MOTOROLA, INC.
UTA220, UTA220K
Card Type | ISDN TA |
Chip Set | Unidentified |
I/O Options | 25-pin serial ports (4), ISDN U interface via RJ-48 connector, power |
ISDN Data Rate | 128Kbps |
ISDN Modulation Protocol | V.120, HDLC |
Error Correction/Compression | Unidentified |
Data Bus | External |

CONNECTIONS | ||||||
Function | Label | Function | Label | |||
25-pin serial port 1 | CN1 | ISDN U interface (RJ-48) | CN5 | |||
25-pin serial port 2 | CN2 | Power | CN6 | |||
25-pin serial port 3 | CN3 | Power switch | SW1 | |||
25-pin serial port 4 | CN4 | |||||
Note: Serial ports 3 & 4 are optional, and not featured in standard version. | ||||||
DIAGNOSTIC LED(S) | |||
LED | Color | Status | Condition |
B1 | Unidentified | On | B-channel 1 is active |
B1 | Unidentified | Off | B-channel 1 is inactive |
B2 | Unidentified | On | B-channel 2 is active |
B2 | Unidentified | Off | B-channel 2 is inactive |
D | Unidentified | On | All B-channels are available |
D | Unidentified | Blinking (single) | Connection is established on ISDN U interface |
D | Unidentified | Blinking (double) | Communications are established with the switch |
D | Unidentified | Off | Connection is not established on ISDN U interface |
DP | Unidentified | On | D-channel is available for packet calls |
DP | Unidentified | Off | D-channel is not available for packet calls |
T | Unidentified | On | Unit is conducting a test |
T | Unidentified | Off | Unit is not conducting a test |
PW | Unidentified | On | Power is on |
PW | Unidentified | Off | Power is off |
SUPPORTED COMMAND SET |
Basic AT Commands |
AT, ‘+++’, A/ |
A, E, O, V, Z |
&R, &V, &Y, &Z |
S Registers |
S0, S1, S2, S3, S4, S5, S7, S10, S12, S25, S26 |
Note: See MHI Help File for full command documentation. |
Proprietary AT Command Set
COMMUNICATIONS MODE | |
Type: | Configuration |
Format: | AT [cmds] &Qn [cmds] |
Description: | Selects communications mode options |
Command | Mode |
&Q0 | Asynchronous mode, serial port speed follows connect speed. |
&Q1 | Synchronous connect mode; DTR disc delay. |
&Q2 | Synchronous connect mode; DTR dialing |
DATA CARRIER DETECT (DCD) | ||
Type: | Configuration | |
Format: | AT [cmds] &Cn [cmds] | |
Description: | Controls the behaviour of the CD signal. | |
Command | Function | |
í &C0 | DCD forced high. | |
&C1 | DCD normal. | |
&C2 | DCD forced low on disconnect. | |
DATA SET READY (DSR) | |
Type: | Configuration |
Format: | AT [cmds] &Sn [cmds] |
Description: | Selects DSR options |
Command | Function |
&S0 | DSR forced high |
&S1 | DSR high only while modem is handshaking or connected, except in test modes |
DIAL | |
Type: | Immediate |
Format: | AT [cmds] D<#> [cmds] |
Description: | Dials telephone number according to any modifiers included in the string |
Note: | Any combination of modifiers can be used to produce the desired dial functions in sequence. |
Command | Function |
DS=n | Dial stored telephone number n |
D; | Modem returned to on-line command mode after dialing. The semicolon can only be placed at the end of the dial command. |
DTR AUTODIAL | ||
Type: | Configuration | |
Format: | AT [cmds] &Ln [cmds] | |
Description: | Causes the TA to repeatedly dial the first stored number on high DTR until it connects. | |
Command | Function | |
í &L0 | DTR autodialing disabled. | |
&L1 | DTR autodialing enabled. | |
DTR SIGNAL | ||
Type: | Configuration | |
Format: | AT [cmds] &Dn [cmds] | |
Description: | Controls the behaviour of the DTR signal. | |
Command | Function | |
&D0 | DTR forced high. | |
&D1 | TA enters command mode when DTR goes low. | |
&D2 | TA hangs up and returns to command mode on low DTR. | |
&D3 | TA resets on low DTR. | |
&D9 | TA dials first stored number on high DTR, hangs up and returns to command mode on low DTR. | |
EXTENDED RESULT CODES | |
Type: | Configuration |
Format: | AT [cmds] Wn [cmds] |
Description: | Enables/disables CARRIER/PROTOCOL result codes |
Command | Function |
í W0 | CARRIER and PROTOCOL extended result codes are disabled. |
W1 | CARRIER and PROTOCOL extended result codes are enabled. |
FACTORY DEFAULT PROFILE | |
Type: | Configuration |
Format: | AT [cmds] &Fn [cmds] |
Description: | Sets values in active profile to values found in the default profile |
Command | Function |
&F0 | Load factory profile 0 |
&F1 | Load factory profile 1 |
&F9 | Reloads global profile |
FLOW CONTROL | |
Type: | Configuration |
Format: | AT [cmds] &Kn [cmds] |
Description: | Enables flow control options |
Command | Function |
&K0 | Flow control disabled |
&K3 | RTS/CTS flow control enabled |
&K4 | XON/XOFF flow control enabled |
&K5 | Transparent XON/XOFF flow control enabled |
HOOK CONTROL | |
Type: | Immediate |
Format: | AT [cmds] H [cmds] |
Description: | Commands modem to go on-hook (hang up) |
REPORT INFORMATION | |
Type: | Immediate |
Format: | AT [cmds] In [cmds] |
Description: | Displays information requested |
Command | Function |
I0 | Reports product ID |
I1 | Reports ROM checksum |
I2 | Tests and reports ROM checksum |
I3 | Reports revision information |
RESTART NET | |
Type: | Configuration |
Format: | AT [cmds] Z9 [cmds] |
Description: | Restarts net |
RESULT CODES | |
Type: | Configuration |
Format: | AT [cmds] Qn [cmds] |
Description: | Enables modem to send result codes to the DTE |
Command | Function |
Q0 | Result code sending enabled |
Q1 | Result code sending disabled |
Q2 | Result code sending disabled during answer mode |
SELECT CALL PROGRESS RESULT CODES | |
Type: | Configuration |
Format: | AT [cmds] Xn [cmds] |
Description: | Enables selection of tone detection and associated result code format options |
Command | Function |
X0 | Busy and dial tone detection disabled; result codes 0 - 4 enabled. |
X1 | Result codes 0 - 5 ,10 - 15, 17 - 19, 28, & 32 enabled. |
X2 | Result codes 0 - 5 ,10 - 15, 17 - 19, 28, & 32 enabled. |
X3 | Result codes 0 - 5 , 7, 10 - 15, 17 - 19, 28, & 32 enabled. |
X4 | Result codes 0 - 5 , 7, 10 - 15, 17 - 19, 28, & 32 enabled. |
STORE ACTIVE PROFILE | |
Type: | Configuration |
Format: | AT [cmds] &Wn [cmds] |
Description: | Writes the values for the active profile into the non-volatile RAM |
Command | Function |
&W0 | Write the active profile to stored profile 0 |
&W1 | Write the active profile to stored profile 1 |
&W9 | Stores global profile |
TEST MODES | |
Type: | Immediate |
Format: | AT [cmds] &Tn |
Description: | Selects test options |
Command | Function |
&T0 | End current test |
&T1 | Begin local analog loopback test |
&T3 | Begin local digital loopback test |
&T8 | Begin bilateral loopback test |
&T9 | Begin local terminal loopback test |
Extended AT Command Set
ANSWER MODE | ||
Type: | Configuration | |
Format: | AT [cmds] %A99=x [cmds] | |
Description: | Selects the mode the TA will use to answer calls | |
Command | Function | |
í %A99=N | Normal mode enabled | |
%A99=V | Voice mode enabled | |
DIAL MODE | ||
Type: | Configuration | |
Format: | AT [cmds] %A97=x [cmds] | |
Description: | Selects what type of dialing the TA will use. | |
Command | Function | |
í %A97=E | Enbloc dialing enabled. | |
%A97=O | Overlap dialing enabled. | |
ECHO DISABLE | ||
Type: | Configuration | |
Format: | AT [cmds] %A96=n [cmds] | |
Description: | Selects whether the TA will send a tone to disable the echo canceller. | |
Command | Function | |
í %A96=0 | TA will not send echo canceller disable tone. | |
%A96=1 | TA will send echo canceller disable tone. | |
FLOW CONTROL TYPE | |
Type: | Configuration |
Format: | AT [cmds] \Qn [cmds] |
Description: | Sets type of flow control used by modem |
Command | Function |
\Q0 | Flow control disabled |
\Q2 | Unidirectional RTS/CTS flow control enabled |
\Q3 | Bi-directional RTS/CTS flow control enabled |
\Q4 | Bi-directional XON/XOFF flow control enabled |
\Q5 | Transparent XON/XOFF flow control enabled |
\Q6 | Unidirectional XON/XOFF flow control enabled |
ORIGINATE MODE | ||
Type: | Configuration | |
Format: | AT [cmds] %A98=x [cmds] | |
Description: | Selects the mode the TA will use to originate calls | |
Command | Function | |
í %A98=N | Normal mode enabled | |
%A98=V | Voice mode enabled | |
PROTOCOL | ||
Type: | Configuration | |
Format: | AT [cmds] %A2=n [cmds] | |
Description: | Sets the protocol that the TA uses for rate adaptation. | |
Command | Function | |
%A2=0 | TA will use clear channel mode. | |
%A2=1 | TA will use TLink. | |
í %A2=2 | TA will use V.120 protocol. | |
%A2=3 | TA will use Bonding mode | |
RESTART | |
Type: | Immediate |
Format: | AT [cmds] %Z1 [cmds] |
Description: | Restarts UTA |
TRANSMISSION SPEED | ||
Type: | Configuration | |
Format: | AT [cmds] %A4=n [cmds] | |
Description: | Sets the transmission speed of the TA. | |
Command | Function | |
í %A4=0 | Transmission speed is 64Kbps. | |
%A4=1 | Transmission speed is 56Kbps. | |
V.120 FRAME SELECTION | ||
Type: | Configuration | |
Format: | AT [cmds] %E9=n [cmds] | |
Description: | Selects frame usage | |
Command | Function | |
%E9=0 | I Frames enabled | |
í %E9=1 | UI Frames enabled | |
V.120 PROTOCOL | ||
Type: | Configuration | |
Format: | AT [cmds] %E7=n [cmds] | |
Description: | Sets communications mode | |
Command | Function | |
%E7=0 | Transparent to all bits (SYNC/ASYNC) according to &Q | |
í %E7=1 | Protocols enabled (SDLC) | |
V.120 RECEIVE FRAME SIZE | |
Type: | Configuration |
Format: | AT [cmds] %E1=n [cmds] |
Default: | 260 |
Range: | 1 - 260 |
Unit: | 1 byte |
Description: | Sets the maximum size of a received V.120 frame. |
V.120 TRANSMIT FRAME SIZE | |
Type: | Configuration |
Format: | AT [cmds] %E0=n [cmds] |
Default: | 260 |
Range: | 1 - 260 |
Unit: | 1 byte |
Description: | Sets the maximum size of a transmitted V.120 frame. |
V.120 TRANSMIT TIMER | |
Type: | Configuration |
Format: | AT [cmds] %E3=n [cmds] |
Default: | 5 |
Range: | 1 - 255 |
Unit: | Unidentified |
Description: | Sets the V.120 T200 transmission timer. |
V.120 WINDOW SIZE | |
Type: | Configuration |
Format: | AT [cmds] %E2=n [cmds] |
Default: | 8 |
Range: | 1 - 127 |
Unit: | Unidentified |
Description: | Sets the size of the V.120 window. |
X.25 AUTO-ANSWER | ||
Type: | Configuration | |
Format: | AT [cmds] %B97=x [cmds] | |
Description: | Sets whether the TA will auto-answer an incoming X.25 virtual call. | |
Command | Function | |
%B97=D | Auto-answer disabled. | |
í %B97=E | Auto-answer enabled. | |
X.25 CALL CHARGING | ||
Type: | Configuration | |
Format: | AT [cmds] %B10=n [cmds] | |
Description: | Sets the type of call charging for X.25. | |
Command | Function | |
í %B10=0 | X.25 will use normal call charging. | |
%B10=1 | X.25 will use reverse call charging. | |
X.25 CLOSED USER GROUP | ||
Type: | Configuration | |
Format: | AT [cmds] %B8=n [cmds] | |
Description: | Selects the type of Closed User Group used for X.25. | |
Command | Function | |
í %B8=0 | CUG not used. | |
%B8=1 | Basic CUG used. | |
%B8=2 | CUG with outgoing access only used. | |
%B8=3 | CUG will full access used. | |
X.25 CLOSED USER GROUP ID | |
Type: | Configuration |
Format: | AT [cmds] %B9=nnnn [cmds] |
Default: | 0000 |
Unit: | ASCII |
Description: | Sets the ID for the X.25 CUG. |
X.25 CODE - INCOMING | ||
Type: | Read-only | |
Format: | AT [cmds] %B16 [cmds] | |
Description: | Stores the result code for incoming X.25 virtual calls. | |
Value | Meaning | |
0 | Call was not redirected. | |
1 | Station was busy. | |
9 | Station was out of order. | |
15 | Call was redirected. | |
X.25 CODE - OUTGOING | ||
Type: | Read-only | |
Format: | AT [cmds] %B15 [cmds] | |
Description: | Stores the result code for outgoing X.25 virtual calls. | |
Value | Meaning | |
0 | Call was not redirected. | |
1 | Station was busy. | |
7 | Call was within a hunt group. | |
9 | Station was out of order. | |
15 | Call was redirected. | |
X.25 D-BIT CONFIRMATION | ||
Type: | Configuration | |
Format: | AT [cmds] %B7=n [cmds] | |
Description: | Enablbes/disables X.25 D-bit confirmation | |
Command | Function | |
í %B7=0 | X.25 D-bit confirmation disabled. | |
%B7=1 | X.25 D-bit confirmation enabled. | |
X.25 LOGICAL CHANNEL | |
Type: | Configuration |
Format: | AT [cmds] %B6=n [cmds] |
Default: | 1 |
Range: | 0 - 255 |
Unit: | Unidentified |
Description: | Selects the logical channel for X.25 operation. |
X.25 PACKET CALL TIMER | |
Type: | Configuration |
Format: | AT [cmds] %B98=n [cmds] |
Default: | 180 |
Range: | 0 - 600 |
Unit: | Unidentified |
Description: | Sets the packet call timer for X.25 operation. |
X.25 OUTGOING CALL ADDRESS | |
Type: | Configuration |
Format: | AT [cmds] %B17=nnnn [cmds] |
Default: | 0 |
Range: | 0 - 15 |
Unit: | Unidentified |
Description: | Sets the address for an outgoing X.25 virtual call. |
X.25 PVC | ||
Type: | Configuration | |
Format: | AT [cmds] %B5=n [cmds] | |
Description: | Selects whether X.25 will use Permanent Virtual Channel. | |
Command | Function | |
í %B5=0 | X.25 PVC disabled. | |
%B5=1 | X.25 PVC enabled. | |
X.25 RECEIVE PACKET SIZE | |
Type: | Configuration |
Format: | AT [cmds] %B2=n [cmds] |
Default: | 0 |
Range: | 0, 7 - 10 |
Unit: | Unidentified |
Description: | Sets the size of the received packets for X.25. |
X.25 RECEIVE THROUGHPUT | ||
Type: | Configuration | |
Format: | AT [cmds] %B11=n [cmds] | |
Description: | Sets the throughput for receiving X.25. | |
Command | Function | |
í %B11=0 | Use network speed. | |
%B11=3 | Throughput set to 75bps. | |
%B11=4 | Throughput set to 110bps. | |
%B11=5 | Throughput set to 300bps. | |
%B11=6 | Throughput set to 600bps. | |
%B11=7 | Throughput set to 1200bps. | |
%B11=8 | Throughput set to 2400bps. | |
%B11=9 | Throughput set to 4800bps. | |
%B11=10 | Throughput set to 9600bps. | |
%B11=11 | Throughput set to 19.2Kbps. | |
%B11=12 | Throughput set to 48Kbps. | |
%B11=13 | Throughput set to 64Kbps. | |
X.25 RECEIVE WINDOW SIZE | |
Type: | Configuration |
Format: | AT [cmds] %B0=n [cmds] |
Default: | 0 |
Range: | 0 - 8 |
Unit: | Unidentified |
Description: | Sets the size of the X.25 receive window. |
X.25 RESET CODE | ||
Type: | Read-only | |
Format: | AT [cmds] %B20 [cmds] | |
Description: | Reports the reason for an X.25 reset. | |
Value | Meaning | |
0 | Normal operation - no reset has occurred. | |
1 | DTE caused reset. | |
2 | Local procedure error occurred. | |
3 | Destination address is incompatible. | |
4 | Network is busy. | |
5 | Remote procedure error occurred. | |
6 | Cause of reset unknown. | |
X.25 RESET TIMER | |
Type: | Configuration |
Format: | AT [cmds] %B99=n [cmds] |
Default: | 180 |
Range: | 0 - 600 |
Unit: | Unidentified |
Description: | Sets the reset timer for X.25 operation. |
X.25 RPOA | |
Type: | Configuration |
Format: | AT [cmds] %B14=xxxx [cmds] |
Default: | 0000 |
Range: | 0 - 16 |
Unit: | Unidentified |
Description: | Sets the RPOA for X.25. |
X.25 TRANSMIT DELAY | |
Type: | Configuration |
Format: | AT [cmds] %B19=n [cmds] |
Default: | 0 |
Range: | 0 - 65535 |
Unit: | 1ms |
Description: | Sets the delay time for X.25 transmission. |
X.25 TRANSMIT PACKET SIZE | |
Type: | Configuration |
Format: | AT [cmds] %B3=n [cmds] |
Default: | 0 |
Range: | 0, 7 - 10 |
Unit: | Unidentified |
Description: | Sets the size of the transmitted packets for X.25. |
X.25 TRANSMIT THROUGHPUT | ||
Type: | Configuration | |
Format: | AT [cmds] %B12=n [cmds] | |
Description: | Sets the throughput for transmitting X.25. | |
Command | Function | |
í %B12=0 | Use network speed. | |
%B12=3 | Throughput set to 75bps. | |
%B12=4 | Throughput set to 110bps. | |
%B12=5 | Throughput set to 300bps. | |
%B12=6 | Throughput set to 600bps. | |
%B12=7 | Throughput set to 1200bps. | |
%B12=8 | Throughput set to 2400bps. | |
%B12=9 | Throughput set to 4800bps. | |
%B12=10 | Throughput set to 9600bps. | |
%B12=11 | Throughput set to 19.2Kbps. | |
%B12=12 | Throughput set to 48Kbps. | |
%B12=13 | Throughput set to 64Kbps. | |
X.25 TRANSMIT WINDOW SIZE | |
Type: | Configuration |
Format: | AT [cmds] %B1=n [cmds] |
Default: | 0 |
Range: | 0 - 8 |
Unit: | Unidentified |
Description: | Sets the size of the X.25 transmit window. |
X.25 USER DATA | |
Type: | Configuration |
Format: | AT [cmds] %B18=xxxx [cmds] |
Default: | 0000 |
Range: | 0 - 12 |
Unit: | Unidentified |
Description: | Sets miscellaneous user data for X.25. |
X.25 USER ID | |
Type: | Configuration |
Format: | AT [cmds] %B13=xxxx [cmds] |
Default: | 0 |
Range: | 0 - 16 |
Unit: | Unidentified |
Description: | Sets the network user ID for X.25. |
X.3 PAD ANCILLARY DEVICE | ||
Type: | Configuration | |
Format: | AT [cmds] %L5=n [cmds] | |
Description: | Selects control of an ancillary device by the PAD. | |
Command | Function | |
%L5=0 | Device disabled. | |
í %L5=1 | Device enabled for data transfer only. | |
%L5=2 | Device enabled for data transfer and command control. | |
X.3 PAD BREAK RESPONSE | ||
Type: | Configuration | |
Format: | AT [cmds] %L7=n [cmds] | |
Description: | Sets action the PAD takes in response to receiving a BREAK from the DTE. | |
Command | Function | |
%L7=0 | Response disabled | |
%L7=1 | Send interrupt packet | |
%L7=2 | Send reset packet | |
%L7=5 | Send interrupt and indication of break packets | |
%L7=8 | Escape from data state | |
%L7=21 | Send interrupt and indication of break packets and set %L8 to 1 | |
X.3 PAD - CARRIAGE RETURN PADDING | |
Type: | Configuration |
Format: | AT [cmds] %L9=n [cmds] |
Default: | 0 |
Range: | 0 - 255 |
Unit: | Unidentified |
Description: | Sets the amount of padding after a carriage return. |
X.3 PAD CARRIAGE RETURN TRANSLATION | |||
Type: | Configuration | ||
Format: | AT [cmds] %L13=n [cmds] | ||
Default: | 0 | ||
Range: | 0 - 7 | ||
Description: | Selects when the PAD will add line feeds to carriage returns. | ||
Bit | Value | Function | |
0 | 0 í 1 | PAD will not add a line feed after a carriage return being sent to the DTE. PAD will add a line feed after a carriage return being sent to the DTE. | |
1 | í 01 | PAD will not add a line feed after a carriage return being received from the DTE. PAD will add a line feed after a carriage return being received from the DTE. | |
2 | 0 í 1 | PAD will not add a line feed after a carriage return being echoed. PAD will add a line feed after a carriage return being echoed. | |
X.3 PAD CHARACTER DELETE | |
Type: | Configuration |
Format: | AT [cmds] %L16=n [cmds] |
Default: | 8 |
Range: | 0 - 127 |
Unit: | 1 ASCII character |
Description: | Sets the character used for character deletion. |
X.3 PAD DATA EDITING | ||
Type: | Configuration | |
Format: | AT [cmds] %L15=n [cmds] | |
Description: | Selects whether editing the data being transferred is allowed. | |
Command | Function | |
%L15=0 | Editing disabled. | |
%L15=1 | Editing enabled. | |
X.3 PAD DISCARD DATA | ||
Type: | Configuration | |
Format: | AT [cmds] %L8=n [cmds] | |
Description: | Selects whether the PAD will deliver data to the DTE. | |
Command | Function | |
í %L8=0 | Deliver data to the DTE. | |
%L8=1 | Discard data. | |
X.3 PAD - DTE SPEED | ||
Type: | Configuration | |
Format: | AT [cmds] %L11=n [cmds] | |
Description: | Sets the speed of operation for the serial port when using the X.25 PAD. | |
Command | Function | |
%L11=2 | Set serial port speed to 300bps. | |
%L11=3 | Set serial port speed to 1200bps. | |
%L11=4 | Set serial port speed to 600bps. | |
%L11=12 | Set serial port speed to 2400bps. | |
%L11=13 | Set serial port speed to 4800bps. | |
%L11=14 | Set serial port speed to 9600bps. | |
%L11=15 | Set serial port speed to 19.2Kbps. | |
í %L11=16 | Set serial port speed to 38.4Kbps. | |
X.3 PAD ECHO | ||
Type: | Configuration | |
Format: | AT [cmds] %L2=n [cmds] | |
Description: | Selects whether PAD functions will echo incoming characters. | |
Command | Function | |
%L2=0 | PAD echo disabled. | |
í %L2=1 | PAD echo enabled. | |
X.3 PAD ECHO MASK | |||
Type: | Configuration | ||
Format: | AT [cmds] %L20=n [cmds] | ||
Default: | 248 | ||
Range: | 0 - 255 | ||
Description: | Selects which control characters will be echoed. | ||
Bit | Value | Function | |
0 | í 01 | Carriage return will be echoed. Carriage return will not be echoed. | |
1 | í 01 | Line feed will be echoed. Line feed will not be echoed. | |
2 | í 01 | The control characters VT, HT, and form feeds will be echoed. The control characters VT, HT, and form feeds will not be echoed. | |
3 | 0 í 1 | Bells and backspaces will be echoed. Bells and backspaces will not be echoed. | |
4 | 0 í 1 | The control character ENQ and escapes will be echoed. The control character ENQ and escapes will not be echoed. | |
5 | 0 í 1 | The control characters ACK, NAK, STX, SOH, EOT, ETB, and ETX will be echoed. The control characters ACK, NAK, STX, SOH, EOT, ETB, and ETX will not be echoed. | |
6 | 0 í 1 | Parameters 16, 17, and 18 will be echoed. Parameters 16, 17, and 18 will not be echoed. | |
7 | 0 í 1 | All other control characters will be echoed. All other control characters will not be echoed. | |
X.3 PAD FLOW CONTROL | ||
Type: | Configuration | |
Format: | AT [cmds] %L12=n [cmds] | |
Description: | Selects flow control for the X.25 PAD. | |
Command | Function | |
%L12=0 | Flow control disabled. | |
%L12=1 | Flow control enabled. | |
X.3 PAD FORWARDING | |||
Type: | Configuration | ||
Format: | AT [cmds] %L3=n [cmds] | ||
Default: | 2 | ||
Range: | 0 - 127 | ||
Description: | Selects which characters will be forwarded through the PAD. | ||
Bit | Value | Function | |
0 | í 01 | Alphanumeric characters will not be forwarded. Alphanumeric characters (A-Z, a-z, 0-9) will be forwarded. | |
1 | 0 í 1 | Carriage returns will not be forwarded. Carriage returns will be forwarded. | |
2 | í 01 | The control characters ENQ, ACK, bells, and escapes will not be forwarded. The control characters ENQ, ACK, bells, and escapes will be forwarded. | |
3 | í 01 | The control characters CAN, DC2, and delete will not be forwarded. The control characters CAN, DC2, and delete will be forwarded. | |
4 | í 01 | The control characters ETX and EOT will not be forwarded. The control characters ETX and EOT will be forwarded. | |
5 | í 01 | The control characters HT, LT, VT, and form feeds will not be forwarded. The control characters HT, LT, VT, and FF will be forwarded. | |
6 | í 01 | All other control characters will not be forwarded. All other control characters will be forwarded. | |
X.3 PAD IDLE TIME | |
Type: | Configuration |
Format: | AT [cmds] %L4=n [cmds] |
Default: | 0 |
Range: | 0 - 255 |
Unit: | Unidentified |
Description: | Sets the PAD’s idle time delay. |
X.3 PAD LINE DELETE | |
Type: | Configuration |
Format: | AT [cmds] %L17=n [cmds] |
Default: | 24 |
Range: | 0 - 127 |
Unit: | 1 ASCII character |
Description: | Sets the character used for line deletion. |
X.3 PAD LINE DISPLAY | |
Type: | Configuration |
Format: | AT [cmds] %L18=n [cmds] |
Default: | 18 |
Range: | 0 - 127 |
Unit: | 1 ASCII character |
Description: | Sets the character used for line display. |
X.3 PAD - LINE FEED PADDING | |
Type: | Configuration |
Format: | AT [cmds] %L14=n [cmds] |
Default: | 0 |
Range: | 0 - 255 |
Unit: | Unidentified |
Description: | Sets the amount of padding after a line feed. |
X.25 PAD - LINE WRAP | |
Type: | Configuration |
Format: | AT [cmds] %L10=n [cmds] |
Default: | 0 |
Range: | 0 - 255 |
Unit: | 1 character |
Description: | Sets the length of a line for the X.25 PAD. |
X.3 PAD PAGE WAIT | |
Type: | Configuration |
Format: | AT [cmds] %L22=n [cmds] |
Default: | 0 |
Range: | 0 - 255 |
Unit: | Unidentified |
Description: | Sets the amount of padding after a form feed. |
X.3 PAD PARITY | ||
Type: | Configuration | |
Format: | AT [cmds] %L21=n [cmds] | |
Description: | Selects the format of the parity bit. | |
Command | Function | |
í %L21=0 | No parity. | |
%L21=3 | Use setting in @P3. | |
X.3 PAD RECALL | |
Type: | Configuration |
Format: | AT [cmds] %L1=n [cmds] |
Default: | 0 |
Range: | 0, 1, 32 - 126 |
Unit: | ASCII |
Description: | Sets the character for PAD recall. %L1=0 disables recall, %L1=1 selects DLE control character. |
X.3 PAD SERVICE SIGNALS | ||
Type: | Configuration | |
Format: | AT [cmds] %L6=n [cmds] | |
Description: | Selects which PAD service signals will be sent to the user. | |
Command | Function | |
%L6=0 | No signals will be sent. | |
%L6=1 | All signals except prompt will be sent. | |
%L6=5 | All signals will be sent. | |
X.3 PAD SERVICE SIGNAL DESTINATION | ||
Type: | Configuration | |
Format: | AT [cmds] %L19=n [cmds] | |
Description: | Selects where PAD service signals will be sent. | |
Command | Function | |
%L19=0 | Signals will not be sent. | |
%L19=1 | Signals will be sent to the printer. | |
í %L19=2 | Signals will be sent to the monitor. | |
Special Commands
COMMAND SET | ||
Type: | Configuration | |
Format: | AT [cmds] @P1=x [cmds] | |
Description: | Selects the command set that will be used. | |
Command | Function | |
@P1=A | AT command set enabled. | |
@P1=E | EIA-366 enabled | |
@P1=N | Command sets disabled. | |
@P1=VB | V.25bis command set enabled in Bisync mode. | |
@P1=VH | V.25bis command set enabled in HDLC mode. | |
CONTROL PORT SELECTION | ||
Type: | Immediate | |
Format: | AT [cmds] >Cn [cmds] | |
Description: | Selects control port | |
Command | Function | |
>C0 | Exits control mode | |
>C1 | Control port 1 enabled | |
>C2 | Control port 2 enabled | |
>C3 | Control port 3 enabled | |
>C4 | Control port 4 enabled | |
DATA LENGTH | ||
Type: | Configuration | |
Format: | AT [cmds] @P4=n [cmds] | |
Description: | Selects the length of the data word. | |
Command | Function | |
@P4=7 | 7 bit word length. | |
í @P4=8 | 8 bit word length. | |
DATA PARITY | ||
Type: | Configuration | |
Format: | AT [cmds] @P3=x [cmds] | |
Description: | Selects the format of the parity bit. | |
Command | Function | |
í @P3=E | Even parity. | |
@P3=M | Mark parity. | |
@P3=N | No parity. | |
@P3=O | Odd parity. | |
DATA STOP | ||
Type: | Configuration | |
Format: | AT [cmds] @P6=n [cmds] | |
Description: | Selects the number of stop bits. | |
Command | Function | |
í @P6=0 | One stop bit. | |
@P6=1 | One and a half stop bits. | |
@P6=2 | Two stop bits. | |
DIRECTORY NUMBER | |
Type: | Configuration |
Format: | AT !N= <#> |
Default: | 0 |
Range: | 0 - 20 |
Description: | Sets the directory number by port |
DISPLAY CONFIGURATION | ||
Type: | Immediate | |
Format: | AT [cmds] >V=x [cmds] | |
Description: | Displays information about the current configuration. | |
Command | Function | |
>V=C | Displays directory numbers, SPIDs, and TEIs. | |
>V=G | Displays global parameters. | |
FRONT PANEL LOCK | ||
Type: | Configuration | |
Format: | AT [cmds] >Fn [cmds] | |
Description: | Prevents front panel configuration changes. | |
Command | Function | |
í >F0 | All actions allowed from front panel. | |
>F1 | Configuration changes from front panel not allowed. | |
>F2 | No actions allowed from front panel. | |
LOCAL SERIAL PORT SPEED | ||
Type: | Configuration | |
Format: | AT [cmds] @P2=n [cmds] | |
Description: | Sets the speed of operation for the serial port. Speeds higher than 38.4Kbps disables autobaud | |
Note: | Spee can be entered using command code or by entering the bit rate value | |
Command | Function | |
@P2=3 | Set serial port speed to 300bps. | |
@P2=5 | Set serial port speed to 1200bps. | |
@P2=6 | Set serial port speed to 2400bps. | |
@P2=7 | Set serial port speed to 4800bps. | |
@P2=9 | Set serial port speed to 9600bps. | |
@P2=12 | Set serial port speed to 19.2Kbps. | |
í @P2=13 | Set serial port speed to 38.4Kbps. | |
@P2=17 | Set serial port speed to 56.0Kbps. | |
@P2=18 | Set serial port speed to 57.6Kbps. | |
@P2=19 | Set serial port speed to 64.0Kbps. | |
@P2=20 | Set serial port speed to 112.0Kbps. | |
@P2=21 | Set serial port speed to 128.0Kbps. | |
@P2=22 | Set serial port speed to 115.2Kbps. | |
@P2=32 | Set serial port speed to 48.0Kbps. | |
SPID NUMBER | |
Type: | Configuration |
Format: | AT [cmds] !C2=n [cmds] |
Default: | 0 |
Range: | 0 - 20 |
Unit: | Unidentified |
Description: | Sets the SPID number associated with a particular port |
SWITCH TYPE | ||
Type: | Configuration | |
Format: | AT [cmds] !C0=n [cmds] | |
Description: | Selects what type of network switch the TA is connected to. | |
Command | Function | |
!C0=0 | TA is connected to 5ESS switch. | |
!C0=1 | TA is connected to DMS-100 switch. | |
í !C0=2 | TA is connected to NI-1 switch. | |
SWITCH VERSION | ||
Type: | Configuration | |
Format: | AT [cmds] !C1=n [cmds] | |
Description: | Selects what version of network switch the TA is connected to. | |
Command | Function | |
!C1=0 | TA is connected to point-to-point 5ESS switch. | |
!C1=1 | TA is connected to multipoint 5ESS switch. | |
!C1=2 | TA is connected to IC-0 DMS-100 switch. | |
!C1=3 | TA is connected to IC-1 DMS-100 switch. | |
í !C1=4 | TA is connected to NI-1 switch. | |
TEI DATA SET | |
Type: | Configuration |
Format: | AT [cmds] !D3=n [cmds] |
Default: | 127 |
Range: | 0 - 63, 255 |
Description: | Determines data Terminal Endpoint Identifier. !D3=127 disables function. !D3=255 sets parameter to auto |
TEI X.25 SET | |
Type: | Configuration |
Format: | AT [cmds] !D0=n [cmds] |
Default: | 127 |
Range: | 0 - 63, 255 |
Description: | Determines the Terminal Endpoint Identifier for X.25. !D0=127 disables function. !D0=255 sets parameter to auto |
TEST MODES | ||
Type: | Configuration | |
Format: | AT [cmds] >Tn [cmds] | |
Description: | Enables/disables test modes. | |
Command | Function | |
>T0 | End test | |
>T4 | 2B+D loopback | |
TLINK DTR | ||
Type: | Configuration | |
Format: | AT [cmds] @T1=x [cmds] | |
Description: | Controls data terminal ready function in TLink mode | |
Command | Function | |
@T1=A | DTR forced high | |
í @T1=N | DTR normal | |
TLINK ECHO | ||
Type: | Configuration | |
Format: | AT [cmds] @T0=x [cmds] | |
Description: | Enables/disables TLink echo function | |
Command | Function | |
@T0=E | TLink echo function enabled | |
í @T0=D | TLink echo function disabled | |
TLINK NEGOTIATION | ||
Type: | Configuration | |
Format: | AT [cmds] @T3=x [cmds] | |
Description: | Enables/disables TLink negotiation | |
Command | Function | |
í @T3=E | TLink negotiation enabled | |
@T3=D | TLink negotiation disabled | |
TLINK RTS | ||
Type: | Configuration | |
Format: | AT [cmds] @T1=x [cmds] | |
Description: | Controls request to send function in TLink mode | |
Command | Function | |
@T2=A | RTS forced high | |
í @T2=N | RTS normal | |
WRITE PROTECT | ||
Type: | Configuration | |
Format: | AT [cmds] @G=x [cmds] | |
Description: | Selects the ability to prevent permanent changes to the TA’s configuration from being made. All changes made in temporary memory will be reset at the end of every call. | |
Command | Function | |
í @G=D | Write protect disabled. | |
@G=E | Write protect enabled. | |
X.25 D-CHANNEL | ||
Type: | Configuration | |
Format: | AT [cmds] !C3=n [cmds] | |
Description: | Selects whether X.25 will be used on the D-channel. | |
Command | Function | |
í !C3=0 | X.25 disabled on D-channel. | |
!C3=1 | X.25 enabled on D-channel. | |
X.25 D-CHANNEL - CHANNELS, BIDIRECTIONAL | |
Type: | Configuration |
Format: | AT [cmds] !X6=n [cmds] |
Default: | 8 |
Range: | 0 - 255 |
Unit: | Unidentified |
Description: | Sets the number of bidirectional logical channels for X.25. |
X.25 D-CHANNEL - CHANNELS, INCOMING | |
Type: | Configuration |
Format: | AT [cmds] !X5=n [cmds] |
Default: | 0 |
Range: | 0 - 255 |
Unit: | Unidentified |
Description: | Sets the number of incoming logical channels for X.25. |
X.25 D-CHANNEL - CHANNELS, OUTGOING | |
Type: | Configuration |
Format: | AT [cmds] !X7=n [cmds] |
Default: | 0 |
Range: | 0 - 255 |
Unit: | Unidentified |
Description: | Sets the number of outgoing logical channels for X.25. |
X.25 D-CHANNEL - CHANNELS, VIRTUAL | |
Type: | Configuration |
Format: | AT [cmds] !X4=n [cmds] |
Default: | 0 |
Range: | 0 - 255 |
Unit: | Unidentified |
Description: | Sets the number of permanent virtual channels for X.25. |
X.25 D-CHANNEL - MODULUS | |
Type: | Configuration |
Format: | AT [cmds] !X8=n [cmds] |
Default: | 8 |
Range: | 8, 128 |
Unit: | Unidentified |
Description: | Sets the sequence modulus for X.25. |
X.25 D-CHANNEL - NEGOTIATION | ||
Type: | Configuration | |
Format: | AT [cmds] !D1=n [cmds] | |
Description: | Selects X.25 parameter negotiation. | |
Command | Function | |
!D1=0 | X.25 negotiation disabled. | |
í !D1=1 | X.25 negotiation enabled. | |
X.25 D-CHANNEL - RECEIVE PACKET SIZE | ||
Type: | Configuration | |
Format: | AT [cmds] !X2=n [cmds] | |
Description: | Sets the size of the received packets for X.25. | |
Command | Function | |
í !X2=7 | Packet size set to 128 bytes. | |
!X2=8 | Packet size set to 256 bytes. | |
X.25 D-CHANNEL - RECEIVE WINDOW SIZE | |
Type: | Configuration |
Format: | AT [cmds] !X0=n [cmds] |
Default: | 2 |
Range: | 1 - 7 |
Unit: | N/A |
Description: | Sets the size of the X.25 receive window. |
X.25 D-CHANNEL - TRANSMIT PACKET SIZE | ||
Type: | Configuration | |
Format: | AT [cmds] !X3=n [cmds] | |
Description: | Sets the size of the transmitted packets for X.25. | |
Command | Function | |
í !X3=7 | Packet size set to 128 bytes. | |
!X3=8 | Packet size set to 256 bytes. | |
X.25 D-CHANNEL - TRANSMIT WINDOW SIZE | |
Type: | Configuration |
Format: | AT [cmds] !X1=n [cmds] |
Default: | 2 |
Range: | 1 - 7 |
Unit: | N/A |
Description: | Sets the size of the X.25 transmit window. |