THOMAS-CONRAD CORPORATION
TC3042-CX (VERSION 1.0) TCNS 8-BIT
NIC Type | TCNS (Proprietary) |
Transfer Rate | 100Mbps |
Data Bus | 8-bit ISA |
Topology | Star |
Wiring Type | RG62/U 93ohm coaxial |
Boot ROM | Available |
BASE I/O ADDRESS | |||||||
Address | SW3/1 | SW3/2 | SW3/3 | SW3/4 | SW3/5 | SW3/6 | |
» | 2E0h | Off | On | Off | Off | Off | On |
2F0h | Off | On | Off | Off | Off | Off | |
300h | Off | Off | On | On | On | Off | |
350h | Off | Off | On | Off | On | On |
BASE MEMORY ADDRESS | |||||||||
Address | SW1/1 | SW1/2 | SW1/3 | SW1/4 | SW1/5 | SW1/6 | SW1/7 | SW1/8 | |
» | D000h | Off | Off | On | Off | On | On | On | On |
C000h | Off | Off | On | On | On | On | On | On | |
C400h | Off | Off | On | On | On | Off | On | On | |
C800h | Off | Off | On | On | Off | On | On | On | |
CC00h | Off | Off | On | On | Off | Off | On | On | |
D400h | Off | Off | On | Off | On | Off | On | On | |
D800h | Off | Off | On | Off | Off | On | On | On | |
DC00h | Off | Off | On | Off | Off | Off | On | On | |
E000h | Off | Off | Off | On | On | On | On | On |
DIAGNOSTIC LED(S) | |||
LED | Color | Status | Condition |
LED1 | Red | On | Data is being transmitted or received. |
LED1 | Red | Blinking | Network connection is bad |
LED1 | Red | Off | No network connection, or the card is malfunctioning. |
FACTORY CONFIGURED SETTINGS | |
Setting | |
SW3/switch 8 | N/A |
INTERRUPT SETTINGS | |||||||
IRQ | JP6A | JP6B | JP6C | JP6D | JP6E | JP6G | |
» | 2 | Closed | Open | Open | Open | Open | Open |
3 | Open | Closed | Open | Open | Open | Open | |
4 | Open | Open | Closed | Open | Open | Open | |
5 | Open | Open | Open | Closed | Open | Open | |
6 | Open | Open | Open | Open | Closed | Open | |
7 | Open | Open | Open | Open | Open | Closed |
NODE ADDRESS | ||||||||||
Node | SW2/1 | SW2/2 | SW2/3 | SW2/4 | SW2/5 | SW2/6 | SW2/7 | SW2/8 | ||
0 | - | - | - | - | - | - | - | - | ||
» | 1 | Off | On | On | On | On | On | On | On | |
2 | On | Off | On | On | On | On | On | On | ||
3 | Off | Off | On | On | On | On | On | On | ||
4 | On | On | Off | On | On | On | On | On | ||
251 | Off | Off | On | Off | Off | Off | Off | Off | ||
252 | On | On | Off | Off | Off | Off | Off | Off | ||
253 | Off | On | Off | Off | Off | Off | Off | Off | ||
254 | On | Off | Off | Off | Off | Off | Off | Off | ||
255 | Off | Off | Off | Off | Off | Off | Off | Off | ||
Notes: Node address 0 is used for messaging between nodes and must not be used. A total of 255 node address settings are available. The switches are a binary representation of the decimal node addresses. Switch 1 is the Least Significant Bit and switch 8 is the Most Significant Bit. The switches have the following decimal values: switch 1=1, 2=2, 3=4, 4=8, 5=16, 6=32, 7=64, 8=128. Turn off the switches and add the values of the off switches to obtain the correct node address. (On=0, off=1) |
OPERATING MODE | ||
Mode | SW3/switch 7 | |
» | Enhanced Mode | On |
Compatible Mode | Off |
WAIT STATE CONFIGURATION | ||
0 Wait State | JP1 | |
» | Disabled | Open |
Enabled | Closed |