DIGITAL LINK CORPORATION
T1 DSU/CSU DL080
Card Type | T1 DSU/CSU |
Chip Set | Unidentified |
I/O Options | AC power connector, DC power connector, serial port, data port via V.35 connector, network interface via 15-pin connector, injection jack, monitor jack |
T1 Transfer Rate | 1.536Mbps |
T1 Protocol | AMI, B8ZS |
Frame type | D4, ESF |
Data Bus | External |
CONNECTIONS | |||
Function | Label | Function | Label |
AC power connector | CN1 | Network port via 15-pin connector | CN5 |
DC power connector | CN2 | Injection jack - send | CN6 |
Data port via V.35 connector | CN3 | Monitor jack - receive | CN7 |
Serial port | CN4 | Fuse | F1 |
USER CONFIGURABLE SETTINGS | |||
Setting | Label | Position | |
» | Contiguous bandwidth allocation | S1/6 | Off |
Alternate bandwidth allocation | S1/6 | On | |
» | DTE clock set at +SCT | S1/7 | Off |
DTE clock set at SCTE | S1/7 | On | |
» | ESF network framing enabled | S2/1 | Off |
D4 network framing enabled | S2/1 | On | |
» | B8ZS line code enabled | S2/2 | Off |
AMI line code enabled | S2/2 | On | |
» | Internal timing source enabled | S2/5 | Off |
Network timing source enabled | S2/5 | On | |
» | Word length 8-bit enabled | S2/11 | Off |
Word length 7-bit enabled | S2/11 | On | |
» | DIP switch configuration enabled | S2/12 | Off |
Terminal configuration enabled | S2/12 | On |
DATA RATE TIME SLOTS | ||||||
Setting | S1/1 | S1/2 | S1/3 | S1/4 | S1/5 | |
1 time slot | Off | Off | Off | Off | On | |
2 time slots | Off | Off | Off | On | Off | |
3 time slots | Off | Off | Off | On | On | |
4 time slots | Off | Off | On | Off | Off | |
5 time slots | Off | Off | On | Off | On | |
6 time slots | Off | Off | On | On | Off | |
7 time slots | Off | Off | On | On | On | |
8 time slots | Off | On | Off | Off | Off | |
9 time slots | Off | On | Off | Off | On | |
10 time slots | Off | On | Off | On | Off | |
11 time slots | Off | On | Off | On | On | |
12 time slots | Off | On | On | Off | Off | |
13 time slots | Off | On | On | Off | On | |
14 time slots | Off | On | On | On | Off | |
15 time slots | Off | On | On | On | On | |
16 time slots | On | Off | Off | Off | Off | |
17 time slots | On | Off | Off | Off | On | |
18 time slots | On | Off | Off | On | Off | |
19 time slots | On | Off | Off | On | On | |
20 time slots | On | Off | On | Off | Off | |
21 time slots | On | Off | On | Off | On | |
22 time slots | On | Off | On | On | Off | |
23 time slots | On | Off | On | On | On | |
» | 24 time slots | Off | Off | Off | Off | Off |
DATA ENCODING | |||
Setting | S1/8 | S1/9 | |
» | Normal encoding | Off | Off |
HDLC encoding | Off | On | |
Forced encoding | On | Off |
LINE BUILD | |||
Net build | S2/3 | S2/4 | |
» | 0dB | Off | Off |
-7.5dB | Off | On | |
-15dB | On | Off |
SERIAL PORT RATE SELECTION | ||||
Setting | S2/6 | S2/7 | S2/8 | |
1200bps | Off | On | On | |
2400bps | Off | On | Off | |
4800bps | Off | Off | On | |
» | 9600bps | Off | Off | Off |
19.2Kbps | On | On | Off |
SERIAL PORT PARITY SELECTION | |||
Setting | SW2/9 | SW2/10 | |
» | None | Off | Off |
Odd | Off | On | |
Even | On | Off |
DIAGNOSTIC LED(S) | |||
LED | Color | Status | Condition |
PWR | Green | On | DSU/CSU power is on and has passed the self test |
PWR | Red | On | DSU/CSU power is on; self test failed. |
PWR | Yellow | Blinking | DSU/CSU power is on; self test is running |
PWR | Yellow | On | DSU/CSU is on; test other than self test is running |
PWR | None | Off | Power is off |
NET | Green | On | Network connection is good |
NET | Red | On | DSU/CSU cannot synchronize to network frame |
NET | Red/Green | Blinking | DSU/CSU is detecting a BPV, OOF, or CRC error signal from network |
NET | Yellow | On | Yellow or blue alarm condition detected on network |
NET | None | Off | Network connection is broken |
NLBK | Yellow | On | DSU or CSU loopback initiated by user or management station |
NLBK | Yellow | Off | DSU or CSU loopback test not running |
ACK | Yellow | On | Remote loop (up or down) detected - Press buttons to run (up) or (down) remote loop test |
ACK | Yellow | Off | DSU/CSU remote loop test not running |
DTE | Yellow | On | DTE loopback running: Press button to run test |
DTE | Yellow | Blinking | DTE loopback running |
DTE | Yellow | Off | DTE loopback not running |
TD | Green | On | DSU/CSU is detecting pulses from the DTE |
TD | Green | Off | DSU/CSU is not detecting pulses from DTE |
RD | Green | On | DSU/CSU is receiving pulses from network |
RD | Green | Off | DSU/CSU is not receiving pulses from network |
RTS | Yellow | On | RTS signal is high |
RTS | Yellow | Off | RTS signal is low |
CTS | Yellow | On | CTS signal is high |
CTS | Yellow | Off | CTS signal is low |
DTR | Yellow | On | DTR signal is high |
DTR | Yellow | Off | DTR signal is low |