COMTROL CORPORATION
CNIC/2
NIC Type | Ethernet |
Transfer Rate | 10Mbps |
Data Bus | 16-bit ISA |
Topology | Linear Bus, Star |
Wiring Type | RG58A/U 50ohm coaxial |
Boot ROM | Available |

ADDRESS/INTERRUPT SELECT | ||||||
I/O Address | Memory Address | DMA | IRQ | JP3/A | JP3/B | |
| » | 300h | C8000h | 5 | IRQ3 | Closed | Closed |
320h | CC000h | 6 | IRQ4 | Closed | Open | |
340h | C0000h | 7 | IRQ5 | Open | Closed | |
360h | D4000h | 3 | IRQ9 | Open | Open | |
DMA CONFIGURATION | |||||
DACK | JP1/A | JP1/B | JP1/C | JP1/D | |
| » | 5 | Open | Open | Closed | Open |
3 | Open | Open | Open | Closed | |
6 | Open | Closed | Open | Open | |
7 | Closed | Open | Open | Open | |
DMA CONFIGURATION (CONTINUED) | |||||
DRQ | JP2/A | JP2/B | JP2/C | JP2/D | |
| » | 5 | Open | Open | Closed | Open |
3 | Open | Open | Open | Closed | |
6 | Open | Closed | Open | Open | |
7 | Closed | Open | Open | Open | |
BOOT ROM | ||
Setting | JP5 | |
| » | Disabled | Open |
Enabled | Closed | |
INTERRUPT SELECT | |||||
IRQ | JP4/A | JP4/B | JP4/C | JP4/D | |
| » | IRQ5 | Open | Open | Closed | Open |
IRQ3 | Closed | Open | Open | Open | |
IRQ4 | Open | Closed | Open | Open | |
IRQ9 | Open | Open | Open | Closed | |
Disabled | Open | Open | Open | Open | |