IMC NETWORKS CORPORATION
LANCEIVER/2
Card Type | Ethernet transceiver |
Network Transfer Rate | 10Mbps |
Data Bus | AUI via DB-15 connector |
Topology | Linear Bus |
Wire Type | AUI transceiver via DB-15 port |

CONNECTIONS | |||
Function | Label | Function | Label |
AUI port 1 via DB-15 connector | CN1 | AUI port 2 via DB-15 connector | CN2 |
USER CONFIGURABLE SETTINGS | |||
Setting | Label | Position | |
| » | Factory configured - do not alter | JP1 pins 1 - 2 | Unidentified |
| » | Factory configured - do not alter | JP1 pin 8 | Unidentified |
| » | Factory configured - do not alter | JP1 pins 11 - 30 | Unidentified |
MASTER SQE HEARTBEAT CONFIGURATION | ||
Setting | JP1 | |
| » | Enabled | Pins 4 & 5 closed |
Disabled | Pins 3 & 4 closed | |
PORT 1 SQE HEARTBEAT CONFIGURATION | |
Setting | JP1/pins 6 & 7 |
Enabled | Closed |
Disabled | Open |
PORT 2 SQE HEARTBEAT CONFIGURATION | |
Setting | JP1/pins 9 & 10 |
Enabled | Closed |
Disabled | Open |
DIAGNOSTIC LED(S) | |||
LED | Color | Status | Condition |
JAB1 | Yellow | On | Jabber detected on port 1 |
JAB1 | Yellow | Off | Jabber not detected on port 1 |
XMT1 | Green | On | Port 1 is transmitting data to the network |
XMT1 | Green | Off | Port 1 is not transmitting data to the network |
XMT2 | Green | On | Port 2 is transmitting data to the network |
XMT2 | Green | Off | Port 2 is not transmitting data to the network |
JAB2 | Yellow | On | Jabber detected on port 2 |
JAB2 | Yellow | Off | Jabber not detected on port 2 |
COL | Red | On | Network collision detected |
COL | Red | Off | Network collision not detected |
RCV | Yellow | On | Transceiver is receiving data from the network |
RCV | Yellow | Off | Transceiver is not receiving data from the network |
SQE | Yellow | On | SQE heartbeat signal enabled |
SQE | Yellow | Off | SQE heartbeat signal disabled |
PWR | Green | On | Power is on |
PWR | Green | Off | Power is off |