BANKSIA TECHNOLOGY PTY, LTD.
PRO 34
Card Type | Fax, Modem (synchronous/asynchronous) |
Chip Set | Unidentified |
Maximum Data Rate | 28.8Kbps |
Maximum Fax Rate | 14.4Kbps |
Data Bus | External |
Fax Class | Class I & II |
Data Modulation Protocol | Bell 103/212A ITU-T V.21, V.22, V.22bis, V.23, V.32, V.32bis, V.34 |
Fax Modulation Protocol | ITU-T V.17, V.27ter, V.29 |
Error Correction/Compression | MNP5, MNP10, V.42, V.42bis |

CONNECTIONS | ||||||
Function | Label | Function | Label | |||
Auxiliary port | CN1 | DC power | CN4 | |||
Line out | CN2 | Power switch | SW1 | |||
RS-232/422 | CN3 | |||||
USER CONFIGURABLE SETTINGS | ||
Setting | Label | Position |
í DTR signal ignored | SW1/1 | On |
DTR signal normal | SW1/1 | Off |
í DCD and DSR forced high | SW1/2 | On |
DCD and DSR normal | SW1/2 | Off |
í Echo disabled | SW1/3 | On |
Echo enabled | SW1/3 | Off |
í Result codes disabled | SW1/4 | On |
Result codes enabled | SW1/4 | Off |
í Leased-line operation | SW1/5 | On |
Switched line operation | SW1/5 | Off |
í Auto-answer enabled on 2nd ring | SW1/6 | On |
Auto-answer disabled on 2 nd ring | SW1/6 | Off |
í Synchronous mode 2 enabled | SW1/7 | On |
Synchronous mode 2 disabled | SW1/7 | Off |
í Dumb mode | SW1/8 | On |
Smart mode | SW1/8 | Off |
í Flow control to XON/XOFF enabled | SW2/1 | On |
Flow control to XON/XOFF disabled | SW2/1 | Off |
í V.25bis command set synchronous HDLC (NRZI) enabled | SW2/2 | On |
V.25bis command set synchronous HDLC (NRZI) disabled | SW2/2 | Off |
í Factory configured - DO NOT ALTER | SW2/5 | Unidentified |
í Factory configured - DO NOT ALTER | SW2/6 | Unidentified |
í Factory configured - DO NOT ALTER | SW2/7 | Unidentified |
í Factory defaults loaded up on power-up | SW2/8 | On |
Do not force factory defaults on power-up | SW2/8 | Off |
AUXILIARY PORT | ||||
Setting | LK1 | LK2 | LK3 | LK4 |
í PSTN | Pins 2 & 3 closed | Pins 1 & 2 closed | Open | Closed |
Leased-line | Pins 1 & 2 closed | Pins 2 & 3 closed | Open | Open |
AUXILIARY PORT - CONTINUED | |||||
Setting | LK5 | LK6 | LK7 | LK8 | LK9 |
í PSTN | Closed | Closed | Open | Closed | Open |
Leased-line | Closed | Open | Closed | Closed | Closed |
MODULATION SELECTION | ||
Setting | SW2/3 | SW2/4 |
factory/stored setting | Off | Off |
28800 carrier | Off | On |
14400 carrier | On | Off |
2400 carrier | On | On |
SUPPORTED COMMAND SET |
Basic AT Commands |
AT, ‘Comma’ |
A, B, E, H, L, M, N, O, P, Q, S, T, V, W, X, Y, Z |
&C, &D, &G, &L, &R, &S, &V, &W, &X, &Y, &Z |
Extended AT Commands |
\B, \G, \J, \V, \Y, \Z |
Special Commands |
*H, )M |
S Registers |
S0, S1, S2, S3, S4, S5, S6, S7, S8, S9, S10, S11, S12, S14, S16, S18, S25, S26, S36, S37, S38 |
Note: See MHI Help file for full command documentation. |
Proprietary AT Command Set
For a full command summary, see BANKSIA TECHNOLOGY PTY, LTD., PRO 144.