WISECOM, INC.
DATA/FAX/VOICE MODEM 14.4 (REV.1)
Card Type | Fax, Modem (asynchronous), Voice |
Chip Set | Cirrus Logic |
I/O options | Voice |
Maximum Data Rate | 14.4Kbps |
Maximum Fax Rate | 14.4Kbps |
Data Bus | 8-bit ISA |
Fax Class | Class I |
Data Modulation Protocol | Bell 103A/212A ITU-T V.21, V.22, V.22bis, V.32, V.32bis |
Fax Modulation Protocol | ITU-T V.17, V.21CH2, V.27ter, V.29 |
Error Correction/Compression | MNP5, V.42, V.42bis |
CONNECTIONS | ||||||
Function | Label | Function | Label | |||
Line in | CN1 | Line out | CN2 |
SERIAL PORT ADDRESS | ||
Setting | JP8/1 | JP8/2 |
COM1 (3F8h) | Pins 1 & 2 closed | Pins 1 & 2 closed |
COM2 (2F8h) | Pins 2 & 3 closed | Pins 1 & 2 closed |
COM3 (3E8h) | Pins 1 & 2 closed | Pins 2 & 3 closed |
í COM4 (2E8h) | Pins 2 & 3 closed | Pins 2 & 3 closed |
INTERRUPT | ||||
Setting | JP8/3 | JP8/4 | JP8/5 | JP8/6 |
2 | Closed | Open | Open | Open |
í 3 | Open | Closed | Open | Open |
4 | Open | Open | Closed | Open |
5 | Open | Open | Open | Closed |
Proprietary AT Command Set
ACCEPT RELIABLE MODE | |
Type: | Immediate |
Format: | AT [cmds] \U [cmds] |
Description: | Accepts remote modem’s request for reliable link |
AUTO FALL FORWARD/FALLBACK | |
Type: | Configuration |
Format: | AT [cmds] %Gn [cmds] |
Description: | Selects auto fallback/fall forward |
Command | Function |
í %G0 | Fallback/fall forward enabled |
%G1 | Fallback/fall forward disabled |
AUTO-RELIABLE FALLBACK CHARACTER | |
Type: | Configuration |
Format: | AT [cmds] %An [cmds] |
Default: | Unidentified |
Range: | 0-127 |
Unit: | ASCII |
Description: | Sets the character used as the auto-reliable fallback character. %A0 will disable this function. |
AUTO-RELIABLE TIME BUFFER CONFIGURATION | |
Type: | Configuration |
Format: | AT [cmds] \Cn [cmds] |
Description: | Controls the handling of incoming data during auto-reliable time period |
Command | Function |
í \C0 | Data is discarded |
\C1 | Data is buffered |
\C2 | Data is discarded, modem returns to normal mode on receiving auto-reliable fallback character. |
AUTO-RETRAIN | |
Type: | Configuration |
Format: | AT [cmds] %En [cmds] |
Description: | Selects auto-retrain mode |
Command | Function |
%E0 | Auto-retrain disabled |
í %E1 | Auto-retrain enabled |
BIT MAPPED REGISTERS | |
Register | Default |
S14 | Unidentified |
S21 | Unidentified |
S22 | Unidentified |
S23 | Unidentified |
S27 | Unidentified |
BREAK SEND | |
Type: | Configuration |
Format: | AT [cmds] \Bn [cmds] |
Range: | 0-9 |
Unit: | .1 seconds |
Description: | Sends break to modem |
BREAK TYPE | |
Type | Configuration |
Format | AT [cmds] \Kn [cmds] |
Default | 5 |
Range | 0-5 |
Description | Configures action of break signal |
CALLING TONE | |
Type: | Configuration |
Format: | AT [cmds] -Cn [cmds] |
Description: | Controls whether the DTE will allow the modem to send a 1300Hz calling tone when originating. |
Command | Function |
í -C0 | Disable calling tone |
-C1 | Enable calling tone |
COMPRESSION | |
Type: | Configuration |
Format: | AT [cmds] %Cn [cmds] |
Description: | Selects data compression |
Command | Function |
%C0 | Data compression disabled |
í %C1 | MNP5 enabled |
CONNECT MODE | |
Type: | Configuration |
Format: | AT [cmds] \Nn [cmds] |
Description: | Sets connect mode |
Command | Function |
\N0 | Normal mode enabled |
\N1 | Direct mode enabled |
\N2 | MNP mode enabled |
í \N3 | Auto-reliable mode enabled |
\N4 | V.42 mode enabled |
CONVERT TO RELIABLE MODE | |
Type: | Immediate |
Format: | AT [cmds] \Y [cmds] |
Description: | Initiates reliable mode link |
EXTENDED RESULT CODES | |
Type: | Configuration |
Format: | AT [cmds] \Vn [cmds] |
Description: | Selects extended result codes |
Command | Function |
\V0 | Extended result codes disabled |
\V1 | Reliable result codes enabled |
í \V2 | Error control and compression result codes enabled |
FLOW CONTROL | |
Type: | Configuration |
Format: | AT [cmds] \Gn [cmds] |
Description: | Selects modem port flow control |
Command | Function |
í \G0 | Flow control disabled |
\G1 | Flow control enabled |
FLOW CONTROL TYPE | |
Type: | Configuration |
Format: | AT [cmds] \Qn [cmds] |
Description: | Sets type of flow control used by modem |
Command | Function |
\Q0 | Flow control disabled |
\Q1 | XON/XOFF flow control enabled |
\Q2 | CTS flow control to DTE enabled |
í \Q3 | RTS/CTS flow control enabled |
INACTIVITY TIMER | |
Type: | Configuration |
Format: | AT [cmds] \Tn [cmds] |
Default: | 0 |
Range: | 0-90 |
Unit: | 1 minute |
Description: | Sets the length of time that the modem does not receive information before it disconnects. |
INACTIVITY TIMER | |
Type: | Register |
Format: | AT [cmds] S90=n [cmds] |
Default: | 0 |
Range: | 0-255 |
Unit: | 1 second |
Description: | Sets the length of time that the modem does not receive information before it disconnects. S90=0 will disable. |
LOCK SERIAL PORT | |
Type: | Configuration |
Format: | AT [cmds] \Jn [cmds] |
Description: | Sets operation of serial port speed |
Command | Function |
í \J0 | Serial speed locked |
\J1 | Serial speed follows connect speed |
MAXIMUM BLOCK SIZE FOR TRANSMISSION | |
Type: | Configuration |
Format: | AT [cmds] \An [cmds] |
Description: | Sets the maximum transmittable block size |
Command | Function |
\A0 | MNP block size is 64 characters |
\A1 | MNP block size is 128 characters |
\A2 | MNP block size is 192 characters |
í \A3 | MNP block size is 256 characters |
ON-LINE IN RELIABLE MODE | |
Type: | Immediate |
Format: | AT [cmds] \O [cmds] |
Description: | Returns to on-line and requests reliable mode connection. |
RETURN TO RELIABLE MODE | |
Type: | Immediate |
Format: | AT [cmds] \Z [cmds] |
Description: | Ends reliable mode link and initiate return to normal mode |
TEST MODES | ||
Format | AT [cmds] S16=n [cmds] | |
Default: | Unidentified | |
Range: | Unidentified | |
Unit: | Bit-mapped | |
Description: | Controls loopback tests, analog, digital, remote digital, and self tests. | |
Bit | Value | Function |
0 | 0 1 | Local analog loopback not in progress Local analog loopback in progress |
1 | 0 | Not used |
2 | 0 1 | Local digital loopback not in progress Local digital loopback in progress |
3 | 0 1 | Modem not in remote digital loopback Remote digital loopback in progress |
4 | 0 1 | Remote digital loopback not requested Remote digital loopback requested |
5 | 0 1 | Remote digital loopback w/ self-test not in progress Remote digital loopback w/ self-test in progress |
6 | 0 1 | Local analog loopback w/ self-test not in progress Local analog loopback w/ self-test in progress |
V.42 DETECTION PHASE | |
Type: | Configuration |
Format: | AT [cmds] -Jn [cmds] |
Description: | Controls V.42 detection |
Command | Function |
-J0 | V.42 detection disabled |
í -J1 | V.42 detection enabled |
V.42bis COMPRESSION CONTROL | |
Type: | Configuration |
Format: | AT [cmds] "Hn [cmds] |
Description: | Controls V.42bis data compression |
Command | Function |
"H0 | V.42bis disabled |
"H1 | V.42bis when transmitting enabled |
"H2 | V.42bis when receiving enabled |
í "H3 | V.42bis when transmitting/receiving enabled |
V.42bis MAXIMUM STRING LENGTH | |
Type: | Immediate |
Format: | AT [cmds] "Closed [cmds] |
Default: | 16 |
Range: | 6-250 |
Unit: | Characters |
Description: | Selects string size for V.42bis compression |
XON/XOFF PASS-THROUGH | |
Type: | Configuration |
Format: | AT [cmds] \Xn [cmds] |
Description: | Selects whether XON/XOFF signals are sent to remote modem |
Command | Function |
í \X0 | XON/XOFF signals trapped by local modem |