3COM CORPORATION
3COMIMPACT IQ (3C882)
Card Type | ISDN TA |
Chipset | Unidentified |
Error Correction/Compression | STAC |
ISDN Transfer Rate | 56Kbps x 2/64Kbps x 2 |
ISDN Protocol | V.120, PPP |
Switch Type | 5ESS, DMS100, EWSD, NI-1 |
Data Bus | Serial |

CONNECTIONS | |||
Function | Label | Function | Label |
ISDN U interface | CN1 | Analog adapter 2 | CN4 |
Serial port | CN2 | 9V DC power in | CN5 |
Analog adapter 1 | CN3 | Reset switch | SW1 |
DIAGNOSTIC LED(S) | |||
LED | Color | Status | Condition |
PWR | Green | On | Power is on |
PWR | Green | Off | Power is off |
TEST | Green | On | TA failed last test |
TEST | Green | Blinking | TA is executing test |
TEST | Green | Off | TA is not executing test |
D | Green | On | Signal is not synchronized or ISDN is not connected |
D | Green | Blinking | Signal is synchronized but D-channel protocols not established |
D | Green | Off | Signal is synchronized |
B1 | Green | On | Data call connected on B1 channel |
B1 | Amber | On | Voice call connected on B1 channel |
B1 | Green | Blinking | TA is dialing data call on B1 channel |
B1 | Amber | Blinking | TA is dialing voice call on B1 channel |
B1 | N/A | Off | B1 channel is not connected |
DIAGNOSTIC LED(S) (CON’T) | |||
LED | Color | Status | Condition |
B2 | Green | On | Data call connected on B2 channel |
B2 | Amber | On | Voice call connected on B2 channel |
B2 | Green | Blinking | TA is dialing data call on B2 channel |
B2 | Amber | Blinking | TA is dialing voice call on B2 channel |
B2 | N/A | Off | B2 channel is not connected |
SD | Green | On | TA is transmitting data |
SD | Green | Off | TA is not transmitting data |
RD | Green | On | TA is receiving data |
RD | Green | Off | TA is not receiving data |
TR | Green | On | DTR signal is high |
TR | Green | Off | DTR signal is low |
SUPPORTED STANDARD COMMANDS |
Basic AT Commands |
+++ |
A, E, H, O, Q, V, W, Z |
&C, &D, &F, &W |
Extended AT Commands |
\Q, \T |
S-Registers |
S0 |
Note:See MHI help file for complete information. |
Proprietary AT Command Set
ANALOG ADAPTER CALL ROUTING | |||
Format: | AT [cmds] S63= n [cmds] | ||
Default: | 15 | ||
Range: | 0 - 15 | ||
Description: | Selects which analog adapters may answer which calls. | ||
Bit | Value | Function | |
0 | 0 1 | Calls to analog adapter 1 may not be answered by analog adapter 1. Calls to analog adapter 1 may be answered by analog adapter 1. | |
1 | 0 1 | Calls to analog adapter 1 may not be answered by analog adapter 2. Calls to analog adapter 1 may be answered by analog adapter 2. | |
2 | 0 1 | Calls to analog adapter 2 may not be answered by analog adapter 1. Calls to analog adapter 2 may be answered by analog adapter 1. | |
3 | 0 1 | Calls to analog adapter 2 may not be answered by analog adapter 2. Calls to analog adapter 2 may be answered by analog adapter 2. | |
ANSWER DELAY | ||
Type: | Register | |
Format: | AT [cmds] S75= n [cmds] | |
Description: | Selects whether the TA waits to answer an incoming call. | |
Command | Function | |
| » | S75=0 | TA does not wait to answer an incoming call. |
S75=1 | TA waits two seconds to answer an incoming call. | |
CALL TYPE | ||
Type: | Register | |
Format: | AT [cmds] S61= n [cmds] | |
Description: | Selects whether the TA will force a particular call type. | |
Command | Function | |
| » | S61=0 | D command dials in standard mode and DD command dials in 56Kbps permissive mode. |
S61=1 | Both commands dial in 56Kbps permissive mode. | |
S61=2 | Both commands dial in standard mode. | |
CALLER ID - ANALOG ADAPTER 1 | |
Type: | Register (read-only) |
Format: | AT [cmds] S65? [cmds] |
Description: | Displays the Caller ID information for analog adapter 1. |
CALLER ID - ANALOG ADAPTER 2 | |
Type: | Register (read-only) |
Format: | AT [cmds] S66? [cmds] |
Description: | Displays the Caller ID information for analog adapter 1. |
CALLER ID - ISDN | |
Type: | Register (read-only) |
Format: | AT [cmds] S67? [cmds] |
Description: | Displays the Caller ID information for the ISDN line. |
CHALLENGE HANDSHAKE AUTHENTICATION PROTOCOL | ||
Type: | Register | |
Format: | AT [cmds] S84= n [cmds] | |
Description: | Selects whether the TA will attempt to use CHAP. | |
Command | Function | |
S84=0 | CHAP negotiation enabled. | |
| » | S84=1 | CHAP negotiation disabled. |
COMPRESSION | |
Type: | Configuration |
Format: | AT [cmds] %C n [cmds] |
Description: | Selects whether the TA will use data compression. |
Command | Function |
%C0 | Data compression disabled. |
%C2 | Data compression enabled. |
DIAL - STANDARD | |
Type: | Immediate |
Format: | AT [cmds] D <#> [cmds] |
Description: | Dials the number indicated to make a standard ISDN connection. |
DIAL - PERMISSIVE | |
Type: | Immediate |
Format: | AT [cmds] DD <#> [cmds] |
Description: | Dials the number indicated to make a 56Kbps permissive connection. |
DISPLAY CONFIGURATION AND STATISTICS | |
Type: | Immediate |
Format: | AT [cmds] \S [cmds] |
Description: | Displays the settings of all commands and statistics about the current connection. |
DISPLAY FIRMWARE VERSION | |
Type: | Immediate |
Format: | AT [cmds] %V [cmds] |
Description: | Displays the current firmware version. |
DISPLAY INFORMATION | |
Type: | Immediate |
Format: | AT [cmds] I n [cmds] |
Description: | Displays information requested about the TA. |
Command | Function |
I0 | Displays model number. |
I1 | Displays ROM checksum. |
I2 | Tests and reports ROM checksum. |
I3 | Displays model and version. |
DISPLAY REGISTERS | |
Type: | Immediate |
Format: | AT [cmds] %R n [cmds] |
Description: | Displays the settings of all status registers. |
DISPLAY SERIAL NUMBER | |
Type: | Immediate |
Format: | AT [cmds] %S n [cmds] |
Description: | Displays the serial number of the TA. |
DYNAMIC BANDWIDTH ALLOCATION | ||
Type: | Register | |
Format: | AT [cmds] S70= n [cmds] | |
Description: | Selects whether dynamic bandwidth allocation will be used to allow simultaneous data and voice calls. | |
Command | Function | |
S70=0 | Dynamic bandwidth allocation disabled. | |
| » | S70=1 | Dynamic bandwidth allocation enabled. |
ENDPOINT DISCRIMINATOR | |
Type: | Register |
Format: | AT [cmds] S83= nnnn [cmds] |
Description: | Sets the endpoint discriminator address for multipoint PPP systems. Up to twenty numbers may be specified. |
ENDPOINT DISCRIMINATOR CLASS | ||
Type: | Configuration | |
Format: | AT [cmds] S82= n [cmds] | |
Description: | Sets the endpoint discriminator class for multipoint PPP systems. | |
| Command | Function | |
| S82=1 | User-defined address. | |
| S82=2 | IP address. | |
| S82=3 | 802.1 MAC address. | |
| S82=4 | PPP magic number block. | |
| » | S82=5 | Public Switched Network Directory number. |
LOCAL SERIAL PORT SPEED | ||
Type: | Configuration | |
Format: | AT [cmds] $B n [cmds] | |
Description: | Sets the speed that the TA will communicate with the DTE. | |
Command | Function | |
| » | $B0 | Auto-detects current serial port speed. |
$B1200 | Sets the serial port to 1200bps. | |
$B2400 | Sets the serial port to 2400bps. | |
$B4800 | Sets the serial port to 4800bps. | |
$B9600 | Sets the serial port to 9600bps. | |
$B19200 | Sets the serial port to 19.2Kbps. | |
$B38400 | Sets the serial port to 38.4Kbps. | |
$B57600 | Sets the serial port to 57.6Kbps. | |
$B115200 | Sets the serial port to 115.2Kbps. | |
$B230400 | Sets the serial port to 230.4Kbps. | |
LINE SPEED | ||
Type: | Register | |
Format: | AT [cmds] S60= n [cmds] | |
Description: | Selects the line speed that the TA will attempt to connect at. | |
Command | Function | |
| » | S60=56 | TA will attempt to connect at 56Kbps. |
S60=64 | TA will attempt to connect at 64Kbps. | |
MULTILINK PPP | ||
Type: | Register | |
Format: | AT [cmds] S80= n [cmds] | |
Description: | Selects whether the TA will use Multilink PPP. | |
Command | Function | |
S80=0 | Multilink PPP disabled. | |
| » | S80=1 | Multilink PPP enabled. |
PHONE NUMBER 1 | |
Type: | Register |
Format: | AT [cmds] S51= <#> [cmds] |
Description: | Sets the TA’s first phone number. |
PHONE NUMBER 2 | |
Type: | Register |
Format: | AT [cmds] S53= <#> [cmds] |
Description: | Sets the TA’s first phone number. |
PROTOCOL - B-CHANNEL | ||
Type: | Register | |
Format: | AT [cmds] S71= n [cmds] | |
Description: | Selects the protocol the TA will use on the B channels. | |
Command | Function | |
| » | S71=0 | Auto-select common protocol. |
S71=1 | TA will use PPP conversion. | |
S71=2 | TA will use V.120 | |
SERVICE PROFILE IDENTIFIER 1 | |
Type: | Register |
Format: | AT [cmds] S52= <#> [cmds] |
Description: | Sets the TA’s first SPID. |
SERVICE PROFILE IDENTIFIER 2 | |
Type: | Register |
Format: | AT [cmds] S54= <#> [cmds] |
Description: | Sets the TA’s second SPID. |
SWITCH TYPE | ||
Type: | Register | |
Format: | AT [cmds] S50= n [cmds] | |
Description: | Selects the type of IDSN switch the TA is connected to. | |
Command | Function | |
| » | 0 | Unknown switch type |
1 | AT&T 5ESS custom switch type. | |
3 | NI-1/AT&T 5ESS switch type. | |
6 | NI-1/National Telecom NI-1 or Siemens EWSD switch type. | |
TERMINAL ENDPOINT IDENTIFIER 1 | |
Type: | Register (read-only) |
Format: | AT [cmds] S55? [cmds] |
Description: | Displays the first TEI assigned by the ISDN switch. A value of 255 indicated that the switch did not assign a TEI. |
TERMINAL ENDPOINT IDENTIFIER 1 STATUS | |
Type: | Register (read-only) |
Format: | AT [cmds] S57? [cmds] |
Description: | Returns a value indicating the status of the first TEI. |
Value | Meaning |
0 | TA has not attempted to initialize with SPID 1. |
1 | TA succeeded in initializing with SPID 1. |
2 | TA failed in initializing with SPID 1. |
TERMINAL ENDPOINT IDENTIFIER 2 | |
Type: | Register (read-only) |
Format: | AT [cmds] S56? [cmds] |
Description: | Displays the second TEI assigned by the ISDN switch. A value of 255 indicated that the switch did not assign a TEI. |
TERMINAL ENDPOINT IDENTIFIER 2 STATUS | |
Type: | Register (read-only) |
Format: | AT [cmds] S58? [cmds] |
Description: | Returns a value indicating the status of the second TEI. |
Value | Meaning |
0 | TA has not attempted to initialize with SPID 2. |
1 | TA succeeded in initializing with SPID 2. |
2 | TA failed in initializing with SPID 2. |
U INTERFACE STATUS | |
Type: | Register (read-only) |
Format: | AT [cmds] S59? [cmds] |
Description: | Returns a value indicating the status of the U interface. |
Command | Function |
0 | U interface is not synchronized. |
1 | U interface is synchronized. |
V.120 FRAME TYPE | ||
Type: | Register | |
Format: | AT [cmds] S73= n [cmds] | |
Description: | Selects the frame type that the TA will use when in V.120 mode. | |
Command | Function | |
| » | S73=0 | TA will use I frames. |
S73=1 | TA will use UI frames. | |
V.120 MAXIMUM FRAME SIZE | |
Type: | Register |
Format: | AT [cmds] S74= n [cmds] |
Default: | 256 |
Range: | 240 - 256 |
Unit: | 1 byte |
Description: | Selects the maximum frame size used for V.120 mode. |
Note: Adtran ISDN uses a maximum frame size of 253 bytes. | |