RAD DATA COMMUNICATIONS
CMN-C8H/V.24, CMN-C8H/V.35, CMN-C8H/X.21, CMN-C8H/530
Card Type | Modem (synchronous/asynchronous) |
Chipset | Unidentified |
Data Rate | 56Kbps/64Kbps |
Data Modulation | Unidentified |
Data Bus | Serial |

CONNECTIONS | |||
Function | Label | Function | Label |
V.24, V.35, X.21, or RS-530 serial port via DB-25 connector | CN1 | Unidentified | CN3 |
Telephone line out | CN2 | Loopback test switch | SW6 |
Note: Standard V.35 or X.21 connector is provided on an included adapter cable. | |||
USER CONFIGURABLE SETTINGS | ||
Setting | Label | Position |
í Line speed set to 64Kbps | SW1/4 | Off |
Line speed set to 56Kbps | SW1/4 | On |
í Stop bit shortening for asynchronous mode set to 25% | SW1/5 | Off |
Stop bit shortening for asynchronous mode set to 12.5% | SW1/5 | On |
í DCD forced high | SW2/2 | On |
DCD follows RTS | SW2/2 | Off |
í Pin 18 of CN1 has no function | SW2/3 | Off |
Pin 18 of CN1 begins local analog loopback test | SW2/3 | On |
í Pin 21 of CN1 has no function | SW2/4 | Off |
Pin 21 of CN1 begins remote digital loopback test | SW2/4 | On |
CLOCK SOURCE SELECTION | |||
Setting | SW1/1 | SW1/2 | SW1/3 |
í Internal clock source | Off | Off | Off |
External clock source | On | Off | Off |
Received clock source | Off | Off | On |
Asynchronous mode | Off | On | Off |
DATA LENGTH SELECTION | ||
Setting | SW1/6 | SW2/1 |
8 bits | Off | Off |
9 bits | Off | On |
í 10 bits | On | Off |
11 bits | On | On |
SERIAL PORT CONFIGURATION | |||
Setting | SW3 | SW4 | SW5 |
í DCE | On | On | On |
DTE | Off | Off | Off |
DIAGNOSTIC LED(S) | |||
LED | Color | Status | Condition |
PWR | Green | On | Power is on |
PWR | Green | Off | Power is off |
XMT | Yellow | On | Modem is transmitting data |
XMT | Yellow | Off | Modem is not transmitting data |
RCV | Yellow | On | Modem is receiving data |
RCV | Yellow | Off | Modem is not receiving data |
DCD | Yellow | On | Carrier signal detected |
DCD | Yellow | Off | Carrier signal not detected |
TST | Red | On | Modem is in test mode |
TST | Red | Off | Modem is not in test mode |
MISCELLANEOUS TECHNICAL NOTE |
This card is intended for use in the CMN-16 rack-mount system. The bus is used only for supplying power for the card. All other card functions are accessed through the serial port. |