ADC KENTROX
DATASMART T1 SMDSU MODEL 78963
Card Type | T1 CSU/DSU |
Chipset | Unidentified |
T1 Transfer Rate | 1.544Mbps |
T1 Protocol | B8ZS, ZBTSI |
Frame Type | ESF |
Data Bus | Serial |

CONNECTIONS | |||
Function | Label | Function | Label |
T1 line in | CN1 | V.35 serial data port via DB-25 connector | CN5 |
DCE serial control port | CN2 | AC power in | CN6 |
DTE serial control port | CN3 | Alarm cutoff switch | S5 |
EIA-530 serial data port | CN4 | ||
Note:Standard V.35 serial port is provided on an included adapter cable. | |||
USER CONFIGURABLE SETTINGS | |||
Setting | Label | Position | |
| » | Control port parity disabled | S1/3 | On |
Control port parity enabled | S1/3 | Off | |
| » | Control port parity set to odd | S1/4 | On |
Control port parity set to even | S1/4 | Off | |
| » | Control port uses 8 data bits | S1/5 | On |
Control port uses 7 data bits | S1/5 | Off | |
| » | Control port uses 1 stop bit | S1/6 | On |
Control port uses 2 stop bits | S1/6 | Off | |
| » | V.35 data port enabled | S1/7 | On |
EIA-530 data port enabled | S1/7 | Off | |
| » | Alarm reporting output to DCE control port | S1/8 | On |
Alarm reporting output to DTE control port | S1/8 | Off | |
CONTROL PORT SPEED SELECTION | |||
Setting | S1/1 | S1/2 | |
| » | 9600bps | On | On |
4800bps | On | Off | |
2400bps | Off | On | |
1200bps | Off | Off | |
LINE BUILD OUT SELECTION | |||
Setting | S2 | S3 | |
| » | 0 dB | Off | Off |
-7.5 dB | On | Off | |
-15 dB | Off | On | |
-22.5 dB | On | On | |
THUMBWEEL FUNCTION SELECTION | |||
Function | S4 | S6 | S5 |
Reset loopback tests | Pushed | Position 0 | Not pushed |
Reset to factory defaults and switch settings | Pushed for 2 sec. | Position 3 | Pushed for 2 sec. |
Begin near-end line loopback test | Pushed | Position 4 | Not pushed |
Begin near-end payload loopback test | Pushed | Position 5 | Not pushed |
Begin near-end local loopback test | Pushed | Position 6 | Not pushed |
Begin data near-end terminal loopback test | Pushed | Position 7 | Not pushed |
Reset IDSU address to 00:00:000 | Pushed for 2 sec. | Position 7 | Pushed for 2 sec. |
Send QRST test code | Pushed | Position 8 | Not pushed |
Send 3 in 24 test code | Pushed | Position 9 | Not pushed |
Note:S4 and S6 must always be held for at least one-half of one second for the above functions to take effect. | |||
DIAGNOSTIC LED(S) | |||
LED | Color | Status | Condition |
RCV | Green | On | DSU is receiving data from network |
RCV | Green | Off | DSU is not receiving data from network |
XMT | Green | On | DSU is transmitting data to network |
XMT | Green | Off | DSU is not transmitting data to network |
FEI | Red | On | Remote is out of PLCP lock |
FEI | Red | Blinking | Remote block error detected |
FEI | Red | Off | Remote PLCP normal |
NEI | Red | On | Local DSU is out of PLCP lock |
NEI | Red | Blinking | Local DSU detected a block error |
NEI | Red | Off | Local DSU PLCP normal |
DATA | Green | On | Valid data signal detected |
DATA | Green | Blinking | Network Set, Reset, or Test code detected |
DATA | Green | Off | No valid signal detected |
CV | Red | On | Code Violation, Frame Sync, or CRC error detected |
CV | Red | Off | Error not detected |
LOS | Red | On | Loss Of Signal condition detected |
LOS | Red | Off | Loss Of Signal condition not detected |
OOF | Red | On | Signal is out of frame synchronization |
OOF | Red | Off | Signal is not out of frame synchronization |
AIS | Red | On | Alarm Indication Signal condition detected |
AIS | Red | Off | Alarm Indication Signal condition not detected |
YEL | Yellow | On | Remote Yellow Alarm condition detected |
YEL | Yellow | Blinking | Local Yellow Alarm condition detected |
YEL | Yellow | Off | Yellow Alarm condition not detected |
PWR | Green | On | Power is on |
PWR | Red | On | Self-test failed |
PWR | Green | Blinking | Downloading software |
PWR | N/A | Off | Power is off |
LOOP | Yellow | On | Local loopback test in progress |
LOOP | Yellow | Blinking | Remote loopback test in progress |
LOOP | Yellow | Off | Loopback test not in progress |
SEND | Yellow | On | Test code being sent |
SEND | Yellow | Blinking | Remote loopback test may be in progress but cannot be verified |
SEND | Yellow | Off | Test code not being sent |
ALM | Red | On | Alarm condition detected and awaiting user intervention |
ALM | Green | On | Alarm condition detected; user intervention in progress |
ALM | N/A | Off | Alarm condition not detected |