EMULEX CORPORATION
IB02
Data bus: 8-bit, ISA
Size: Full-length, full-height card
Hard drives supported: Up to seven SCSI devices
Floppy drives supported: None
CONNECTIONS | |
Function | Location |
50-pin SCSI connector-external | J1 |
50-pin SCSI connector-internal | J2 |
USER CONFIGURABLE SETTINGS | |||
Function | Location | Setting | |
» | Not used | SW1/switch 3 | off |
» | Not used | SW1/switch 4 | off |
» | Factory configured - do not alter | SW2/switch 1 | off |
» | DMA Channel 1 selected | SW2/switch 2 | on |
DMA Channel 3 selected | SW2/switch 2 | off | |
» | SCSI parity check enabled | SW2/switch 6 | on |
SCSI parity check disabled | SW2/switch 6 | off | |
» | SCSI bus disconnect enabled | SW2/switch 7 | on |
SCSI bus disconnect disabled | SW2/switch 7 | off | |
» | Factory configured - do not alter | SW3/switch 1 & 2 | off |
» | Factory configured - do not alter | SW3/switch 8 | off |
INTERRUPT REQUEST | ||||
IRQ | SW2/switch 3 | SW2/switch 4 | SW2/switch 5 | |
» | IRQ2 | on | off | on |
IRQ5 | off | on | off |
DMA TRANSFER MODE | ||
Mode | SW1/switch 1 | SW1/switch 2 |
Single-byte (for use with PC, PC/XT) | on | on |
8-byte (for use in a PC/AT with DOS) | on | off |
Reserved | off | on |
4-byte (for use in a PC/AT with multi-tasking) | off | off |
SCSI ADDRESS | |||
SCSI ID | SW2/switch 8 | SW2/switch 9 | SW2/switch 10 |
0 | off | off | off |
1 | on | off | off |
2 | off | on | off |
3 | on | on | off |
4 | off | off | on |
5 | on | off | on |
6 | off | on | on |
7 | on | on | on |
BIOS ADDRESS - SW3 | |||||
Address | Switch 3 | Switch 4 | Switch 5 | Switch 6 | Switch 7 |
C800h | on | on | off | on | on |
CA00h | off | on | off | on | on |
CC00h | on | off | off | on | on |
CE00h | off | off | off | on | on |
D000h | on | on | on | off | on |
D200h | off | on | on | off | on |
D400h | on | off | on | off | on |
D600h | off | off | on | off | on |
D800h | on | on | off | off | on |
DA00h | off | on | off | off | on |
DC00h | on | off | off | off | on |
DE00h | off | off | off | off | on |
E000h | on | on | on | on | off |
E200h | off | on | on | on | off |
E400h | on | off | on | on | off |
E600h | off | off | on | on | off |
E800h | on | on | off | on | off |
EA00h | off | on | off | on | off |
EC00h | on | off | off | on | off |
EE00h | off | off | off | on | off |
MISCELLANEOUS TECHNICAL NOTES |
For termination power, a # 1N5817 diode must be installed at socket CR2 and JP1 must be on. |