lotus

previous page: PLAN 2000 NIC Network Card Settings and Configuration
  
page up: Network Cards Settings: N
  
next page: MICRONET MASTER BOARD Network Card Settings and Configuration

MEGANET STATION BOARD Network Card Settings and Configuration







NETWORK DEVELOPMENT CORPORATION

MEGANET STATION BOARD

NIC Type

Device Network Architecture (DNA)

Transfer Rate

10Mbps

Data Bus

8-bit ISA

Topology

Linear bus

Wiring Type

Shielded twisted pair

Unshielded twisted pair (1 male, 1 female DB-9 connector)

Boot ROM

Available (Permanently installed)

I/O BASE ADDRESS

Address

JP1A

JP1B

»

2E0h

Open

Open

 

2E8h

Open

Closed

 

3E0h

Closed

Open

 

3E8h

Closed

Closed

INTERRUPT REQUEST

IRQ

JP2A

JP2B

JP2C

JP2D

 

2

Closed

Open

Open

Open

 

3

Open

Closed

Open

Open

 

4

Open

Open

Closed

Open

»

5

Open

Open

Open

Closed

 

Disabled

Pins one of JP2A & JP2B closed

REMOTE BOOT

Setting

JP4

»

Disabled

Pins 1 & 2 closed

 

Enabled

Pins 2 & 3 closed

Note:With remote boot enabled the card will boot from the Meganet Master Board instead of a local drive.

SLOT EIGHT ENABLE

Setting

JP8

»

Disabled

Closed

 

Enabled

Open

Note:If the card is installed in slot 8 of an IBM XT or compatible this option must be enabled.








TOP
previous page: PLAN 2000 NIC Network Card Settings and Configuration
  
page up: Network Cards Settings: N
  