MAXTECH CORPORATION
MAXTECH 9424H
Card Type | Modem(asynchronous) |
Chip Set | Unidentified |
Maximum Data Rate | 2400bps |
Maximum Fax Rate | 9600bps |
Data Bus | 8 bit ISA |
Fax Class | Class I |
Data Modulation Protocol | Bell 103A/212A ITU-T V.21, V.22, V.22bis |
Fax Modulation Protocol | ITU-T V.21CH2, V.27ter, V.29 |
Error Correction/Compression | MNP5, V.42, V.42bis |

CONNECTIONS | ||||||
Function | Label | Function | Label | |||
Line in | CN1 | Line out | CN2 | |||
SERIAL PORT ADDRESS | ||
Setting | J1 | J2 |
COM1 (3F8h) | Pins 1 & 2 closed | Pins 1 & 2 closed |
COM2 (2F8h) | Pins 2 &3 closed | Pins 1 & 2 closed |
COM3 (3E8h) | Pins 1 & 2 closed | Pins 2 &3 closed |
COM4 (2E8h) | Pins 2 &3 closed | Pins 2 &3 closed |
INTERRUPT | ||||
Setting | J3 | J4 | J5 | J6 |
2 | On | Off | Off | Off |
3 | Off | On | Off | Off |
4 | Off | Off | On | Off |
5 | Off | Off | Off | On |
Proprietary AT Command Set
BIT-MAPPED REGISTER S14 | ||
Format | AT [cmds] S14=n [cmds] | |
Default: | 170 | |
Range: | 0 - 174 | |
Unit: | Bit-mapped | |
Description: | Controls command echo, result codes, dialing mode, and answer/originate mode | |
Bit | Value | Function |
0 | 0 | Not used |
1 | 0 í 1 | Command echo off Command echo on |
2 | í 01 | Result codes enabled Result codes disabled |
3 | 0 í 1 | Numeric result codes Verbose result codes |
4 | 0 | Not used |
5 | 0 í 1 | Tone dialing selected Pulse dialing selected |
6 | 0 | Not used |
7 | 0 í 1 | Answer mode selected Originate mode selected |
BIT-MAPPED REGISTER S21 | ||
Format | AT [cmds] S21=n [cmds] | |
Default: | 0 | |
Range: | 0 - 249 | |
Unit: | Bit-mapped | |
Description: | Selects jack type, low DTR action, DCD signal, DSR signal, and the Long Space Disconnect function | |
Bit | Value | Function |
0 | í 01 | Selects RJ-11jack Selects RJ-12 or RJ-13 jack |
1 | 0 | Not used |
2 | 0 | Not used |
4, 3 | í 0001 10 11 | DTR signal ignored Modem goes to command mode on low DTR Modem disconnects on low DTR Modem is initialized on low DTR |
5 | í 01 | DCD forced high DCD normal |
6 | í 01 | DSR forced high DSR normal |
7 | í 01 | Long Space Disconnect function disabled Long Space Disconnect function enabled |
BIT-MAPPED REGISTER S22 | ||
Format | AT [cmds] S22=n [cmds] | |
Default: | 118 | |
Range: | 0 - 255 | |
Unit: | Bit-mapped | |
Description: | Controls volume and speaker settings, result codes, and make/break pulse ratio | |
Bit | Value | Function |
1, 0 | 00 í 0110 11 | Not used Low volume setting Medium volume setting Highest volume setting |
3, 2 | 00 í 0110 11 | Speaker disabled Speaker enabled until carrier signal detected Speaker enabled Speaker off during dialing |
6, 5 ,4 | 000 001 010 011 100 101 110 í 111 | Busy and dialtone detection disabled, result codes 0-4 enabled Not used Not used Not used Busy and dialtone detection disabled, result codes 0-5, 10 enabled Busy tone detection disabled, dialtone detection enabled, result codes 0-6, 10 enabled Busy tone detection enabled, dialtone detection disabled, result codes 0-5, 7, 10 enabled Busy and dialtone detection enabled, all result codes enabled |
7 | í 01 | 39/61ms at 10pps (North America) 33/67ms at 10pps (Europe) |
BIT-MAPPED REGISTER S23 | ||
Format | AT [cmds] S23=n [cmds] | |
Default: | 7 | |
Range: | 0-247 | |
Unit: | Bit-mapped | |
Description: | Grants/denies remote digital loopback, connect speed, parity and guard tone | |
Bit | Value | Function |
0 | 0 í 1 | Remote digital loopback denied Remote digital loopback allowed |
2, 1 | 00 01 10 í 11 | Connect at 0-300bps Not used Connect at 1200bps Connect at 2400bps |
3 | 0 | Not used |
5,4 | í 0001 10 11 | Parity even Space parity Parity odd No Parity |
7, 6 | í 0001 10 11 | Guard tone disabled Guard tone 550Hz enabled Guard tone 1800Hz enabled Not used |
BIT-MAPPED REGISTER S27 | |||||
Format: | AT [cmds] S27=n [cmds] | ||||
Default: | 64 | ||||
Range: | 0-127 | ||||
Description: | Asynchronous operation, leased/switched line, ITU-U/Bell operation | ||||
Bit | Value | Function | |||
3, 1, 0 | í 0x00 | Asynchronous operation | |||
2 | í 01 | Switched line Leased line | |||
4 | 0 | Not used | |||
5 | 0 | Not used | |||
6 | 0 í 1 | V.21/V.22 Bell 212A | |||
TEST STATUS | ||
Format | AT [cmds] S16=n [cmds] | |
Default: | 0 | |
Range: | 0 - 122 | |
Unit: | Bit-mapped | |
Description: | Contains status of loopback tests | |
Bit | Value | Function |
0 | í 01 | Local analog loopback test disabled Local analog loopback test enabled |
1 | 0 | Not used |
2 | í 01 | Local digital loopback test disabled Local digital loopback test enabled |
3 | í 01 | Remote digital loopback test disabled Remote digital loopback test enabled |
4 | í 01 | Remote digital loopback test not in progress Remote digital loopback test in progress |
5 | í 01 | Remote digital loopback test with test and error disabled Remote digital loopback test with test and error enabled |
6 | í 01 | Local digital loopback test with self test disabled Local digital loopback test with self test enabled |