U.S. ROBOTICS, INC.
SPORTSTER 28,800 EXTERNAL
Modem Type | Data (synchronous/asynchronous)/Fax |
Maximum Data Rate | 28.8Kbps |
Maximum Fax Rate | 14.4Kbps |
Data Bus | External |
Fax Class | Class I & II |
Data Modulation Protocol | Bell 103A/212A ITU-T V.22, V.22bis, V.23, V.32, V.32bis, V.25 |
Fax Modulation Protocol | ITU-T V.17, V.21CH2, V.27ter, V.29 |
Error Correction/Compression | MNP5, V.42, V.42bis |
CONNECTIONS | |||
Purpose | Location | Purpose | Location |
Line out | CN3 | DC power | CN1 |
Line in | CN4 | Volume | R1 |
RS-232/422 | CN2 | Power switch | SW2 |
DTR SIGNAL | |
Setting | SW1/1 |
» DTR normal | Off |
DTR forced high | On |
RESULT CODES | |
Setting | SW1/2 |
» Verbal result codes enabled | Off |
Numeric result codes enabled | On |
RESULT CODES DISPLAY | |
Setting | SW1/3 |
» Enabled | On |
Disabled | Off |
ECHO DISPLAY | |
Setting | SW1/4 |
» Enabled | Off |
Disabled | On |
AUTO ANSWER | |
Setting | SW1/5 |
» Disabled | On |
Enabled | Off |
CARRIER DETECT | |
Setting | SW1/6 |
» CD normal | Off |
CD forced high | On |
SOFTWARE RESET | |
Setting | SW1/7 |
» CD normal | Off |
CD forced high | On |
AT COMMAND SET | |
Setting | SW1/8 |
Enabled | On |
Disabled | Off |
DIAGNOSTIC LED(S) | ||||
LED | Color | Status | Mode | Condition |
AA | Red | On | Answer | Auto-answer enabled |
AA | Red | Off | N/A | Auto-answer disabled |
AA | Red | Blinking | N/A | Phone is ringing |
CD | Red | On | N/A | Carrier signal detected |
CD | Red | Off | N/A | Carrier signal not detected |
RD | Red | Blinking | N/A | Modem is receiving data or sending result codes |
RD | Red | Off | N/A | Modem is not receiving data |
SD | Red | Blinking | N/A | Modem is transmitting data |
SD | Red | Off | N/A | Modem is not transmitting data |
TR | Red | On | N/A | DTR signal is high |
TR | Red | Off | N/A | DTR signal is low |
CS | Red | On | N/A | CTS high |
CS | Red | Off | N/A | CTS normal |
ARQ/FAX | Red | On | Data | Error control connection established |
ARQ/FAX | Red | Blinking | Data | Error control data is being transmitted |
ARQ/FAX | Red | Blinking | Fax | Modem is connected in FAX mode |
Proprietary AT Command Set
BIT-MAPPED REGISTER S13 | |||
Format: | AT [cmds] S13=n [cmds] | ||
Example: | ATS13=13 <CR> | ||
Default: | 0 | ||
Range: | 0 - 89 | ||
Unit: | Bit-mapped | ||
Description: | Controls DTR reset, DTR dialing, reset dialing, and MNP3. | ||
Bit | Value | Function | |
0 | » 0 1 | DTR normal. Reset on low DTR. | |
1 | » 0 | Not used. | |
2 | » 0 | Not used. | |
3 | » 0 1 | DTR dialing disabled. DTR dialing enabled. | |
4 | » 0 1 | Reset dialing disabled. Reset dialing enabled. | |
5 | » 0 | Not used. | |
6 | » 0 1 | MNP 3 enabled. MNP 3 disabled. | |
7 | » 0 | Not used. |
BIT-MAPPED REGISTER S15 | |||
Format: | AT [cmds] S15=n [cmds] | ||
Example: | ATS15=13 <CR> | ||
Default: | 0 | ||
Range: | 0 - 56 | ||
Unit: | Bit-mapped | ||
Description: | Controls non-error-correcting mode buffer, MNP4, and BS/DEL switch. | ||
Bit | Value | Function | |
0 | » 0 | Not used. | |
1 | » 0 | Not used. | |
2 | » 0 | Not used. | |
3 | » 0 1 | Non-error-correcting mode transmit buffer set to 1.5KB. Non-error-correcting mode transmit buffer set to 128 bytes. | |
4 | » 0 1 | MNP 4 enabled. MNP 4 disabled. | |
5 | » 0 1 | Use backspace key for delete disabled. Use backspace key for delete enabled. |
BIT-MAPPED REGISTER S27 | |||
Format: | AT [cmds] S27=n [cmds] | ||
Example: | ATS27=139 <CR> | ||
Default: | 0 | ||
Range: | 0 - 191 | ||
Unit: | Bit-mapped | ||
Description: | Controls V.21, V.32 encoding and modulation, V.42 answer tone and handshake, and 9600 result codes. | ||
Bit | Value | Function | |
0 | » 0 1 | V.21 disabled. V.21 enabled. | |
1 | » 0 1 | V.32 trellis coding disabled. V.32 trellis coding enabled. | |
2 | » 0 1 | V.32 modulation enabled. V.32 modulation disabled. | |
3 | » 0 1 | 2100Hz answer tone enabled. 2100Hz answer tone disabled. | |
5, 4 | » 00 01 10 11 | V.42 detect, LAPM and MNP enabled. V.42 detect and LAPM enabled. MNP enabled. LAPM enabled. | |
6 | » 0 | Not used. | |
7 | » 0 1 | Actual result codes displayed. Force 9600 result codes. |
COMPRESSION AND ERROR CORRECTION | |||
Format: | AT [cmds] S51=n [cmds] | ||
Example: | ATS51=3 <CR> | ||
Default: | 0 | ||
Range: | 0 - 7 | ||
Unit: | Bit-mapped | ||
Description: | Selects compression and error correction for specific modulations. | ||
Bit | Value | Function | |
0 | » 0 1 | MNP/V.42 enabled during V.22 operation. MNP/V.42 disabled during V.22 operation. | |
1 | » 0 1 | MNP/V.42 enabled during V.22bis operation. MNP/V.42 disabled during V.22bis operation. | |
2 | » 0 1 | MNP/V.42 enabled during V.32bis operation. MNP/V.42 disabled during V.32bis operation. |
BIT-MAPPED REGISTER S56 | |||
Format: | AT [cmds] S56=n [cmds] | ||
Example: | ATS56=139 <CR> | ||
Default: | 0 | ||
Range: | 0 - 223 | ||
Unit: | Bit-mapped | ||
Description: | Controls non-linearing coding, TX level deviation, pre-emphasis, pre-coding, shaping, V.34, and V.FC. | ||
Bit | Value | Function | |
0 | » 0 1 | Non linearing coding enabled. Non linearing coding disabled. | |
1 | » 0 1 | TX level deviation enabled. TX level deviation disabled. | |
2 | » 0 1 | Pre-emphasis enabled. Pre-emphasis disabled. | |
3 | » 0 1 | Pre-coding enabled. Pre-coding disabled. | |
4 | » 0 1 | Shaping enabled. Shaping disabled. | |
5 | » 0 | Not used. | |
6 | » 0 1 | V.34 enabled. V.34 disabled. | |
7 | » 0 1 | V.FC enabled. V.FC disabled. |
BREAK LENGTH | |
Type: | Register |
Format: | AT [cmds] S21=n [cmds] |
Example: | ATS21=20 <CR> |
Default: | 10 |
Range: | 0-255 |
Unit: | 10 ms |
Description: | Sets the length of error correction mode breaks sent from DCE to DTE in ARQ mode. |
BREAK TYPE | |
Type: | Configuration |
Format: | AT [cmds] &Yn [cmds] |
Example: | AT &Y0 <CR> |
Description: | Configures action of break signal. |
Command | Function |
&Y0 | Break empties buffer. |
» &Y1 | Break empties buffer and is sent immediately. |
&Y2 | Break does not empty buffer and is sent immediately. |
CONNECTION SPEED UPPER LIMIT | |
Type: | Configuration |
Format: | AT [cmds] &Nn [cmds] |
Example: | AT &N1 DT555-1212 <CR> |
Description: | Sets required connection speed if &U is set to 0. Otherwise, sets fastest allowed connection speed. |
Command | Function |
» &N0 | Variable. |
&N1 | 300bps |
&N2 | 1200bps |
&N3 | 2400bps |
&N4 | 4800bps |
&N5 | 7200bps |
&N6 | 9600bps |
&N7 | 12Kbps |
&N8 | 14.4Kbps |
&N9 | 16.8Kbps |
&N10 | 19.2Kbps |
&N11 | 21.6Kbps |
&N12 | 24Kbps |
&N13 | 26.4Kbps |
&N14 | 28.8Kbps |
CONNECTION SPEED LOWER LIMIT | |
Type: | Configuration |
Format: | AT [cmds] &Un [cmds] |
Example: | AT &U1 DT555-1212 <CR> |
Description: | Sets slowest allowed connection speed if &N is set to 1 or higher. |
Command | Function |
» &U0 | Disabled. |
&U1 | 300bps |
&U2 | 1200bps |
&U3 | 2400bps |
&U4 | 4800bps |
&U5 | 7200bps |
&U6 | 9600bps |
&U7 | 12000bps |
&U8 | 14400bps |
&U9 | 16800bps |
&U10 | 19200bps |
&U11 | 21600bps |
&U12 | 24000bps |
&U13 | 26400bps |
&U14 | 28800bps |
ERROR CONTROL MODE | |
Type: | Configuration |
Format: | AT [cmds] &Mn [cmds] |
Example: | AT &M1 %C1 <CR> |
Description: | Selects active error-control protocols. |
Command | Function |
&M0 | Normal mode, error control disabled. |
» &M4 | Normal/ARQ. |
&M5 | ARQ mode. |
ESCAPE CHARACTER RESPONSE | |
Type: | Register |
Format: | AT [cmds] S14=n [cmds] |
Example: | ATS14=0 <CR> |
Default: | 0 |
Description: | Controls reaction to escape character. |
Command | Function |
» S14=0 | Normal operation. |
S14=1 | When +++ is received, modem goes on hook, enters command state and sends NO CARRIER result code. |
EXTENDED RESULT CODES | |
Type: | Configuration |
Format: | AT [cmds] &An [cmds] |
Example: | AT &A1 %C1 <CR> |
Description: | Selects extended result codes. |
Command | Function |
&A0 | Extended result codes disabled. |
&A1 | ARQ result codes enabled. |
&A2 | V.32 result code enabled. |
» &A3 | Error correction and compression result codes enabled. |
FLOW CONTROL CHARACTER - XON | |
Type: | Register |
Format: | AT [cmds] S22=n [cmds] |
Example: | ATS22=20 <CR> |
Default: | 17 |
Range: | 0-127 |
Unit: | ASCII |
Description: | Sets the character used to represent XON. |
FLOW CONTROL CHARACTER - XOFF | |
Type: | Register |
Format: | AT [cmds] S23=n [cmds] |
Example: | ATS23=20 <CR> |
Default: | 19 |
Range: | 0-127 |
Unit: | ASCII |
Description: | Sets the character used to represent XOFF. |
FLOW CONTROL PASSTHROUGH | |
Type: | Configuration |
Format: | AT [cmds] &In [cmds] |
Example: | AT &I0 &W <CR> |
Description: | Allows modem to act on, then transmit XON/XOFF characters. |
Command | Function |
» &I0 | Software flow control disabled. |
&I1 | XON/XOFF passthrough enabled. |
&I2 | XON/XOFF passthrough disabled. |
FLOW CONTROL TYPE | |
Type: | Configuration |
Format: | AT [cmds] &Hn [cmds] |
Example: | AT &H0 A <CR> |
Description: | Sets type of flow control used by modem. |
Command | Function |
&H0 | Flow control disabled. |
» &H1 | CTS/RTS flow control enabled. |
&H2 | XON/XOFF flow control enabled. |
&H3 | CTS/RTS and XON/XOFF flow control enabled. |
HELP SCREENS | |
Type: | Immediate |
Format: | AT <prefix>$ |
Example: | AT &$ <CR> |
Description: | Shows command help screens for all commands beginning with the given prefix, or no prefix if none is given. |
Command | Function |
$ | Shows AT help screen. |
&$ | Shows AT& help screen. |
INACTIVITY TIMER | |
Type: | Register |
Format: | AT [cmds] S19=n [cmds] |
Example: | ATS19=20 <CR> |
Default: | 0 |
Range: | Unidentified |
Unit: | 1 minute |
Description: | Sets the length of time that the modem does not receive information before it disconnects. |
LOCK SERIAL PORT | |
Type: | Configuration |
Format: | AT [cmds] &Bn [cmds] |
Example: | AT &N9 &B0 <CR> |
Description: | Sets operation of serial port speed. |
Command | Function |
&B0 | Serial speed follows connect speed. |
» &B1 | Serial speed locked. |
&B2 | Serial speed locked in ARQ mode only. |
MAPPING | |||
Format: | AT [cmds] S55=n [cmds] | ||
Example: | ATS55=13 <CR> | ||
Default: | 0 | ||
Range: | 0 - 15 | ||
Unit: | Bit-mapped | ||
Description: | Controls mapping. | ||
Bit | Value | Function | |
0 | » 0 1 | 8S-2D map enabled. 8S-2D map disabled. | |
1 | » 0 1 | 16S-4D map enabled. 16S-4D map disabled. | |
2 | » 0 1 | 32S-2D map enabled. 32S-2D map disabled. | |
3 | » 0 1 | 64S-4D map enabled. 64S-4D map disabled. |
REPORT INFORMATION | |
Type: | Immediate |
Format: | AT [cmds] In [cmds] |
Example: | AT I1 O <CR> |
Description: | Displays modem properties. |
Command | Function |
I0 | Reports product code. |
I1 | Reports ROM checksum result. |
I2 | Reports RAM checksum result. |
I3 | Reports firmware version. |
I4 | Reports current command settings. |
I5 | Reports current NVRAM settings. |
I6 | Reports current connection’s statistics. |
I7 | Reports configuration. |
BAUD RATE | |||
Format: | AT [cmds] S54=n [cmds] | ||
Example: | ATS54=139 <CR> | ||
Default: | 0 | ||
Range: | 0 - 255 | ||
Unit: | Bit-mapped | ||
Description: | Controls baud rate. | ||
Bit | Value | Function | |
0 | » 0 1 | 2400 baud rate enabled. 2400 baud rate disabled. | |
1 | » 0 1 | 2743 baud rate enabled. 2743 baud rate disabled. | |
2 | » 0 1 | 2800 baud rate enabled. 2800 baud rate disabled. | |
3 | » 0 1 | 3000 baud rate enabled. 3000 baud rate disabled. | |
4 | » 0 1 | 3200 baud rate enabled. 3200 baud rate disabled. | |
5 | » 0 1 | 3429 baud rate enabled. 3429 baud rate disabled. | |
6 | » 0 1 | Call indicate during V.34 operation enabled. Call indicate during V.34 operation disabled. | |
7 | » 0 1 | V.8 during V.34 operation enabled. V.8 during V.34 operation disabled. |
TONE DIALING TEST | |
Type: | Register |
Format: | AT [cmds] S16=n [cmds] |
Example: | ATS16=1 <CR> |
Description: | Selects the tone dialing test |
Command | Function |
» S16=0 | Tone dialing test disabled. |
S16=1 | Tone dialing test enabled. |
V.32 AND V.32bis MODULATIONS | |||
Format: | AT [cmds] S34=n [cmds] | ||
Example: | ATS34=13 <CR> | ||
Default: | 6 | ||
Range: | 0 - 15 | ||
Unit: | Bit-mapped | ||
Description: | Controls V.32 and V.32bis modulations. | ||
Bit | Value | Function | |
0 | » 0 1 | V.32bis enabled. V.32bis disabled. | |
1 | » 1 | Not used. | |
2 | » 1 | Not used. | |
3 | » 0 1 | V.32 modulation disabled. V.32 modulation enabled. |
V.32 HANDSHAKE TIME | |
Type: | Register |
Format: | AT [cmds] S28=n [cmds] |
Example: | ATS28=20 <CR> |
Default: | 8 |
Range: | 0-255 |
Unit: | .1 second |
Description: | Sets length of V.32 handshake. |