COMPAQ COMPUTER CORPORATION
PROLIANT 2000R
Processor | Pentium |
Processor Speed | 66/90MHz |
Chip Set | Unidentified |
Video Chip Set | None |
Maximum Onboard Memory | 512MB (EDO supported) |
Maximum Video Memory | 1MB |
Cache | 256/512KB |
BIOS | Unidentified |
Dimensions | 305mm x 244mm |
I/O Options | Unidentified |
NPU Options | None |
CONNECTIONS | |||
Purpose | Location | Purpose | Location |
Proprietary slots | SL1 – SL4 | External memory card | SL5 |
Note: The location and types of I/O options are unidentified. |
USER CONFIGURABLE SETTINGS | |||
Function | Label | Position | |
» | Factory configured - do not alter | SW4/1 | On |
» | Soft switching mode enabled | SW4/2 | On |
Soft switching mode disabled | SW4/2 | Off | |
» | Keyboard broadcasting mode disabled | SW4/3 | Off |
Keyboard broadcasting mode enabled | SW4/3 | On | |
» | Mouse broadcasting mode disabled | SW4/4 | Off |
Mouse broadcasting mode enabled | SW4/4 | On | |
» | Scan mode enabled | SW4/5 | On |
Scan mode disabled | SW4/5 | Off | |
» | Tiering mode disabled | SW4/6 | Off |
Tiering mode enabled | SW4/6 | On | |
» | Factory configured - do not alter | SW4/7 | Unidentified |
» | Factory configured - do not alter | SW4/8 | Unidentified |
DRAM CONFIGURATION | ||||
Size | Bank 0 | Bank 1 | Bank 2 | Bank 3 |
64MB | (4) 4M x 36 | None | None | None |
128MB | (4) 8M x 36 | None | None | None |
256MB | (4) 16M x 36 | None | None | None |
128MB | (4) 4M x 36 | (4) 4M x 36 | None | None |
256MB | (4) 8M x 36 | (4) 8M x 36 | None | None |
256MB | (4) 4M x 36 | (4) 4M x 36 | (4) 4M x 36 | (4) 4M x 36 |
512MB | (4) 8M x 36 | (4) 8M x 36 | (4) 8M x 36 | (4) 8M x 36 |
Note: The location of banks 0 & 1 is unidentified. Banks 2 & 3 are located on the memory card. |
CACHE CONFIGURATION |
Note: The location of the cache is unidentified. |
MONITOR SELECTION NOTE |
Note: The Proliant 2000R is capable of controlling up to 8 servers, each with their own monitor. To select a monitor type for a specific server, first consult either the 4 or 8 Port Monitor Control Selection Table to determine which switches are used for the configuration.. Then refer to the Server Monitor Selection table to determine the individual switch settings. |
4 PORT MONITOR CONTROL SELECTION | ||
Switch | Controlling switches | Server controlled |
S1 | S1/1 - 4 | 1 |
S1 | S1/5 - 8 | 2 |
S2 | S2/1 - 4 | 3 |
S2 | S2/5 - 8 | 4 |
8 PORT MONITOR CONTROL SELECTION | ||
Switch | Controlling switches | Server controlled |
S1 | S1/1 - 4 | 1 |
S1 | S1/5 - 8 | 2 |
S2 | S2/1 - 4 | 3 |
S2 | S2/5 - 8 | 4 |
S3 | S3/1 - 4 | 5 |
S3 | S3/5 - 8 | 6 |
S4 | S3/1 - 4 | 7 |
S4 | S3/5 - 8 | 8 |
SERVER MONITOR SELECTION | ||||
Type | SW1/1 orSW1/5 | SW1/2 orSW1/6 | SW1/3 orSW1/7 | SW1/4 orSW1/8 |
VGA | Off | Off | On | Off |
Monochrome | Off | Off | On | Off |
VGA | Off | On | Off | Off |
SVGA | Off | On | Off | Off |
SVGA- Compaq 430 | On | On | Off | On |
XVGA – IBM8512 | Off | On | Off | Off |
XVGA – IBM8513 | Off | On | Off | Off |
XVGA – IBM8514 | On | On | Off | Off |
XVGA – IBM8515 | On | Off | Off | Off |
Note: Each bank of switches must reflect the type of monitor configured on the server. |