MADGE NETWORKS, LTD.
SMART 16/4 CLIENT RINGNODE
NIC Type | Token Ring |
Transfer Rate | 4/16Mbps |
Data Bus | 16-bit ISA |
Topology | Ring |
Wiring Type | Shielded/Unshielded twisted pair |
Boot ROM | Available |

BOOT ROM | ||
Setting | SW2/3 | |
| » | Disabled | Off |
Enabled | On | |
COMPATIBILITY MODE | ||
Setting | SW2/6 | |
| » | Normal ISA bus timing | On |
Alternate ISA bus timing | Off | |
Note:Alternate ISA bus timing is used if the host computer is not 100% ISA bus compatible (such as the IBM PS/2 model 30-286) or if the Madge Ringnode diagnostics program fails to locate the NIC. | ||
DMA CHANNEL BUS | ||
Setting | SW2/7 | |
| » | Asynchronous bus (uses host system’s clock) | Off |
Synchronous bus (uses NIC on-board clock) | On | |
Note:The synchronous bus speed is used for systems that have a clock speed less than 10MHz. | ||
EXPANSION SLOT SIZE | ||
Slot Size | SW2/5 | |
| » | Automatic select | On |
Forced 8-bit mode | Off | |
Note:If an 8-bit transfer mode is required and the NIC is installed in a 16-bit slot, use forced 8-bit mode. If the NIC is to be used in a Novell Netware 386 file server, automatic select must be used. | ||
INTERRUPT REQUEST | ||
IRQ | SW1 | |
| » | 3 | Position 7 |
2/9 | Position 8 | |
5 | Position 6 | |
7 | Position 5 | |
10 | Position 4 | |
11 | Position 3 | |
12 | Position 2 | |
15 | Position 1 | |
NETWORK SPEED | ||
Speed | SW2/7 | |
| » | 16Mbps | Off |
4Mbps | On | |
Note:All cards on a segment must have this option set the same. | ||
BASE I/O AND BOOT ROM ADDRESS | ||||
Address | Boot ROM Address | SW2/1 | SW2/2 | |
| » | 0A20-0A2Fh | CC000-CDFFFh | On | On |
1A20-1A2Fh | DC000-DDFFFh | Off | On | |
2A20-2A2Fh | CE000-CFFFFh | On | Off | |
3A20-3A2Fh | DE000-DFFFFh | Off | Off | |
CABLE TYPE | |
Type | LB1 |
Shielded twisted pair (DB-9 connector) | STP |
Unshielded twisted pair (RJ-45 jack) | UTP |