lotus

previous page: Hard Drive: FUJITSU: M2634T 120MB 2.5"/SSL   IDE / AT
  
page up: Hard Drive Specs from FUJITSU
  
next page: Hard Drive: FUJITSU: M2635T 160MB 2.5"/SSL   IDE / AT

Hard Drive: FUJITSU: M2635S 160MB 2.5"/SSL SCSI2 SE




M 2 6 3 5 S    FUJITSU
NO MORE PRODUCED                                      Native|  Translation
                                                      ------+-----+-----+-----
Form                 2.5"/SUPERSLIMLINE    Cylinders    1574|     |     |
Capacity form/unform   160/      MB        Heads           4|     |     |
Seek time   / track  14.5/ 3.0 ms          Sector/track     |     |     |
Controller           SCSI2 SINGLE-ENDED    Precompensation
Cache/Buffer           224 KB READ-AHEAD   Landing Zone
Data transfer rate    2.670 MB/S int       Bytes/Sector      512
                     10.000 MB/S ext SYNC
Recording method     RLL 1/7                        operating  | non-operating
                                                  -------------+--------------
Supply voltage     5 V          Temperature *C         5 55    |    -40 70
Power: sleep              W     Humidity     %         8 90    |      5 95
       standby        0.2 W     Altitude    km    -0.300  3.000| -0.300 12.000
       idle           1.8 W     Shock        g        10       |    100
       seek           2.5 W     Rotation   RPM      4500
       read/write         W     Acoustic   dBA        30
       spin-up            W     ECC        Bit   88-REED SOLOMON,ON THE FLY
                                MTBF         h     150000
                                Warranty Month
Lift/Lock/Park     YES          Certificates                                  

Layout

FUJITSU M2634S/2635S/2636S JUMPER SETTING

  +---------------------------------------------------------+
  |                                                         |XXI
  |                                                         |XXN
  |                                                         |XXT
  |                                                         |XXE
  |                                                         |XXR
  |                                                         |XXF
  |                                                         |XXA
  |                                                         |XXC
  |                                                         |XXE
  |                                                         |XX
  |                                                         |XX
  |                                                         |XX
  |                                                         |XX
  +---------------------------------------------+++++++++---+  1
                                                  ^     ^
                                    NOT USED!!--+++- J1 +- J7
                                                     M     M
                                                     P     P

Jumpers

FUJITSU M2634S/2635S/2636S JUMPER SETTING

Jumper Setting
==============

* = Factory default

 JMP1 SCSI level
 ---------------
   SHORT*   SCSI level : Common Command Set
   OPEN     SCSI level : SCSI-2

 JMP2 Unit Attention
 --------------------
   SHORT*   UNIT ATTENTION enabled
   OPEN     UNIT ATTENTION disabled

 JMP3 SCSI parity
 ----------------
   SHORT*   SCSI parity enabled
   OPEN     SCSI parity disabled

 JMP4
 ----
   SHORT*   Spin up at power on
   OPEN     Spin via START/STOP UNIT command

 SCSI ID JMP7/JMP6/JMP5
 ----------------------
    JMP7    JMP6    JMP5    ID
    ====    ====    ====  ======
    OPEN    OPEN    OPEN    0
    OPEN    OPEN    SHORT   1
    OPEN    SHORT   OPEN    2
    OPEN    SHORT   SHORT   3
    SHORT   OPEN    OPEN    4
    SHORT   OPEN    SHORT   5
    SHORT   SHORT   OPEN    6
    SHORT*  SHORT*  SHORT*  7

NOTE
The drive is shipped from the factory with the SCSI ID set to 7.
This provides the drive with enough shorting straps for any ID. It
must be remembered though that the host adapter normally takes ID 7
with all peripheral devices using IDs 0 through to 6.

Install

FUJISTU M2634S/2635S/2636S JUMPER SETTING

Notes On Installation
=====================

Installation direction
----------------------

     horizontally                           vertically
   +-----------------+             +--+                       +--+
   |                 |             |  +-----+           +-----+  |
   |                 |             |  |     |           |     |  |
 +-+-----------------+-+           |  |     |           |     |  |
 +---------------------+           |  |     |           |     |  |
                                   |  |     |           |     |  |
                                   |  |     |           |     |  |
 +---------------------+           |  +-----+           +-----+  |
 +-+-----------------+-+           +--+                       +--+
   |                 |
   |                 |
   +-----------------+

Installation Direction
----------------------
The drive may be installed in any orientation due to balanced
actuator design.

Mounting screws
---------------
Either side or underside mounting may be used. Standard models
require 4, M3x8 screws.

Cooling
-------
The drive should be kept within it's operating limits.

Mounting in Cabinet
-------------------
Note the following points regarding mounting of the HDD in a cabinet.
If circumstances prevent the HDD from being mounted as explained
below, contact to distributers, reseller, or our sales offices.

- Mount the HDD in the specified orientation.

Mounting the HDD in an orientaion other than the specified one may
adversely affect the temperature or may cause unexpected mechanical
stress to the HDD. This may lead to a failure to guarantee the
reliability level stated in the device specifications.

- Use the specified mounting screw holes.

Mount the HDD using the mounting screw holes for each model.

If the HDD is attached by a means other than screws or with screws
but not at all specified locations (four locations), unexpected
vibration or shock may be applied to the HDD or the HDD may
mechanically resonate. This may lead to a failure to guarantee the
vibration and shock resistance levels stated in the device
specifications.

- Use mounting screws of appropriate length.

A screw shorter than appropriate length is likely to loosen, causing
the HDD to drop off the cabinet.

A screw longer than appropriate length may touch the HDD body,
causing external vibration or shock to the HDD body. This may lead to
a failure to guarantee the vibration and shock resistance levels
stated in the device specifications.

- Ensure clearance between the HDD and the cabinet.

Be sure that there is a minimum 2.5 mm clearance between the HDD and
the cabinet. Failure to do so may block ventilation and adversely
affect the operating temperature of the HDD. It may also cause the
HDD to touch the cabinet, which may then induce electrical noise or
transmit external mechanical vibration or shock directly to the HDD
body. This may result in degraded HDD performance and reliability.

Pay special attention to those models whose DE potential is not zero
volatage. If this type of model contacts the cabinet connecting the
DE to zero volatage, data errors or device faults will occur.

Grounding
---------
In an HDD with a frame, the DE and frame are electrically isolated
from each other.

The DE is connected to signal ground (SG); the frame is connected to
frame ground (FG). Isolating the DE and frame in this way prevents
the adverse effects of external electrical noise.

Generally, a computer system uses some means of connecting SG and FG
at one point in the system. The method used may vary depending on the
system structure or environmental conditions.

The DE potential in some models is not zero volatage. Be careful not
to ground the DE body of this type of model.

SCSI cable connection
---------------------
Do not confuse the connector orientation when connecting the SCSI
cable. Connecting the cable in the wrong orientation may blow the
fuse of the SCSI device that supplies power to the terminating
resistor. If the SCSI device has no fuse, misconnection may destroy
the SCSI cable.

Power-off
---------
When power is turned off, a dynamic brake stops the rotating spindle
motor. This requires a given time until the motor is completely
stopped.

Applying vibration or shock to the HDD while the spindle motor
rotates after power-off may damage the HDD.

Connecting and Disconnecting Interface Connector (2.5-inch HDD)
---------------------------------------------------------------
The printed circuit board assembly of the 2.5-inch HDD is about 0.9
mm thinner than that of conventional HDDs. When connecting or
disconnecting the interface connector, push or pull the connector
straight so as to not give excess stress to the printed circuit board
assembly. Never force a connector. Excess stress may cause the
printed circuit board assembly to warp or crack, resulting in poor
(or no) contact.

Hot Plug (SCSI Device)
----------------------
Our HDDs are designed to support the hot plug feature. However, a
drop in output voltage, output interruption, or noise may be caused
while the HDD is starting. To minimize these symptoms, it is
recommended that a discrete power supply be installed for each HDD.

Also, connection or disconnection of the HDD may cause noise on the
interface signal line and cause an interface malfunction.

To prevent such a failure, connect zero volatage (SG) first, then
connect the interface line, and finally connect the power line.
Reverse the procedure when disconnecting the HDD.

When disconnecting the HDD, do not apply vibration or shock to the
HDD, before the power is turned off. This may disturb control of the
head positioning and degrade data read-write performance.

In the worst case, applying excess shock may damage the head or disk,
resulting in data destruction.

If there is a chance that the power to the HDD containing the
terminating resistor will be turned off, design the system so that
power to the terminating resistor (TERMPWR) is supplied from another
SCSI device. Generally, TERMPWR is supplied from the initiator
(host).

Features

FUJITSU MEDIA DEFECTS

Media Defects
-------------
Before the unit leaves the factory, media defects are listed on the
MEDIA DEFECT LIST. This list is written on the media in the SA space
which is a reserved area of the disk.

General

FUJITSU => GDT

Tips & Hints about ICP controllers and other peripherals
========================================================

Tagged queues and Fujitsu M 26xx harddisks
------------------------------------------
Fujitsu Harddisks of the M26XX series do not support the SCSI-II
feature tagged queues. You should disable this feature in the
initialize disks menue of the GDTSetup program. An inquiry command
shows, that the harddisk supports tagged queues (this is why you can
enable it in the GDTSetup) but this is not true as stated by Fujitsu
Germany.













TOP
previous page: Hard Drive: FUJITSU: M2634T 120MB 2.5"/SSL   IDE / AT
  
page up: Hard Drive Specs from FUJITSU
  
next page: Hard Drive: FUJITSU: M2635T 160MB 2.5"/SSL   IDE / AT