MOTOROLA, INC.
HMTA 200 V.32BIS
Card Type | ISDN TA |
Chip Set | Motorola |
ISDN Transfer Rate | 64Kbps x 2 |
Maximum Modem Rate | 14.4Kbps |
Maximum Fax Rate | 14.4Kbps |
Fax Class | Unidentified |
Data Bus | External |
ISDN Protocol | V.120, PPP, AIMux, Bonding |
Data Modulation Protocol | Bell 103A/212A ITU-T V.21, V.22bis, V.23, V.32, V.32bis |
Fax Modulation Protocol | Unidentified |
Switch Type | 5ESS, DMS-100, NI-1 |
Error Correction/Compression | MNP5, V.42bis |
Proprietary AT Command Set
V2152
AUTO-RELIABLE BUFFER | ||
Type: | Configuration | |
Format: | AT [cmds] \Cn [cmds] | |
Description: | Sets the behaviour of the buffer during auro-reliable negotiation. | |
Command | Function | |
í \C0 | Auto-reliable buffer disabled. | |
\C1 | Modem will buffer data for four seconds or 200 bytes. | |
\C2 | Modem will fall back to normal mode if fallback character received. | |
BEARER CALL - 3.1KHz AUDIO | ||
Type: | Configuration | |
Format: | AT [cmds] %A94=x [cmds] | |
Description: | Selects how the TA will answer an incoming 3.1KHz audio BC call. | |
Command | Function | |
%A94=D | TA will not answer 3.1KHz audio BC calls. | |
%A94=E | TA will answer 3.1KHz audio BC calls as ISDN. | |
í %A94=M | TA will answer 3.1KHz audio BC calls with the modem. | |
BEARER CALL - DATA | ||
Type: | Configuration | |
Format: | AT [cmds] %A95=x [cmds] | |
Description: | Selects how the TA will answer an incoming data BC call. | |
Command | Function | |
%A93=D | TA will not answer data BC calls. | |
í %A93=E | TA will answer data BC calls as ISDN. | |
%A93=M | TA will answer data BC calls with the modem. | |
BEARER CALL - SPEECH | ||
Type: | Configuration | |
Format: | AT [cmds] %A93=x [cmds] | |
Description: | Selects how the TA will answer an incoming speech BC call. | |
Command | Function | |
%A93=D | TA will not answer speech BC calls. | |
%A93=E | TA will answer speech BC calls as ISDN. | |
í %A93=M | TA will answer speech BC calls with the modem. | |
BREAK TYPE | |||||
Type: | Configuration | ||||
Format: | AT [cmds] \Kn [cmds] | ||||
Description: | Configures action of break signal. | ||||
Command | Break from DTE Reliable/Normal mode | Break from DTE Direct mode | Modem receives \B | Break from remote modem | |
\K0 | Enter command mode, do not send break to remote modem. | Send break to remote modem immediately, then enter command mode. | Buffers cleared and break sent to remote modem. | Buffers cleared and break sent to DTE. | |
\K1 | Buffers cleared and break sent to remote modem. | Send break to remote modem immediately. | Buffers cleared and break sent to remote modem. | Buffers cleared and break sent to DTE. | |
\K2 | Enter command mode, do not send break to remote modem. | Send break to remote modem immediately, then enter command mode. | Send break to remote modem immediately. | Send break to DTE immediately. | |
\K3 | Send break to remote modem immediately. | Send break to remote modem immediately. | Send break to remote modem immediately. | Send break to DTE immediately. | |
\K4 | Enter command mode, do not send break to remote modem. | Send break to remote modem immediately, then enter command mode. | Send break to remote modem with transmitted data. | Break sent with received data to the DTE. | |
í \K5 | Send break with transmitted data. | Send break to remote modem immediately. | Send break to remote modem with transmitted data. | Break sent with received data to the DTE. | |
CALLER ID | ||
Type: | Configuration | |
Format: | AT [cmds] @N0=n [cmds] | |
Description: | Enables the Caller ID function. | |
Command | Function | |
í @N0=0 | Caller ID disabled. | |
@N0=1 | Caller ID enabled. | |
CALLER ID LOG | ||
Type: | Immediate | |
Format: | AT [cmds] @Ln [cmds] | |
Description: | Allows the user to view and clear the Caller ID log. | |
Command | Function | |
@L0 | Clears the Caller ID log. | |
@L1 | View the last entry in the Caller ID log. | |
@L2 | View the last ten entries in the Caller ID log. | |
CD SIGNAL | ||
Type: | Configuration | |
Format: | AT [cmds] &Cn [cmds] | |
Description: | Controls the behaviour of the CD signal. | |
Command | Function | |
í &C0 | CD forced high. | |
&C1 | CD normal. | |
&C2 | CD forced low on disconnect. | |
COMMAND SET | ||
Type: | Configuration | |
Format: | AT [cmds] @P1=x [cmds] | |
Description: | Selects the command set that will be used. | |
Command | Function | |
@P1=A | AT command set enabled. | |
@P1=N | Command sets disabled. | |
@P1=VB | V.25bis command set enabled in Bisync mode. | |
@P1=VH | V.25bis command set enabled in HDLC mode. | |
COMPRESSION | ||
Type: | Configuration | |
Format: | AT [cmds] %Cn [cmds] | |
Description: | Selects how the modem will compress data. | |
Command | Function | |
%C0 | Compression disabled. | |
%C1 | Compression enabled. | |
%C2 | Compression enabled on transmit only. | |
%C3 | Compression enabled on receive only. | |
COMPRESSION/ERROR CORRECTION MODE | ||
Type: | Configuration | |
Format: | AT [cmds] \Nn [cmds] | |
Description: | Selects the types of compression and error correction that will be attempted. | |
Command | Function | |
\N0 | Normal mode only, compression and error correction disabled. | |
\N1 | Direct mode only, compression and error correction disabled. | |
\N2 | MNP attempted, modem will disconnect if MNP connection fails. | |
\N3 | MNP attempted, modem will attempt normal mode if MNP connection fails. | |
\N4 | LAPM attempted, modem will disconnect if LAPM connection fails. | |
\N5 | LAPM attempted, modem will attempt normal mode if LAPM connection fails. | |
\N6 | LAPM attempted, then MNP, modem will disconnect if both previous connections fail. | |
\N7 | LAPM attempted, then MNP, modem will attempt normal mode if both previous connections fail. | |
DATA LENGTH | ||
Type: | Configuration | |
Format: | AT [cmds] @P4=n [cmds] | |
Description: | Selects the length of the data word. | |
Command | Function | |
@P4=7 | 7 bit word length. | |
í @P4=8 | 8 bit word length. | |
DATA PARITY | ||
Type: | Configuration | |
Format: | AT [cmds] @P3=x [cmds] | |
Description: | Selects the format of the parity bit. | |
Command | Function | |
@P3=E | Even parity. | |
@P3=M | Mark parity. | |
í @P3=N | No parity. | |
@P3=O | Odd parity. | |
DATA STOP | ||
Type: | Configuration | |
Format: | AT [cmds] @P6=n [cmds] | |
Description: | Selects the number of stop bits. | |
Command | Function | |
í @P6=0 | One stop bit. | |
@P6=1 | One and a half stop bits. | |
@P6=2 | Two stop bits. | |
DIAL MODE | ||
Type: | Configuration | |
Format: | AT [cmds] %A97=x [cmds] | |
Description: | Selects what type of dialing the TA will use. | |
Command | Function | |
í %A97=E | En bloc dialing enabled. | |
%A97=O | Overlap dialing enabled. | |
DIRECTORY NUMBER 1 SET | |
Type: | Configuration |
Format: | AT !N1= <#>AT [cmds] !N1=" <#>" [cmds] |
Description: | Sets the first directory number. The number must be surrounded by single or double quotes if there are more commands on the line. |
DIRECTORY NUMBER 2 SET | |
Type: | Configuration |
Format: | AT !N2= <#>AT [cmds] !N2=" <#>" [cmds] |
Description: | Sets the first directory number. The number must be surrounded by single or double quotes if there are more commands on the line. |
DISCONNECT BUFFER TIME | |
Type: | Configuration |
Format: | AT [cmds] %Dn [cmds] |
Default: | 0 |
Range: | 0 - 255 |
Unit: | 1 second |
Description: | Sets the time that the modem will wait to disconnect if there is data in its buffers. |
DISPLAY CONFIGURATION | ||
Type: | Immediate | |
Format: | AT [cmds] >V=x [cmds] | |
Description: | Displays information about the current configuration. | |
Command | Function | |
>V=C | Displays directory numbers, SPIDs, and TEIs. | |
>V=G | Displays complete configuration. | |
DISPLAY CONFIGURATION | |
Type: | Immediate |
Format: | AT [cmds] &V=x[n] [cmds] |
Description: | Displays information about the current configuration. |
Command | Function |
&V | Displays current and stored profiles. |
&V=Bn | Displays X.25 session n. |
&V=E | Displays V.120 CSD information. |
&V=Ln | Displays local X.25 session n. |
&V=Rn | Displays remote X.25 session n. |
&V=Z | Displays stored phone numbers. |
DISPLAY FIRMWARE VERSION | |
Type: | Immediate |
Format: | AT [cmds] %Vn [cmds] |
Description: | Displays the version of the installed firmware. |
DISPLAY PRODUCT INFORMATION | |
Type: | Immediate |
Format: | AT [cmds] In [cmds] |
Description: | Displays information about the TA. |
Command | Function |
I0 | Displays product identification. |
I1 | Displays ROM checksum. |
I2 | Displays ROM checksum response. |
I3 | Displays firmware version. |
I4 | Displays modem capability in numeric form. |
I8 | Displays modem capability in verbose form. |
I9 | Displays Plug-And-Play ID. |
I10 | Displays ISDN link status. |
DTR AUTODIAL | ||
Type: | Configuration | |
Format: | AT [cmds] &Ln [cmds] | |
Description: | Causes the TA to repeatedly dial the first stored number on high DTR until it connects. | |
Command | Function | |
í &L0 | DTR autodialing disabled. | |
&L1 | DTR autodialing enabled. | |
DTR CHANGE TIME | |
Type: | Register |
Format: | AT [cmds] S25=n [cmds] |
Default: | 5 |
Range: | 0 - 255 |
Unit: | 10ms |
Description: | Sets the amount of time the DTR signal must be low before it is recognised. |
DTR SIGNAL | ||
Type: | Configuration | |
Format: | AT [cmds] &Dn [cmds] | |
Description: | Controls the behaviour of the DTR signal. | |
Command | Function | |
&D0 | DTR forced high. | |
&D1 | TA enters command mode when DTR goes low. | |
&D2 | TA hangs up and returns to command mode on low DTR. | |
&D3 | TA resets on low DTR. | |
&D9 | TA dials first stored number on high DTR, hangs up and returns to command mode on low DTR. | |
ECHO CANCELLER DISABLE | ||
Type: | Configuration | |
Format: | AT [cmds] %A96=n [cmds] | |
Description: | Selects whether the TA will send a tone to disable the echo canceller. | |
Command | Function | |
í %A96=0 | TA will not send echo canceller disable tone. | |
%A96=1 | TA will send echo canceller disable tone. | |
EXTENDED RESULT CODES - MODEM | ||
Type: | Configuration | |
Format: | AT [cmds] \Vn [cmds] | |
Description: | Selects which speed the modem will display for connect messages. | |
Command | Function | |
\V0 | Display serial port speed only. | |
\V1 | Display serial port speed and error correction protocol. | |
\V2 | Display line speed only. | |
\V3 | Display line speed and error correction protocol. | |
EXTENDED RESULT CODES - ISDN | ||
Type: | Configuration | |
Format: | AT [cmds] Wn [cmds] | |
Description: | Selects whether the TA will send extended protocol and channel result codes. | |
Command | Function | |
í W0 | Extended result codes disabled. | |
W1 | Extended result codes enabled. | |
FLOW CONTROL - MODEM-TO-MODEM | ||
Type: | Configuration | |
Format: | AT [cmds] \Gn [cmds] | |
Description: | Selects whether the local and remote modems may use flow control. | |
Command | Function | |
í \G0 | Modem-to-modem XON/XOFF flow control disabled. | |
\G1 | Modem-to-modem XON/XOFF flow control enabled. | |
FLOW CONTROL TYPE | ||
Type: | Configuration | |
Format: | AT [cmds] \Qn [cmds] | |
Description: | Selects the type of flow control that will be used. | |
Command | Function | |
\Q0 | Flow control disabled. | |
\Q1 | Bidirectional XON/XOFF flow control enabled. | |
\Q2 | CTS flow control enabled. | |
í \Q3 | RTS/CTS flow control enabled. | |
\Q4 | Unidirectional XON/XOFF flow control enabled. | |
Note: Unidirectional XON/XOFF is valid for ISDN operation only. If this mode is used while operating the modem it will not function properly. | ||
FRONT PANEL LOCK | ||
Type: | Configuration | |
Format: | AT [cmds] >Ln [cmds] | |
Description: | Prevents front panel configuration changes. | |
Command | Function | |
í >L0 | All actions allowed from front panel. | |
>L1 | Configuration changes from front panel not allowed. | |
>L2 | No actions allowed from front panel. | |
INACTIVITY TIMER | |
Type: | Configuration |
Format: | AT [cmds] \Tn [cmds] |
Default: | 0 |
Range: | 0 - 90 |
Unit: | 1 minute |
Description: | Sets the amount of time that the modem must be idle before it will disconnect. |
LINE SPEED - MAXIMUM | ||
Type: | Configuration | |
Format: | AT [cmds] %Bn [cmds] | |
Description: | Sets the maximum speed the modem will connect at. | |
Command | Function | |
%B0 | Modem will connect only at DCE speed. | |
%B300 | Modem will connect only at 300bps. | |
%B1200 | 1200bps maximum connect speed. | |
%B2400 | 2400bps maximum connect speed. | |
%B4800 | 4800bps maximum connect speed. | |
%B7200 | 7200bps maximum connect speed. | |
%B9600 | 9600bps maximum connect speed. | |
%B9600C | 9600bps maximum connect speed with trellis coding. | |
%B12000 | 12Kbps maximum connect speed. | |
í %B14400 | 14.4Kbps maximum connect speed. | |
LOAD STORED PROFILE | |
Type: | Immediate |
Format: | AT [cmds] Zn [cmds] |
Description: | Loads the configuration of the TA from the stored profile except for ISDN settings. |
LOAD STORED PROFILE - FULL | |
Type: | Immediate |
Format: | AT [cmds] >Zn [cmds] |
Description: | Loads the complete configuration of the TA from the stored profile. |
LOCAL SERIAL PORT SPEED | ||
Type: | Configuration | |
Format: | AT [cmds] @P2=n [cmds] | |
Description: | Sets the speed of operation for the serial port. | |
Command | Function | |
@P2=300 | Set serial port speed to 300bps. | |
@P2=600 | Set serial port speed to 600bps. | |
@P2=1200 | Set serial port speed to 1200bps. | |
@P2=2400 | Set serial port speed to 2400bps. | |
@P2=4800 | Set serial port speed to 4800bps. | |
@P2=7200 | Set serial port speed to 7200bps. | |
@P2=9600 | Set serial port speed to 9600bps. | |
@P2=12000 | Set serial port speed to 12Kbps. | |
@P2=14400 | Set serial port speed to 14.4Kbps. | |
@P2=19200 | Set serial port speed to 19.2Kbps. | |
@P2=28800 | Set serial port speed to 28.8Kbps. | |
@P2=38400 | Set serial port speed to 38.4Kbps. | |
@P2=48000 | Set serial port speed to 48Kbps. | |
@P2=56000 | Set serial port speed to 56Kbps. | |
í @P2=57600 | Set serial port speed to 57.6Kbps. | |
@P2=64000 | Set serial port speed to 64Kbps. | |
@P2=112000 | Set serial port speed to 112Kbps. | |
@P2=115200 | Set serial port speed to 115.2Kbps. | |
@P2=128000 | Set serial port speed to 128Kbps. | |
LOCK SERIAL PORT SPEED | ||
Type: | Configuration | |
Format: | AT [cmds] \Jn [cmds] | |
Description: | Selects whether the serial port speed will be matched to the line speed. | |
Command | Function | |
í \J0 | Serial port speed locked. | |
\J1 | Serial port speed will match line speed. | |
MNP BLOCK SIZE | ||
Type: | Configuration | |
Format: | AT [cmds] \An [cmds] | |
Description: | Sets the maximum size of a block in MNP mode. | |
Command | Function | |
\A0 | Maximum block size is 64 bytes. | |
\A1 | Maximum block size is 128 bytes. | |
\A2 | Maximum block size is 192 bytes. | |
\A3 | Maximum block size is 256 bytes. | |
ORIGINATE CALL - ISDN | ||
Type: | Configuration | |
Format: | AT [cmds] %A98=Ix [cmds] | |
Description: | Selects what bearer capability the TA will originate ISDN calls with. | |
Command | Function | |
%A98=I | Originate ISDN calls as data BC. | |
%A98=IA | Originate ISDN calls as 3.1KHz audio BC. | |
í %A98=ID | Originate ISDN calls as data BC. | |
%A98=IS | Originate ISDN calls as speech BC. | |
ORIGINATE CALL - MODEM | ||
Type: | Configuration | |
Format: | AT [cmds] %A98=Mx [cmds] | |
Description: | Selects what bearer capability the TA will originate modem calls with. | |
Command | Function | |
%A98=M | Originate modem calls as 3.1KHz audio BC. | |
í %A98=MA | Originate modem calls as 3.1KHz audio BC. | |
%A98=MD | Originate modem calls as data BC. | |
%A98=MS | Originate modem calls as speech BC. | |
PROTOCOL | ||
Type: | Configuration | |
Format: | AT [cmds] %A2=n [cmds] | |
Description: | Sets the protocol that the TA uses for rate adaptation. | |
Command | Function | |
%A2=0 | TA will use clear channel mode. | |
í %A2=2 | TA will use V.120 protocol. | |
%A2=3 | TA will use Bonding Mode 1 or AIMux protocols. | |
%A2=95 | TA will use PPP protocol. | |
RESET TO FACTORY DEFAULTS | |
Type: | Immediate |
Format: | AT [cmds] &F [cmds] |
Description: | Resets the configuration of the TA except for ISDN settings to the factory defaults. |
RESET TO FACTORY DEFAULT - FULL | |
Type: | Immediate |
Format: | AT [cmds] >F [cmds] |
Description: | Resets the complete configuration of the TA to the factory defaults. |
RETRAIN | ||
Type: | Immediate | |
Format: | AT [cmds] On | |
Description: | When connected, tells the modem to go back online and initiate a retrain. | |
Command | Function | |
O0 | Return online without retrain. | |
O1 | Return online with retrain. | |
O4800 | Return online and negotiate to 4800bps. | |
O7200 | Return online and negotiate to 7200bps. | |
O9600 | Return online and negotiate to 9600bps. | |
O12000 | Return online and negotiate to 12Kbps. | |
O14400 | Return online and negotiate to 14.4Kbps. | |
SPID 1 SET | |
Type: | Configuration |
Format: | AT !C6= <#>AT [cmds] !C6=" <#>" [cmds] |
Description: | Sets the first SPID. The SPID must be surrounded by single or double quotes if there are more commands on the line. |
SPID 2 SET | |
Type: | Configuration |
Format: | AT !C7= <#>AT [cmds] !C7=" <#>" [cmds] |
Description: | Sets the second SPID. The SPID must be surrounded by single or double quotes if there are more commands on the line. |
SWITCH TYPE | ||
Type: | Configuration | |
Format: | AT [cmds] !C0=n [cmds] | |
Description: | Selects what type of network switch the TA is connected to. | |
Command | Function | |
!C0=0 | TA is connected to 5ESS switch. | |
!C0=1 | TA is connected to DMS-100 switch. | |
í !C0=2 | TA is connected to NI-1 switch. | |
SWITCH VERSION | ||
Type: | Configuration | |
Format: | AT [cmds] !C1=n [cmds] | |
Description: | Selects what version of network switch the TA is connected to. | |
Command | Function | |
!C1=0 | TA is connected to point-to-point 5ESS switch. | |
!C1=1 | TA is connected to multipoint 5ESS switch. | |
!C1=2 | TA is connected to IC-0 DMS-100 switch. | |
!C1=3 | TA is connected to IC-1 DMS-100 switch. | |
í !C1=4 | TA is connected to NI-1 switch. | |
SYNC/ASYNC MODE | ||
Type: | Configuration | |
Format: | AT [cmds] &Mn [cmds] | |
Description: | Selects whether the DTE will be operation in synchronous or asynchronous mode. | |
Command | Function | |
í &M0 | DTE in asynchronous mode. | |
&M1 | DTE in asynchronous mode for dialing, synchronous mode for communications. | |
&M2 | DTE in synchronous mode, TA dials stored number on high DTR. | |
TEI 1 SET | ||
Type: | Configuration | |
Format: | AT [cmds] !D3=n [cmds] | |
Description: | Sets the first Terminal Endpoint Identifier. | |
Command | Function | |
!D3=0 ... !D3=63 | Sets the TEI to the value indicated. | |
!D3=127 | Disables channel 1. | |
í !D3=255 | Allows dynamic TEI assignment. | |
TEI 2 SET | ||
Type: | Configuration | |
Format: | AT [cmds] !D4=n [cmds] | |
Description: | Sets the second Terminal Endpoint Identifier. | |
Command | Function | |
!D4=0 ... !D4=63 | Sets the TEI to the value indicated. | |
í !D4=127 | Disables channel 2. | |
!D4=255 | Allows dynamic TEI assignment. | |
TEI X.25 SET | ||
Type: | Configuration | |
Format: | AT [cmds] !D0=n [cmds] | |
Description: | Sets the Terminal Endpoint Identifier for X.25. | |
Command | Function | |
!D0=0 ... !D0=63 | Sets the TEI to the value indicated. | |
í !D0=127 | Disables X.25 operation. | |
TRANSMISSION SPEED | ||
Type: | Configuration | |
Format: | AT [cmds] %A4=n [cmds] | |
Description: | Sets the transmission speed of the TA. | |
Command | Function | |
%A4=0 | Transmission speed is 64Kbps. | |
%A4=1 | Transmission speed is 56Kbps. | |
TRELLIS CODING | ||
Type: | Configuration | |
Format: | AT [cmds] Bn [cmds] | |
Description: | Selects whether trellis coding will be used at 9600bps. | |
Command | Function | |
í B2 | Trellis coding enabled. | |
B3 | Trellis coding disabled. | |
V.120 RECEIVE FRAME SIZE | |
Type: | Configuration |
Format: | AT [cmds] %E1=n [cmds] |
Default: | 256 |
Range: | 1 - 260 |
Unit: | 1 byte |
Description: | Sets the maximum size of a received V.120 frame. |
V.120 TRANSMIT FRAME SIZE | |
Type: | Configuration |
Format: | AT [cmds] %E0=n [cmds] |
Default: | 256 |
Range: | 1 - 260 |
Unit: | 1 byte |
Description: | Sets the maximum size of a transmitted V.120 frame. |
V.120 TRANSMIT TIMER | |
Type: | Configuration |
Format: | AT [cmds] %E3=n [cmds] |
Default: | 10 |
Range: | 1 - 255 |
Unit: | Unidentified |
Description: | Sets the V.120 T200 transmission timer. |
V.120 WINDOW SIZE | |
Type: | Configuration |
Format: | AT [cmds] %E2=n [cmds] |
Default: | 8 |
Range: | 1 - 127 |
Unit: | N/A |
Description: | Sets the size of the V.120 window. |
V.42 FAST DETECT | ||
Type: | Configuration | |
Format: | AT [cmds] \Mn [cmds] | |
Description: | Selects the normal or fast negotiation sequence for V.42. | |
Command | Function | |
\M0 | V.42 fast detect disabled. | |
í \M1 | V.42 fast detect enabled. | |
WRITE PROTECT | ||
Type: | Configuration | |
Format: | AT [cmds] @G=x [cmds] | |
Description: | Selects the ability to prevent permanent changes to the TA’s configuration from being made. All changes made in temporary memory will be reset at the end of every call. | |
Command | Function | |
í @G=D | Write protect disabled. | |
@G=E | Write protect enabled. | |
WRITE TO STORED PROFILE | |
Type: | Immediate |
Format: | AT [cmds] &Wn [cmds] |
Description: | Saves the configuration of the TA except for ISDN settings to stored profile n. |
WRITE TO STORED PROFILE - FULL | |
Type: | Immediate |
Format: | AT [cmds] >Wn [cmds] |
Description: | Saves the complete configuration of the TA to stored profile n. |
X.25 AUTO-ANSWER | ||
Type: | Configuration | |
Format: | AT [cmds] %B97=x [cmds] | |
Description: | Sets whether the TA will auto-answer an incoming X.25 virtual call. | |
Command | Function | |
%B97=D | Auto-answer disabled. | |
í %B97=E | Auto-answer enabled. | |
X.25 CALL CHARGING | ||
Type: | Configuration | |
Format: | AT [cmds] %B10=n [cmds] | |
Description: | Sets the type of call charging for X.25. | |
Command | Function | |
í %B10=0 | X.25 will use normal call charging. | |
%B10=1 | X.25 will use reverse call charging. | |
X.25 CLOSED USER GROUP | ||
Type: | Configuration | |
Format: | AT [cmds] %B8=n [cmds] | |
Description: | Selects the type of Closed User Group used for X.25. | |
Command | Function | |
í %B8=0 | CUG not used. | |
%B8=1 | Basic CUG used. | |
%B8=2 | CUG with outgoing access only used. | |
%B8=3 | CUG will full access used. | |
X.25 CLOSED USER GROUP ID | |
Type: | Configuration |
Format: | AT [cmds] %B9=nnnn [cmds] |
Description: | Sets the ID for the X.25 CUG. |
X.25 CODE - INCOMING | ||
Type: | Read-only | |
Format: | AT [cmds] %B16? [cmds] | |
Description: | Stores the result code for incoming X.25 virtual calls. | |
Value | Meaning | |
0 | Call was not redirected. | |
1 | Station was busy. | |
9 | Station was out of order. | |
15 | Call was redirected. | |
X.25 CODE - OUTGOING | ||
Type: | Immediate | |
Format: | AT [cmds] %B15? [cmds] | |
Description: | Stores the result code for outgoing X.25 virtual calls. | |
Value | Meaning | |
0 | Call was not redirected. | |
1 | Station was busy. | |
7 | Call was within a hunt group. | |
9 | Station was out of order. | |
15 | Call was redirected. | |
X.25 D-CHANNEL | ||
Type: | Configuration | |
Format: | AT [cmds] !C3=n [cmds] | |
Description: | Selects whether X.25 will be used on the D-channel. | |
Command | Function | |
í !C3=0 | X.25 disabled on D-channel. | |
!C3=1 | X.25 enabled on D-channel. | |
X.25 D-CHANNEL - CHANNELS, BIDIRECTIONAL | |
Type: | Configuration |
Format: | AT [cmds] !X6=n [cmds] |
Default: | 8 |
Range: | 0 - 255 |
Unit: | N/A |
Description: | Sets the number of bidirectional logical channels for X.25. |
X.25 D-CHANNEL - CHANNELS, INCOMING | |
Type: | Configuration |
Format: | AT [cmds] !X5=n [cmds] |
Default: | 0 |
Range: | 0 - 255 |
Unit: | N/A |
Description: | Sets the number of incoming logical channels for X.25. |
X.25 D-CHANNEL - CHANNELS, OUTGOING | |
Type: | Configuration |
Format: | AT [cmds] !X7=n [cmds] |
Default: | 0 |
Range: | 0 - 255 |
Unit: | N/A |
Description: | Sets the number of outgoiing logical channels for X.25. |
X.25 D-CHANNEL - CHANNELS, VIRTUAL | |
Type: | Configuration |
Format: | AT [cmds] !X4=n [cmds] |
Default: | 0 |
Range: | 0 - 255 |
Unit: | N/A |
Description: | Sets the number of permanent virtual channels for X.25. |
X.25 D-CHANNEL - MODULUS | |
Type: | Configuration |
Format: | AT [cmds] !X8=n [cmds] |
Default: | 8 |
Range: | 8, 128 |
Unit: | N/A |
Description: | Sets the sequence modulus for X.25. |
X.25 D-CHANNEL - NEGOTIATION | ||
Type: | Configuration | |
Format: | AT [cmds] !D1=n [cmds] | |
Description: | Selects X.25 parameter negotiation. | |
Command | Function | |
!D1=0 | X.25 negotiation disabled. | |
í !D1=1 | X.25 negotiation enabled. | |
X.25 D-CHANNEL - RECEIVE PACKET SIZE | ||
Type: | Configuration | |
Format: | AT [cmds] !X2=n [cmds] | |
Description: | Sets the size of the received packets for X.25. | |
Command | Function | |
í !X2=7 | Packet size set to 128 bytes. | |
!X2=8 | Packet size set to 256 bytes. | |
X.25 D-CHANNEL - RECEIVE WINDOW SIZE | |
Type: | Configuration |
Format: | AT [cmds] !X0=n [cmds] |
Default: | 2 |
Range: | 1 - 7 |
Unit: | N/A |
Description: | Sets the size of the X.25 receive window. |
X.25 D-CHANNEL - TRANSMIT PACKET SIZE | ||
Type: | Configuration | |
Format: | AT [cmds] !X3=n [cmds] | |
Description: | Sets the size of the transmitted packets for X.25. | |
Command | Function | |
í !X3=7 | Packet size set to 128 bytes. | |
!X3=8 | Packet size set to 256 bytes. | |
X.25 D-CHANNEL - TRANSMIT WINDOW SIZE | |
Type: | Configuration |
Format: | AT [cmds] !X1=n [cmds] |
Default: | 2 |
Range: | 1 - 7 |
Unit: | N/A |
Description: | Sets the size of the X.25 transmit window. |
X.25 LOGICAL CHANNEL | |
Type: | Configuration |
Format: | AT [cmds] %B6=n [cmds] |
Default: | 1 |
Range: | 0 - 255 |
Unit: | N/A |
Description: | Selects the logical channel for X.25 operation. |
X.25 OUTGOING CALL ADDRESS | |
Type: | Configuration |
Format: | AT [cmds] %B17=nnnn [cmds] |
Description: | Sets the address for an outgoing X.25 virtual call. |
X.25 PACKET CALL TIMER | |
Type: | Configuration |
Format: | AT [cmds] %B98=n [cmds] |
Default: | 200 |
Range: | 0 - 600 |
Unit: | Unidentified |
Description: | Sets the packet call timer for X.25 operation. |
X.25 PAD ANCILLARY DEVICE | ||
Type: | Configuration | |
Format: | AT [cmds] %L5=n [cmds] | |
Description: | Selects control of an ancillary device by the PAD. | |
Command | Function | |
%L5=0 | Device disabled. | |
í %L5=1 | Device enabled for data transfer only. | |
%L5=2 | Device enabled for data transfer and command control. | |
X.25 PAD BREAK RESPONSE | |||
Type: | Configuration | ||
Format: | AT [cmds] %L7=n [cmds] | ||
Default: | 0 | ||
Range: | 0 - 31 | ||
Description: | Sets action the PAD takes in response to receiving a BREAK from the DTE. | ||
Bit | Value | Function | |
0 | í 01 | PAD will not send an interrupt packet. PAD will send an interrupt packet. | |
1 | í 01 | PAD will not send a reset packet. PAD will send a reset packet. | |
2 | í 01 | PAD will not send an indication of the break. PAD will send an indication of the break. | |
3 | í 01 | PAD will not escape from the data state. PAD will escape from the data state. | |
4 | í 01 | PAD will not set %L8 to 1. PAD will set %L8 to 1. | |
X.25 PAD CARRIAGE RETURN TRANSLATION | |||
Type: | Configuration | ||
Format: | AT [cmds] %L13=n [cmds] | ||
Default: | 5 | ||
Range: | 0 - 7 | ||
Description: | Selects when the PAD will add line feeds to carriage returns. | ||
Bit | Value | Function | |
0 | 0 í 1 | PAD will not add a line feed after a carriage return being sent to the DTE. PAD will add a line feed after a carriage return being sent to the DTE. | |
1 | í 01 | PAD will not add a line feed after a carriage return being received from the DTE. PAD will add a line feed after a carriage return being received from the DTE. | |
2 | 0 í 1 | PAD will not add a line feed after a carriage return being echoed. PAD will add a line feed after a carriage return being echoed. | |
X.25 PAD - CARRIAGE RETURN PADDING | |
Type: | Configuration |
Format: | AT [cmds] %L9=n [cmds] |
Default: | 0 |
Range: | 0 - 255 |
Unit: | Unidentified |
Description: | Sets the amount of padding after a carriage return. |
X.25 PAD DATA EDITING | ||
Type: | Configuration | |
Format: | AT [cmds] %L15=n [cmds] | |
Description: | Selects whether editing the data being transferred is allowed. | |
Command | Function | |
%L12=0 | Editing disabled. | |
í %L12=1 | Editing enabled. | |
X.25 PAD DELETE CHARACTER | |
Type: | Configuration |
Format: | AT [cmds] %L16=n [cmds] |
Default: | 8 |
Range: | 0 - 127 |
Unit: | 1 ASCII character |
Description: | Sets the character used for character deletion. |
X.25 PAD - DISCARD DATA | ||
Type: | Configuration | |
Format: | AT [cmds] %L8=n [cmds] | |
Description: | Selects whether the PAD will deliver data to the DTE. | |
Command | Function | |
í %L8=0 | Deliver data to the DTE. | |
%L8=1 | Discard data. | |
X.25 PAD ECHO | ||
Type: | Configuration | |
Format: | AT [cmds] %L2=n [cmds] | |
Description: | Selects whether PAD functions will echo incoming characters. | |
Command | Function | |
%L2=0 | PAD echo disabled. | |
í %L2=1 | PAD echo enabled. | |
X.25 PAD ECHO MASK | |||
Type: | Configuration | ||
Format: | AT [cmds] %L20=n [cmds] | ||
Default: | 248 | ||
Range: | 0 - 255 | ||
Description: | Selects which control characters will be echoed. | ||
Bit | Value | Function | |
0 | í 01 | Carriage return will be echoed. Carriage return will not be echoed. | |
1 | í 01 | Line feed will be echoed. Line feed will not be echoed. | |
2 | í 01 | The control characters VT, HT, and form feeds will be echoed. The control characters VT, HT, and form feeds will not be echoed. | |
3 | 0 í 1 | Bells and backspaces will be echoed. Bells and backspaces will not be echoed. | |
4 | 0 í 1 | The control character ENQ and escapes will be echoed. The control character ENQ and escapes will not be echoed. | |
5 | 0 í 1 | The control characters ACK, NAK, STX, SOH, EOT, ETB, and ETX will be echoed. The control characters ACK, NAK, STX, SOH, EOT, ETB, and ETX will not be echoed. | |
6 | 0 í 1 | Parameters 16, 17, and 18 will be echoed. Parameters 16, 17, and 18 will not be echoed. | |
7 | 0 í 1 | All other control characters will be echoed. All other control characters will not be echoed. | |
X.25 PAD FLOW CONTROL | ||
Type: | Configuration | |
Format: | AT [cmds] %L12=n [cmds] | |
Description: | Selects flow control for the X.25 PAD. | |
Command | Function | |
%L12=0 | Flow control disabled. | |
í %L12=1 | Flow control enabled. | |
X.25 PAD - FORM FEED PADDING | |
Type: | Configuration |
Format: | AT [cmds] %L22=n [cmds] |
Default: | 0 |
Range: | 0 - 255 |
Unit: | Unidentified |
Description: | Sets the amount of padding after a form feed. |
X.25 PAD FORWARDING | |||
Type: | Configuration | ||
Format: | AT [cmds] %L3=n [cmds] | ||
Default: | 2 | ||
Range: | 0 - 127 | ||
Description: | Selects which characters will be forwarded through the PAD. | ||
Bit | Value | Function | |
0 | í 01 | Alphanumeric characters will not be forwarded. Alphanumeric characters (A-Z, a-z, 0-9) will be forwarded. | |
1 | 0 í 1 | Carriage returns will not be forwarded. Carriage returns will be forwarded. | |
2 | í 01 | The control characters ENQ, ACK, bells, and escapes will not be forwarded. The control characters ENQ, ACK, bells, and escapes will be forwarded. | |
3 | í 01 | The control characters CAN, DC2, and delete will not be forwarded. The control characters CAN, DC2, and delete will be forwarded. | |
4 | í 01 | The control characters ETX and EOT will not be forwarded. The control characters ETX and EOT will be forwarded. | |
5 | í 01 | The control characters HT, LT, VT, and form feeds will not be forwarded. The control characters HT, LT, VT, and FF will be forwarded. | |
6 | í 01 | All other control characters will not be forwarded. All other control characters will be forwarded. | |
X.25 PAD IDLE TIME | |
Type: | Configuration |
Format: | AT [cmds] %L4=n [cmds] |
Default: | 0 |
Range: | 0 - 255 |
Unit: | Unidentified |
Description: | Sets the PAD’s idle time delay. |
X.25 PAD LINE DELETE CHARACTER | |
Type: | Configuration |
Format: | AT [cmds] %L17=n [cmds] |
Default: | 24 |
Range: | 0 - 127 |
Unit: | 1 ASCII character |
Description: | Sets the character used for line deletion. |
X.25 PAD LINE DISPLAY CHARACTER | |
Type: | Configuration |
Format: | AT [cmds] %L18=n [cmds] |
Default: | 18 |
Range: | 0 - 127 |
Unit: | 1 ASCII character |
Description: | Sets the character used for line display. |
X.25 PAD - LINE FEED PADDING | |
Type: | Configuration |
Format: | AT [cmds] %L14=n [cmds] |
Default: | 0 |
Range: | 0 - 255 |
Unit: | Unidentified |
Description: | Sets the amount of padding after a line feed. |
X.25 PAD - LINE WRAP | |
Type: | Configuration |
Format: | AT [cmds] %L10=n [cmds] |
Default: | 0 |
Range: | 0 - 255 |
Unit: | 1 character |
Description: | Sets the length of a line for the X.25 PAD. |
X.25 PAD - LOCAL SERIAL PORT SPEED | ||
Type: | Configuration | |
Format: | AT [cmds] %L11=n [cmds] | |
Description: | Sets the speed of operation for the serial port when using the X.25 PAD. | |
Command | Function | |
%L11=2 | Set serial port speed to 300bps. | |
%L11=3 | Set serial port speed to 1200bps. | |
%L11=4 | Set serial port speed to 600bps. | |
%L11=12 | Set serial port speed to 2400bps. | |
%L11=13 | Set serial port speed to 4800bps. | |
%L11=14 | Set serial port speed to 9600bps. | |
%L11=15 | Set serial port speed to 19.2Kbps. | |
í %L11=16 | Set serial port speed to 38.4Kbps. | |
X.25 PAD PARITY | ||
Type: | Configuration | |
Format: | AT [cmds] %L21=n [cmds] | |
Description: | Selects the format of the parity bit. | |
Command | Function | |
%L21=0 | No parity. | |
%L21=3 | Use setting in @P3. | |
X.25 PAD RECALL | |
Type: | Configuration |
Format: | AT [cmds] %L1=n [cmds] |
Default: | 0 |
Range: | 0, 1, 32 - 126 |
Unit: | 1 ASCII character (see below for exceptions) |
Description: | Sets the character for PAD recall. 0 disables recall, and 1 sets it to the DLE control character. |
X.25 PAD SERVICE SIGNALS | ||
Type: | Configuration | |
Format: | AT [cmds] %L6=n [cmds] | |
Description: | Selects which PAD service signals will be sent to the user. | |
Command | Function | |
%L6=0 | No signals will be sent. | |
%L6=1 | All signals except prompt will be sent. | |
%L6=4 | Only prompt will be sent. | |
%L6=5 | All signals will be sent. | |
X.25 PAD SERVICE SIGNAL DESTINATION | ||
Type: | Configuration | |
Format: | AT [cmds] %L19=n [cmds] | |
Description: | Selects where PAD service signals will be sent. | |
Command | Function | |
%L19=0 | Signals will not be sent. | |
%L19=1 | Signals will be sent to the printer. | |
í %L19=2 | Signals will be sent to the monitor. | |
X.25 PVC | ||
Type: | Configuration | |
Format: | AT [cmds] %B5=n [cmds] | |
Description: | Selects whether X.25 will use Permanent Virtual Channel. | |
Command | Function | |
í %B5=0 | X.25 PVC disabled. | |
%B5=1 | X.25 PVC enabled. | |
X.25 RECEIVE PACKET SIZE | |
Type: | Configuration |
Format: | AT [cmds] %B2=n [cmds] |
Default: | 0 |
Range: | 0, 7 - 10 |
Unit: | N/A |
Description: | Sets the size of the received packets for X.25. |
X.25 RECEIVE THROUGHPUT | ||
Type: | Configuration | |
Format: | AT [cmds] %B11=n [cmds] | |
Description: | Sets the throughput for receiving X.25. | |
Command | Function | |
í %B11=0 | Use network speed. | |
%B11=3 | Throughput set to 75bps. | |
%B11=4 | Throughput set to 110bps. | |
%B11=5 | Throughput set to 300bps. | |
%B11=6 | Throughput set to 600bps. | |
%B11=7 | Throughput set to 1200bps. | |
%B11=8 | Throughput set to 2400bps. | |
%B11=9 | Throughput set to 4800bps. | |
%B11=10 | Throughput set to 9600bps. | |
%B11=11 | Throughput set to 19.2Kbps. | |
%B11=12 | Throughput set to 48Kbps. | |
%B11=13 | Throughput set to 64Kbps. | |
X.25 RECEIVE WINDOW SIZE | |
Type: | Configuration |
Format: | AT [cmds] %B0=n [cmds] |
Default: | 0 |
Range: | 0 - 8 |
Unit: | N/A |
Description: | Sets the size of the X.25 receive window. |
X.25 RESET CODE | ||
Type: | Read-only | |
Format: | AT [cmds] %B20? [cmds] | |
Description: | Reports the reason for an X.25 reset. | |
Value | Meaning | |
0 | Normal operation - no reset has occurred. | |
1 | DTE caused reset. | |
2 | Local procedure error occurred. | |
3 | Destination address is incompatible. | |
4 | Network is busy. | |
5 | Remote procedure error occurred. | |
6 | Cause of reset unknown. | |
X.25 RESET TIMER | |
Type: | Configuration |
Format: | AT [cmds] %B99=n [cmds] |
Default: | 180 |
Range: | 0 - 600 |
Unit: | Unidentified |
Description: | Sets the reset timer for X.25 operation. |
X.25 RPOA | |
Type: | Configuration |
Format: | AT [cmds] %B14=xxxx [cmds] |
Description: | Sets the RPOA for X.25. |
X.25 TRANSMIT DELAY TIME | |
Type: | Configuration |
Format: | AT [cmds] %B19=n [cmds] |
Default: | 0 |
Range: | 0 - 65535 |
Unit: | 1ms |
Description: | Sets the delay time for X.25 transmission. |
X.25 TRANSMIT PACKET SIZE | |
Type: | Configuration |
Format: | AT [cmds] %B3=n [cmds] |
Default: | 0 |
Range: | 0, 7 - 10 |
Unit: | N/A |
Description: | Sets the size of the transmitted packets for X.25. |
X.25 TRANSMIT THROUGHPUT | ||
Type: | Configuration | |
Format: | AT [cmds] %B12=n [cmds] | |
Description: | Sets the throughput for transmitting X.25. | |
Command | Function | |
í %B12=0 | Use network speed. | |
%B12=3 | Throughput set to 75bps. | |
%B12=4 | Throughput set to 110bps. | |
%B12=5 | Throughput set to 300bps. | |
%B12=6 | Throughput set to 600bps. | |
%B12=7 | Throughput set to 1200bps. | |
%B12=8 | Throughput set to 2400bps. | |
%B12=9 | Throughput set to 4800bps. | |
%B12=10 | Throughput set to 9600bps. | |
%B12=11 | Throughput set to 19.2Kbps. | |
%B12=12 | Throughput set to 48Kbps. | |
%B12=13 | Throughput set to 64Kbps. | |
X.25 TRANSMIT WINDOW SIZE | |
Type: | Configuration |
Format: | AT [cmds] %B1=n [cmds] |
Default: | 0 |
Range: | 0 - 8 |
Unit: | N/A |
Description: | Sets the size of the X.25 transmit window. |
X.25 USER DATA | |
Type: | Configuration |
Format: | AT [cmds] %B18=xxxx [cmds] |
Description: | Sets miscellaneous user data for X.25. |
X.25 USER ID | |
Type: | Configuration |
Format: | AT [cmds] %B13=xxxx [cmds] |
Description: | Sets the network user ID for X.25. |
XON/XOFF PASS THROUGH | ||
Type: | Configuration | |
Format: | AT [cmds] \Xn [cmds] | |
Description: | Selects whether XON and XOFF characters will be sent to the remote modem. | |
Command | Function | |
í \X0 | XON/XOFF characters trapped. | |
\X1 | XON/XOFF characters sent to remote modem. | |