PURE DATA, LTD.
PDI7023-16CAT
NIC Type | Ethernet |
Transfer Rate | 10Mbps |
Data Bus | 16-bit ISA |
Topology | Star Linear bus |
Wiring Type | Unshielded twisted pair RG58A/U 50ohm coaxial AUI transceiver via DB-15 port |
Boot ROM | Not available |

COAXIAL SEGMENT LENGTH | ||
Maximum Length | E1 | |
| » | 200 meters | Closed |
300 meters | Open | |
INTERRUPT REQUEST | |||||||||||
IRQ | E2A | E2B | E2C | E2D | E2E | E2F | E2G | E2H | E2I | E2J | |
2/9 | Open | Open | Open | Open | Closed | Open | Open | Open | Open | Open | |
3 | Open | Open | Open | Open | Open | Open | Open | Open | Open | Closed | |
| » | 4 | Open | Open | Open | Open | Open | Open | Open | Open | Closed | Open |
5 | Open | Open | Open | Open | Open | Open | Open | Closed | Open | Open | |
6 | Open | Open | Open | Open | Open | Open | Closed | Open | Open | Open | |
7 | Open | Open | Open | Open | Open | Closed | Open | Open | Open | Open | |
10 | Open | Open | Open | Closed | Open | Open | Open | Open | Open | Open | |
11 | Open | Open | Closed | Open | Open | Open | Open | Open | Open | Open | |
12 | Open | Closed | Open | Open | Open | Open | Open | Open | Open | Open | |
15 | Closed | Open | Open | Open | Open | Open | Open | Open | Open | Open | |
CABLE TYPE | ||
Type | Isolation Transformer Location | |
| » | Unshielded twisted pair | N/A |
RG58A/U 50ohm coaxial | T2 | |
AUI transceiver via DB-15 port | T3 | |
Note:The cable type is automatically selected, but the isolation transformer must be moved to the proper socket to enable the BNC connector or DB-15 port.
| ||
I/O BASE ADDRESS | ||||
Address | SW1/1 | SW1/2 | SW1/3 | |
260h | On | On | On | |
290h | Off | On | On | |
2E0h | On | Off | On | |
2F0h | Off | Off | On | |
| » | 300h | On | On | Off |
350h | Off | On | Off | |
380h | On | Off | Off | |
3E0h | Off | Off | Off | |
EXTENDED TRANSMIT TIMEOUT | ||
Setting | SW1/5 | |
| » | Enabled | On |
Disabled | Off | |
Note:With this option enabled, if the card is transmitting for an extended amount of time the transmission will be interrupted and continued after a preset time. This keeps one card from dominating the network. | ||
LINK INTEGRITY TEST | ||
Setting | SW1/7 | |
| » | Enabled | On |
Disabled | Off | |
Note:The link integrity test is valid only when the cable type is unshielded twisted pair. | ||
FACTORY CONFIGURED SETTINGS | |
Switch | Setting |
SW1/4 | Off |
SW1/6 | On |
SW1/8 | Off |

DIAGNOSTIC LED(S) | |||
LED | Color | Status | Condition |
LED1 | Green | On | Data is being transmitted or received |
LED1 | Green | Off | Data is not being transmitted or received |
LED2 | Red | On | Card is being accessed by host computer |
LED2 | Red | Off | Card is not being accessed by host computer |
LED3 | Red | On | Collision detected on network |
LED3 | Red | Off | Normal operation |
LED4 | Green | On | Cable type is AUI via DB-15 or RG-58A/U coaxial |
LED4 | Green | Off | Cable type is Twisted pair |