ADC KENTROX
T-SERV II
Card Type | T1 CSU |
Chip Set | Unidentified |
I/O options | Diagnostic ports |
Maximum Transfer Rate | 1.544Mbps |
Data Bus | External |
Data Modulation Protocol | B8ZS |

CONNECTIONS | |||
Function | Label | Function | Label |
T1 line out | CN1 | Test signal to network | CN8 |
Network line out | CN2 | Test signal from equipment | CN9 |
RS-232/422 | CN3 | Monitor signal from equipment | CN10 |
DC power | CN4 | Ground | SC1 |
Test signal to equipment | CN5 | Test switch | SW1 |
Test signal from network | CN6 | Alarm cut-off | SW2 |
Monitor signal from network | CN7 | ||
USER CONFIGURABLE SETTINGS | |||
Setting | Label | Position | |
| » | Test signals not sent through pulse density circuits | SW5/1 | On |
Test signals sent through pulse density circuits | SW5/1 | Off | |
| » | Force sending of digital ON after 15 OFF signals | SW5/2 | Off |
Force sending of digital ON after 47 OFF signals | SW5/2 | On | |
| » | QRSS will not cause low pulse density error | SW5/3 | On |
QRSS will cause low pulse density error three times every two seconds | SW5/3 | Off | |
| » | Pulse density monitor enabled | SW5/4 | Off |
Pulse density monitor disabled | SW5/4 | On | |
| » | Use unframed keep-alive signal | SW5/5 | On |
Use framed keep-alive signal | SW5/5 | Off | |
| » | Factory configured - do not alter | SW5/6 | N/A |
| » | Factory configured - do not alter | SW5/7 | N/A |
| » | Factory configured - do not alter | SW5/8 | N/A |
SIGNAL ATTENUATION | ||
Setting | SW3 | SW4 |
0dBm | On | On |
-7.5dBm | On | Off |
-15dBm | Off | On |
-22.5dBm | Off | Off |
POWER SOURCE | |
Setting | JP1 |
Local power | Up |
Line power | Down |
DIAGNOSTIC LED(S) | |||
LED | Color | Status | Condition |
LOC LP | Yellow | On | CSU is in local loopback test mode |
LOC LP | Yellow | Off | CSU is not in local loopback test mode |
CODE | Yellow | On | CSU received a reset signal |
CODE | Yellow | Off | CSU did not receive a reset signal |
NET LP | Yellow | On | Remote CSU is in loopback test mode |
NET LP | Yellow | Off | Remote CSU is not in loopback test mode |
SEND/FEL | Yellow | On | CSU is transmitting a reset signal |
SEND/FEL | Yellow | Off | CSU is not transmitting a reset signal |
SEND/FEL | Yellow | Blinking | CSU is in remote loopback test mode |
PWR | Green | On | Power is on |
PWR | Green | Off | Power is off |
ACO | Green | On | An alarm has occurred but has been silenced |
ACO | Green | Off | No alarm has occurred or the alarm is active |
KA | Red | On | CSU is sending a keep-alive signal |
KA | Red | Off | CSU is not sending a keep-alive signal |
LOS | Red | On | Signal not detected |
LOS | Red | Off | Signal detected |
AIS | Red | On | CSU is receiving a keep-alive signal |
AIS | Red | Off | CSU is not receiving a keep-alive signal |
BPV | Red | On | CSU has detected bipolar variations |
BPV | Red | Off | CSU has not detected bipolar variations |
BPV | Red | Blinking | CSU has detected bipolar variations |