EMULEX CORPORATION
LIGHTPULSE PCI HOST
Card Type | Network Interface Card |
NIC Type | FDDI |
Maximum Onboard Memory | Unidentified |
Boot ROM | Unidentified |
Network Transfer Rate | Unidentified |
Topology | Star |
Wiring Type | Fiber optic cable, unshielded Twisted Pair |
Data Bus | 32-bit PCI |

CONNECTIONS | |
Function | Label |
80-pin proprietary "GLM" interface connector | CN1 |
Fiber optic connector via 80-pin proprietary "GLM" interface | CN2/A |
UTP on DB9 connector via 80-pin proprietary "GLM" interface | CN2/B |
DIAGNOSTIC LED(S) | ||
Green LED | Yellow LED | Condition |
Off | Off | Wake-up failure (dead board) |
Off | On | Power On Self Test failure (dead board) |
Off | Slow blink (1 Hz) | Wake-up failure |
Off | Fast blink (4 Hz) | Failure in Power On Self Test |
Off | Flashing (irregular) | Power On Self Test processing in progress |
On | Off | Failure while functioning |
On | On | Failure while functioning |
On | Slow blink (1 Hz) | Normal – inactive |
On | Flashing (irregular) | Normal – active |
On | Fast blink (4 Hz) | Normal – busy |
Slow blink | Off | Normal – link down or not yet started |
Slow blink | Slow blink (1 Hz) | Off-line for download |
Slow blink | Fast blink (4 Hz) | Restricted off-line mode (waiting for restart) |
MISCELLANEOUS TECHNICAL NOTES |
If either media or speed is changed, the "GLM" must be changed. |