STANDARD MICROSYSTEMS CORPORATION
ARCNET PC120
EAGLE TECHNOLOGIES
RX-NET II
NIC Type | ARCnet |
Transfer Rate | 2.5Mbps |
Data Bus | 8-bit ISA |
Topology | Star |
Wiring Type | RG-62A/U 93ohm coaxial |
Boot ROM | Available |

NODE ADDRESS SELECTION | ||||||||
Node | SW3/1 | SW3/2 | SW3/3 | SW3/4 | SW3/5 | SW3/6 | SW3/7 | SW3/8 |
0 | - | - | - | - | - | - | - | - |
1 | Off | On | On | On | On | On | On | On |
2 | On | Off | On | On | On | On | On | On |
3 | Off | Off | On | On | On | On | On | On |
4 | On | On | Off | On | On | On | On | On |
251 | Off | Off | On | Off | Off | Off | Off | Off |
252 | On | On | Off | Off | Off | Off | Off | Off |
253 | Off | On | Off | Off | Off | Off | Off | Off |
254 | On | Off | Off | Off | Off | Off | Off | Off |
255 | Off | Off | Off | Off | Off | Off | Off | Off |
Note:Node address 0 is used for messaging between nodes and must not be used. A total of 255 node address settings are available. The switches are a binary representation of the decimal node addresses. Switch 1 is the Least Significant Bit and switch 8 is the Most Significant Bit. The switches have the following decimal values: switch 1=1, 2=2, 3=4, 4=8, 5=16, 6=32, 7=64, 8=128. Turn off the switches and add the values of the off switches to obtain the correct node address. (On=0, Off=1) | ||||||||
INTERRUPT REQUEST SELECTION | |||||
IRQ | JP1 | JP2 | JP3 | JP4 | JP5 |
2 | Closed | Open | Open | Open | Open |
3 | Open | Closed | Open | Open | Open |
4 | Open | Open | Closed | Open | Open |
5 | Open | Open | Open | Closed | Open |
7 | Open | Open | Open | Open | Closed |
I/O BASE ADDRESS SELECTION | ||||||
Address | SW2/1 | SW2/2 | SW2/3 | SW2/4 | SW2/5 | SW2/6 |
200h | Off | On | On | On | On | On |
250h | Off | On | On | Off | On | Off |
2A0h | Off | On | Off | On | Off | On |
2E0h | Off | On | Off | Off | Off | On |
2F0h | Off | On | Off | Off | Off | Off |
300h | Off | Off | On | On | On | On |
350h | Off | Off | On | Off | On | Off |
3E0h | Off | Off | Off | Off | Off | Off |
BUFFER ADDRESS SELECTION | ||||||
Address | SW1/1 | SW1/2 | SW1/3 | SW1/4 | SW1/5 | SW1/6 |
C0000h | Off | Off | On | On | On | On |
C4000h | Off | Off | On | On | On | Off |
C8000h | Off | Off | On | On | On | On |
CC000h | Off | Off | On | On | Off | Off |
D0000h | Off | Off | On | Off | On | On |
D4000h | Off | Off | On | Off | On | On |
D8000h | Off | Off | On | Off | Off | On |
DC000h | Off | Off | On | Off | Off | Off |
E0000h | Off | Off | Off | On | On | On |
FACTORY CONFIGURED SETTINGS | |
Switch | Setting |
SW1/7 | On |
SW1/8 | On |