DANPEX CORPORATION
FE-1400TX
NIC Type | Ethernet |
Transfer Rate | 10/100Mbps |
Data Bus | PCI |
Topology | Star |
Wiring Type | Unshielded twisted pair, shielded twisted pair |
Boot ROM | Not available |

CONNECTIONS | |||
Purpose | Location | Purpose | Location |
100Base-T port | PORT 1 | 10Base-T port | PORT 2 |
INTERRUPT SELECTION | |||||
IRQ | JP2/A | JP2/B | JP2/C | JP2/D | |
| » | A | Closed | Open | Open | Open |
B | Open | Closed | Open | Open | |
C | Open | Open | Closed | Open | |
D | Open | Open | Open | Closed | |
DIAGNOSTIC LED(S) | ||
LED | Status | Condition |
LED1 | On | Data is being transmitted/received at 100Mbps |
LED1 | Off | Data is not being transmitted/received at 100Mbps |
LED2 | On | 100Base-T network connection is good |
LED2 | Off | 100Base-T network connection is broken |
LED3 | On | Data is being transmitted/received at 10Mbps |
LED3 | Off | Data is not being transmitted/received at 10Mbps |
LED4 | On | 10Base-T network connection is good |
LED4 | Off | 10Base-T network connection is broken |