7 2 9 0 A MAXTOR
NO MORE PRODUCED Native| Translation
------+-----+-----+-----
Form 3.5"/SLIMLINE Cylinders | 941| |
Capacity form/unform 290/ MB Heads 4| 14| |
Seek time / track 14.0/ 3.0 ms Sector/track | 43| |
Controller IDE / ATA2 FAST/ENHA Precompensation
Cache/Buffer 64 KB Landing Zone
Data transfer rate 3.000 MB/S int Bytes/Sector 512
9.000 MB/S ext
Recording method RLL 1/7 operating | non-operating
-------------+--------------
Supply voltage 5/12 V Temperature *C 5 55 | -40 71
Power: sleep 1.7 W Humidity % 5 95 | 5 95
standby 1.7 W Altitude km -0.061 3.048|
idle W Shock g 10 | 70
seek 3.8 W Rotation RPM 3551
read/write 4.0 W Acoustic dBA
spin-up W ECC Bit 88
MTBF h 300000
Warranty Month 24
Lift/Lock/Park YES Certificates
MAXTOR 7290A QUICK REFERENCE
+---------------------------------------------------------+ | +-+-+-+-+ | | +++++++++ | | J25-+ |J23+--J22 XX | J24---+ +-+ XX | +-+J20XX | +-+J19XX | +-+J18XX J1 | +-+J17X* | +-+J16XX | XX | XX | XX | XX1-2 | | 1 | XX Power | XX J2 +---------------------------------------------------------+
MAXTOR 7290A QUICK REFERENCE
Jumper setting
==============
Note: Jumper J25 is factory reserved.
Jumper J19 is a spare shunt.
J16 I/O Channel Ready
----------------------
J16 CLOSED Option Enabled
J16 OPEN Option Disabled (default)
J17 ECC
--------
J17 CLOSED 4-Byte emulation
J17 OPEN 11-Byte (default)
J18 Low Power Spin Mode
------------------------
J18 CLOSED Enabled
J18 OPEN Disabled (default)
J20 Master/Slave
-----------------
J20 CLOSED Only drive in single drive system (Default)
J20 CLOSED Master in dual drive system
J20 OPEN Slave in dual drive system
J22 Drive Compatibility
------------------------
J22 CLOSED Enabled
J22 OPEN Disabled (default)
J23 Write Cache
----------------
J23 OPEN Enabled (default)
J23 CLOSED Disabled
J24 Cable Select
-----------------
J24 OPEN Disabled (default)
J24 CLOSED Enabled