POWERCOM AMERICA, INC.
PM3314I (SWITCH VERSION)
Card Type | Modem (asynchronous/synchronous) |
Chipset | Rockwell |
Maximum Data Rate | 33.6Kbps |
Maximum Fax Rate | 14.4Kbps |
Data Modulation | Bell 103A/212A ITU-T V.21, V.22, V.22bis, V.23, V.32, V.32bis, V.34 Rockwell V.FC |
Fax Modulation | ITU-T V.17, V.21CH2, V.27ter, V.29 |
Error Correction/Compression | MNP5, V.42, V.42bis |
Fax Class | Class I & II |
Data Bus | 8-bit ISA |
Card Size | Full height, one-third length |

CONNECTIONS | |||
Function | Label | Function | Label |
Telephone line | CN1 | Telephone line | CN2 |
BASE I/O ADDRESS SELECTION | ||
Setting | SW1/3 | SW1/4 |
3F8h (COM1:) | Closed | Closed |
2F8h (COM2:) | Closed | Open |
3E8h (COM3:) | Open | Closed |
2E8h (COM4:) | Open | Open |
INTERRUPT SELECTION | |||||
Setting | JP1 | JP2 | JP3 | SW1/1 | SW1/2 |
2 | Open | Open | Closed | Open | Open |
3 | Open | Open | Open | Closed | Open |
4 | Open | Open | Open | Open | Closed |
5 | Open | Closed | Open | Open | Open |
7 | Closed | Open | Open | Open | Open |
SUPPORTED STANDARD COMMANDS |
Basic AT Commands |
+++, ‘comma’, A/ |
A, B, E, H, L, M, N, O, P, Q, T, V, W, X, Y, Z |
&C, &D, &F, &J, &K, &L, &M, &P, &Q, &T, &V, &W, &Y, &Z |
Extended AT Commands |
\A, \B, \G, \J, \L, \N, \O, \T, \U, \Z |
%C, %E, %Q |
Special AT Commands |
+MS |
S-Registers |
S0, S1, S2, S3, S4, S5, S6, S7, S8, S9, S10, S11, S12, S14, S16, S18, S25, S26 |
S30, S36, S38, S39, S46, S48, S82, S86, S91, S95 |
Note: See MHI help file for complete information. |
UNIDENTIFIED COMMANDS | |
Command | Default |
S21 | Unidentified |
S22 | Unidentified |
S23 | Unidentified |
S27 | Unidentified |
S37 | 0 |
S40 | 57 |
S41 | 1 |
S49 | 8 |
S50 | 255 |
Proprietary AT Command Set
AUTOSYNC OPTIONS | ||
Type: | Register | |
Format | AT [cmds] S19=n [cmds] | |
Default: | 26 | |
Range: | 0 - 30 | |
Description: | Controls autosync protocol, HDLC address detection, bit coding, and HDLC idle. | |
Bit | Value | Function |
0 | 0 | Not used |
1 | 0 í 1 | Binary synchronous protocol used. HDLC protocol used. |
2 | í 01 | HDLC address detect disabled. HDLC address detect enabled. |
3 | 0 í 1 | NRZI bit coding used. NRZ bit coding used. |
4 | 0 í 1 | HDLC idle sends MARK. HDLC idle sends FLAG or SYNC. |
AUTOSYNC HDLC ADDRESS | |
Type: | Register |
Format: | AT [cmds] S20=n [cmds] |
Default: | 0 |
Range: | 0-255 |
Unit: | Unidentified |
Description: | Sets the HDLC address and binary synchronous character. |
BREAK TYPE | |
Type: | Configuration |
Format: | AT [cmds] \Kn [cmds] |
Description: | Configures action of break signal. |
Command | Function |
\K0 | Online command mode enabled, break not sent to remote modem. |
\K1 | Break sent to remote modem and buffers cleared. |
\K3 | Break sent to remote modem immediately. |
\K5 | Break sent with transmitted data. |
DIAL | |
Type: | Immediate |
Format: | AT [cmds] D<#>;[cmds] |
Description: | Dials the telephone number indicated according to any modifiers included in the string. |
Note: | Any combination of modifiers can be used to produce the desired dial functions in sequence. |
Command | Function |
DL | Re-dial last number. |
DP | Pulse dialing enabled. |
DR | Answer mode enabled; originate mode disabled following handshake initiation. |
DS=n | Dial stored telephone number n. |
DT | Tone dialing enabled. |
DW | Dialing resumed following dial tone detection. |
D, | Dialing paused for amount of time specified in S8 register. |
D! | Flash function initiated. Modem commanded to go off-hook for specified time before returning on-hook. |
D@ | Wait for Quiet Answer function enabled. Modem waits until a "quiet answer," a ring-back signal followed by silence up to the time specified in S7, is received prior to executing the rest of the dial string. |
D^ | Enable calling tone for this call. |
D; | Modem returned to idle state after dialing. The semicolon can only be placed at the end of the dial command. |
DISPLAY INFORMATION | |
Type: | Immediate |
Format: | AT [cmds] In [cmds] |
Description: | Displays information requested about the modem. |
Command | Function |
I0 | Displays product identification code. |
I1 | Displays ROM checksum. |
I2 | Tests and displays ROM checksum result. |
I3 | Displays firmware revision. |
I4 | Displays product capabilities. |
V.42bis COMPRESSION CONTROL | |
Type: | Configuration |
Format: | AT [cmds] %Mn [cmds] |
Description: | Controls V.42bis data compression. |
Command | Function |
%M0 | V.42bis disabled. |
%M1 | V.42bis enabled on transmit only. |
%M2 | V.42bis enabled on receive only. |
%M3 | V.42bis enabled. |
V.42bis DICTIONARY CLEAR | |
Type: | Immediate |
Format: | AT [cmds] %P [cmds] |
Description: | Resets the V.42bis dictionary to its initial state upon connection. |
V.42bis DICTIONARY SIZE | |
Type: | Configuration |
Format: | AT [cmds] %Dn [cmds] |
Description: | Selects the size of the V.42bis dictionary. |
Command | Function |
%D0 | 512 byte dictionary selected. |
%D1 | 1024 byte dictionary selected. |
%D2 | 2048 byte dictionary selected. |
%D3 | 4096 byte dictionary selected for unidirectional compression only. |
V.42bis MAXIMUM STRING LENGTH | |
Type: | Immediate |
Format: | AT [cmds] %Sn [cmds] |
Default: | 32 |
Range: | 6-64 |
Unit: | 1 byte |
Description: | Selects string size for V.42bis compression |