7 4 0 5 A MAXTOR
NO MORE PRODUCED Native| Translation
------+-----+-----+-----
Form 3.5"/SLIMLINE Cylinders 1904| 989| |
Capacity form/unform 405/ MB Heads 4| 16| |
Seek time / track 12.0/ 1.5 ms Sector/track | 50| |
Controller IDE / ATA2 FAST/ENHA Precompensation
Cache/Buffer 256 KB Landing Zone
Data transfer rate 5.000 MB/S int Bytes/Sector 512
11.100 MB/S ext
Recording method RLL 1/7 operating | non-operating
-------------+--------------
Supply voltage 5/12 V Temperature *C 5 55 | -40 70
Power: sleep 0.6 W Humidity % 5 95 | 5 95
standby 0.7 W Altitude km -0.061 3.048|
idle 4.4 W Shock g 10 | 70
seek 5.2 W Rotation RPM 4500
read/write 5.6 W Acoustic dBA 32
spin-up 15.1 W ECC Bit
MTBF h 300000
Warranty Month 24
Lift/Lock/Park YES Certificates
MAXTOR 7546A OEM PRODUCT MANUAL PART #1251 REV. P2
+---------------------------------------------------------+ | +-+-+-+-+ | | +++++++++ | | J25-+ |J23+--J22 XX | J24---+ +-+ XX | +-+J20XX | +-+J19XX | +-+J18XX J1 | +-+J17X* | +-+J16XX | XX | XX | XX | XX1-2 | | 1 | XX Power | XX J2 +---------------------------------------------------------+
MAXTOR 7546A OEM PRODUCT MANUAL PART #1251 REV. P2
Jumper setting
==============
Note: Jumpers J25, J22, J19 and J17 factory reserved.
J16 I/O Channel Ready
----------------------
J16 CLOSED Option Enabled
J16 OPEN Option Disabled (default)
J18 Low Power Spin Mode
------------------------
J18 CLOSED Enabled
J18 OPEN Disabled (default)
J20 Master/Slave
-----------------
J20 CLOSED Only drive in single drive system (Default)
J20 CLOSED Master in dual drive system
J20 OPEN Slave in dual drive system
J23 Write Cache
----------------
J23 OPEN Enabled (default)
J23 CLOSED Disabled
J24 Cable Select
-----------------
J24 OPEN Disabled (default)
J24 CLOSED Enabled