POWERCOM AMERICA, INC.
PM33V14E (ROCKWELL)
Card Type | Modem (asynchronous) |
Chipset | Rockwell |
I/O Options | Microphone, microphone in, speaker out, voice, speakerphone, SVD |
Maximum Data Rate | 33.6Kbps |
Maximum Fax Rate | 14.4Kbps |
Data Modulation | Unidentified |
Fax Modulation | Unidentified |
Error Correction/Compression | MNP5, MNP10, V.42, V.42bis |
Fax Class | Unidentified |
Data Bus | Serial |

CONNECTIONS | |||
Function | Label | Function | Label |
Telephone line in | CN1 | Microphone in | CN5 |
Telephone line out | CN2 | Speaker out | CN6 |
Serial port | CN3 | Microphone | MIC |
DC power in | CN4 | Power switch | SW1 |
DIAGNOSTIC LED(S) | |||
LED | Color | Status | Condition |
HS | Unidentified | On | Modem is operating at high speed |
HS | Unidentified | Off | Modem is operating at low speed |
AA | Unidentified | On | Auto-answer enabled |
AA | Unidentified | Off | Auto-answer disabled |
CD | Unidentified | On | Carrier signal detected |
CD | Unidentified | Off | Carrier signal not detected |
OH | Unidentified | On | Modem is off-hook |
OH | Unidentified | Off | Modem is on-hook |
RD | Unidentified | On | Modem is receiving data |
RD | Unidentified | Off | Modem is not receiving data |
SD | Unidentified | On | Modem is transmitting data |
SD | Unidentified | Off | Modem is not transmitting data |
TR | Unidentified | On | DTR signal is high |
TR | Unidentified | Off | DTR signal is low |
MR | Unidentified | On | Power is on |
MR | Unidentified | Off | Power is off |
SUPPORTED STANDARD COMMANDS |
Basic AT Commands |
+++, ‘comma’, A/ |
A, B, D, E, H, L, M, N, O, P, Q, T, V, W, X, Y, Z |
&C, &D, &F, &G, &K, &P, &Q, &R, &S, &T, &V, &W, &Y, &Z |
Extended AT Commands |
\A, \N, \K, \V |
%C, %E, %L, %Q |
Special AT Commands |
-K |
S-Registers |
S0, S1, S2, S3, S4, S5, S6, S7, S8, S9, S10, S11, S12, S14, S16, S18, S22, S24, S25, S26, S29 |
S30, S32, S33, S39, S46, S48, S82, S91, S92 |
Note: See MHI help file for complete information. |
UNIDENTIFIED COMMANDS | |
Command | Default |
S21 | 4 |
S23 | 55 |
S27 | 74 |
S28 | 0 |
S31 | 194 |
S37 | 0 |
S41 | 13 |
Proprietary AT Command Set
See POWERCOM AMERICA, INC. PM33V14I (ROCKWELL) for a full command summary.