Factory configured - do not alter | S1/5 | Unidentified |
| » | Factory configured - do not alter | S1/6 | Unidentified |
| » | Factory configured - do not alter | S1/7 | Unidentified |
| » | Factory configured - do not alter | S1/8 | Unidentified |
| » | Factory configured - do not alter | S2/1 | Unidentified |
| » | Factory configured - do not alter | S2/2 | Unidentified |
| » | Factory configured - do not alter | S2/3 | Unidentified |
| » | Factory configured - do not alter | S2/4 | Unidentified |
| » | Factory configured - do not alter | S2/5 | Unidentified |
| » | Factory configured - do not alter | S2/6 | Unidentified |
| » | Factory configured - do not alter | S2/7 | Unidentified |
| » | Factory configured - do not alter | S2/8 | Unidentified |
| » | Factory configured - do not alter | S28/1 | On |
| » | Factory configured - do not alter | S28/2 | On |
| » | Factory configured - do not alter | S28/3 | On |
| » | Factory configured - do not alter | S28/4 | On |
| » | Factory configured - do not alter | S28/5 | On |
| » | Factory configured - do not alter | S28/6 | On |
| » | Factory configured - do not alter | S28/7 | On |
| » | Factory configured - do not alter | S28/8 | Off |
USER CONFIGURABLE SETTINGS (CON’T) | |||
Setting | Label | Position | |
| » | One stop bit selected | S29/5 | On |
Two stop bits selected | S29/5 | Off | |
| » | 8 data bits selected | S29/6 | On |
7 data bits selected | S29/6 | Off | |
CONTROL PORT CONFIGURATION | ||||
Setting | E25 | E26 | E27 | |
| » | DCE | Pins 1 & 2, 3 & 4 closed | Pins 1 & 2, 3 & 4 closed | Pins 1 & 2, 3 & 4 closed |
DTE | Pins 1 & 3, 2 & 4 closed | Pins 1 & 3, 2 & 4 closed | Pins 1 & 3, 2 & 4 closed | |
SERIAL PORT SPEED SELECTION | |||
Setting | S29/1 | S29/2 | |
2400bps | Off | Off | |
4800bps | Off | On | |
9600bps | On | Off | |
| » | 19.2Kbps | On | On |
DATA PARITY SELECTION | |||
Setting | S29/3 | S29/4 | |
| » | Disabled | On | N/A |
Even | Off | On | |
Odd | Off | Off | |
FLOW CONTROL SELECTION | |||
Setting | S29/7 | S29/8 | |
| » | Flow control disabled | On | On |
XON/XOFF flow control enabled | On | Off | |
RTS/CTS flow control enabled | Off | On | |
DIAGNOSTIC LED(S) | |||
LED | Color | Status | Condition |
TXD2 | Green | On | Data is being transmitted to port 2 |
TXD2 | Green | Off | Data is not being transmitted to port 2 |
RXD2 | Green | On | Data is being received from port 2 |
RXD2 | Green | Off | Data is not being received from port 2 |
TXD1 | Green | On | Data is being transmitted to port 1 |
TXD1 | Green | Off | Data is not being transmitted to port 1 |
RXD1 | Green | On | Data is being received from port 1 |
RXD1 | Green | Off | Data is not being received from port 1 |
YEL | Red | On | Yellow alarm condition detected |
YEL | Red | Off | Yellow alarm condition not detected |
AIS | Red | On | All Ones Signal detected |
AIS | Red | Off | All Ones Signal not detected |
DIAGNOSTIC LED(S) (CON’T) | |||
LED | Color | Status | Condition |
LOS | Red | On | Loss of signal detected |
LOS | Red | Off | Loss of signal not detected |
SYN | Green | On | Valid framing pattern received from T1 interface |
SYN | Green | Off | Valid framing pattern not received from T1 interface |
PWR | Green | On | Power is on |
PWR | Green | Off | Power is off |
USER CONFIGURABLE SETTINGS | |||
Setting | Label | Position | |
| » | Factory configured - do not alter | SW1 | Off |
| » | Factory configured - do not alter | SW2 | Off |
| » | Factory configured - do not alter | SW3 | On |
| » | Factory configured - do not alter | SW4 | On |
| » | Factory configured - do not alter | SW5 | Off |
| » | Factory configured - do not alter | SW6 | On |
| » | Factory configured - do not alter | SW7 | Off |
| » | Factory configured - do not alter | SW8 | Off |
MISCELLANEOUS TECHNICAL NOTES |
Diagram not available. |
FT100 M (RS-449/530 INTERFACE)
MISCELLANEOUS TECHNICAL NOTES |
Diagram not available. The card's jumper(s) must be set for Test Mode operation. |