M H D - 2 0 2 1 A T H O R N E T 9 FUJITSU
Native| Translation
------+-----+-----+-----
Form 2.5"/SUPERSLIMLINE Cylinders 7289| | |
Capacity form/unform 2160/ MB Heads 3| | |
Seek time / track 13.0/ 2.5 ms Sector/track | | |
Controller IDE / ATA3 ULTRA Precompensation
Cache/Buffer 512 KB Landing Zone
Data transfer rate MB/S int Bytes/Sector 512
33.300 MB/S ext UDM33
Recording method EPR4ML operating | non-operating
-------------+--------------
Supply voltage 5 V Temperature *C 5 55 | -40 65
Power: sleep 0.1 W Humidity % 8 90 | 5 95
standby 0.4 W Altitude km -0.300 3.000| -0.300 12.000
idle 0.9 W Shock g 100 | 500
seek 2.4 W Rotation RPM 4000
read/write W Acoustic dBA 30
spin-up W ECC Bit SMART
MTBF h 300000
Warranty Month
Lift/Lock/Park YES Certificates
FUJITSU MHD-2021/2032AT/MHC2040AT JUMPER SETTING
+-------------------------------------------------------------+
| |
| |
| +-----------------------------------------------C-A-+ |
| | * * * * * * * * * * * * * * * * * * * * * 1 * * | |
| | * * * * * * * * * * * * * * * * * * * * * * * | |
+----+----------------------------------------------SWITCH----+
D B
FUJITSU MHD-2021AT/2032AT/MHC2040AT JUMPER SETTING
Jumper Setting
==============
+-------------------------------------------------------------+
| |
| |
| +---------------------------------------------------+ |
| | * * * * * * * * * * * * * * * * * * * * * 1 * * | |
| | * * * * * * * * * * * * * * * * * * * * * * * | |
+----+----------------------------------------------SWITCH----+
Factory Default
---------------
--------C-A-+
* * * | OPEN
* * * * |
------D-B-+
MASTER-device
* * * |
* * * * |
----------+
Master drive (device #0) or slave (device #1) is
SLAVE-device+ selected.
* * * |
* * xxx | Note:
----------+ Pins A and C should be open.
-CSEL-------+
* xxx |CSEL signal is enabled.
* * * * |
----------+
NOTE
The CSEL setting is not depended on setting between pins B and D.
By connecting the CSEL of the master device to the CSEL Line
(conductor) of the cable and connecting it to ground further, the
CSEL is set to low level.
The device is identified as a master device. At this time, the CSEL
of the slave device does not have a conductor. Thus, since the
slave device is not connected to the CSEL conductor, the CSEL is set
to high level. The device is identified as a slave device.
-ANY DIREC.
Notes on installation
=====================
Installation direction
----------------------
horizontally vertically
+-----------------+ +--+ +--+
| | | +-----+ +-----+ |
| | | | | | | |
+-+-----------------+-+ | | | | | |
+---------------------+ | | | | | |
| | | | | |
| | | | | |
+---------------------+ | +-----+ +-----+ |
+-+-----------------+-+ +--+ +--+
| |
| |
+-----------------+
The drive will operate in all axis (6 directions).