M 1 6 0 6 S A U < 1 1 / 1 9 9 5 FUJITSU
NO MORE PRODUCED Native| Translation
------+-----+-----+-----
Form 3.5"/SLIMLINE Cylinders 3456| | |
Capacity form/unform 1091/ MB Heads 6| | |
Seek time / track 10.0/ 3.0 ms Sector/track | | |
Controller SCSI2 SI/FAST Precompensation
Cache/Buffer 512 KB SEGMENTED Landing Zone
Data transfer rate 5.500 MB/S int Bytes/Sector 512
10.000 MB/S ext SYNC
Recording method RLL 1/7 operating | non-operating
-------------+--------------
Supply voltage 5/12 V Temperature *C 5 55 | -40 60
Power: sleep W Humidity % 8 80 | 5 95
standby W Altitude km -0.300 3.000| -0.300 12.000
idle W Shock g 5 | 50
seek W Rotation RPM 5400
read/write W Acoustic dBA 38
spin-up W ECC Bit
MTBF h 800000
Warranty Month 24
Lift/Lock/Park YES Certificates
FUJITSU M1603S/M1606S JUMPER SETTING A1CA 01310-0011
+---------------------------------------------------------+
| CNH1 +----+ |XX
| 1+-+ | | |XXI
| CN6 | | | | |XXN
| ++++++ +-+8|RP1 | |XXT
| +----+ |TERM| |XXE
| 10 2 | | |XXR
| 9 1 +----+ |XXF
| |XXA
| |XXC
| |XXE
| |XX
| 2 1 |XX
| +-+ CN5 |XX
| +-+ | +5V
| |XX
| |XX
+---------------------------------------------------------+ +12V
Drives manufactured before November 1995!
FUJITSU M1603S/M1606S JUMPER SETTING C1CA 01310-0011
Jumper Setting
==============
x = Factory default setting
CNH1 SCSI ID ------------- +----------+-----------------------+ | SCSI ID | Jumpers | | | 5-6 | 3-4 | 1-2 | +----------+-------+-------+-------+ |x 0 | OPEN | OPEN | OPEN | +----------+-------+-------+-------+ | 1 | OPEN | OPEN | CLOSED| +----------+-------+-------+-------+ | 2 | OPEN | CLOSED| OPEN | +----------+-------+-------+-------+ | 3 | OPEN | CLOSED| CLOSED| +----------+-------+-------+-------+ | 4 | CLOSED| OPEN | OPEN | +----------+-------+-------+-------+ | 5 | CLOSED| OPEN | CLOSED| +----------+-------+-------+-------+ | 6 | CLOSED| CLOSED| OPEN | +----------+-------+-------+-------+ | 7 | CLOSED| CLOSED| CLOSED| +----------+-------+-------+-------+
NOTE
Always ensure that the device ID selected is unique to the SCSI bus.
The controller is often configured at ID 7 so it is the best to
avoid this ID number for the drive.
CNH1 Spindle Motor Control
--------------------------
Pins 7-8 OPEN By Command
xCLOSED Auto
CN6 Remote SCSI ID Connector
----------------------------
+1-3-5-7-9+
|o o o o o| Side View
|o o o o o|
+2-4-6-8-10
+------------+--------+
| PINS | SIGNAL |
+------------+--------+
|Pin 2 |-ID0 |
+------------+--------+
|Pin 4 |-ID1 |
+------------+--------+
|Pin 6 |-ID2 |
+------------+--------+
|Pins 1, 3, 5|GND |
+------------+--------+
|Pins 7 10 |RESERVED|
+------------+--------+
CN5 External operator panel connector
-------------------------------------
Pin 01 LED(V)
Pin 02 -LED
FUJITSU M1603S/M1606S JUMPER SETTING A1CA 01310-0011
Notes On Installation
=====================
Drive mounting
--------------
horizontally vertically
+-----------------+ +--+ +--+ +------------------+
| | | +-----+ +-----+ | | | x
| | | | | | | | x+----------------+x
+-+-----------------+-+ | | | | | | ||x x||
+---------------------+ | | | | | | || x x ||
| | | | | | || x x ||
x x | | | | | | || x x ||
+------x------x-------+ | +-----+ +-----+ | || xx ||
+-+------x--x-------+-+ +--+ +--+ || x x ||
| xx | || x x ||
| x x | || x x ||
+---x--------x----+ |x x|
x x x++----------------++x
UNACCEPTABLE! UNACCEPTABLE!
Orientation
-----------
The drive may be installed in one of three orientations; PCA down
or on either edge. Inclination from vertical or horizontal should
not exceed 5*.
Mounting screw fixing
---------------------
When the mounting screw holes on the side of the drive are used, then
use only the two pairs of outer holes. Do not use the centre hole
in conjunction with only one of the outer holes. The screw must not
penetrate the drive by more than 4.5 millimetres.
Grounding
---------
Sufficient grounding will be provided for correct operation when
the drive is screwed into an electrically grounded frame.
Cooling
-------
Allow space above and below the drive to provide for adequate air
flow. Fan cooling is recommended. The disk enclosure temperature,
measured at top centre, should never exceed 60*C.
Termination
-----------
A terminating resistor should be installed at both ends of the
SCSI bus. When shipped from the factory, this drive is terminated.
If the drive is to be used in the middle of the SCSI cable with
other terminated devices at the ends, or if external termination
is to be used, then the terminating resistor pack on the drive MUST
be removed.
Termination Power
-----------------
Terminator power is supplied internally and to the SCSI BUS via a
fuse.