MECER CORPORATION
B363T
NIC Type | Ethernet |
Transfer Rate | 10Mbps |
Data Bus | 16-bit ISA |
Topology | Star |
Wiring Type | Unshielded twisted pair AUI Transceiver via DB-15 port |
Boot ROM | Available |

BASE I/O ADDRESS SELECTION | |
Address | JP2 |
300h | Pins 1 & 2, 3 & 4 closed |
320h | Pins 1 & 2 closed |
340h | Pins 3 & 4 closed |
360h | all open |
INTERRUPT SELECTION | ||
IRQ | JP1 | |
| » | 3 | Pins 15 & 16 closed |
2/9 | Pins 17 & 18 closed | |
4 | Pins 13 & 14 closed | |
5 | Pins 11 & 12 closed | |
6 | Pins 9 & 10 closed | |
7 | Pins 7 & 8 closed | |
10 | Pins 5 & 6 closed | |
11 | Pins 3 & 4 closed | |
12 | Pins 1 & 2 closed | |
BOOT ROM CONFIGURATION | |
Setting | JP3 (pins 7 & 8) |
Disabled | Open |
Enabled | Closed |
ROM ADDRESS | |||
Address | JP3 (pins 1 & 2) | JP3 (pins 3 & 4) | JP3 (pins 5 & 6) |
C0000h | Closed | Closed | Closed |
C4000h | Open | Closed | Closed |
C8000h | Closed | Open | Closed |
CC000h | Open | Open | Closed |
D0000h | Closed | Closed | Open |
D4000h | Open | Closed | Open |
D8000h | Closed | Open | Open |
DC000h | Open | Open | Open |
AT BUS WAIT STATE CONFIGURATION | |
Setting | JP4 |
0 wait states | Closed |
1 wait state | Open |

DIAGNOSTIC LED(S) | |||
LED | Color | Status | Condition |
LED1 | Green | On | Network connection is good |
LED1 | Green | Off | Network connection is broken |
LED2 | Red | On | Data is being received |
LED2 | Red | Off | Data is not being received |
LED3 | Yellow | On | Data is being transmitted |
LED3 | Yellow | Off | Data is not being transmitted |