PATTON ELECTRONICS COMPANY
1092A
Card Type | Modem |
Chip Set | Unidentified |
I/O Options | AC power connector, DTE/DCE serial port, network interface via RJ-45 connector |
Wiring Type | RJ-45 shielded twisted pair |
Maximum Data Rate | 128Kbps (synchronous), 38.4Kbps (asynchronous) |
Data Bus | External |

CONNECTIONS | |||||||
Function | Label | Function | Label | ||||
AC power connector | CN1 | DCE/DTE strap | CN4 | ||||
DTE/DCE port (QuikConnectä module) | CN2 | Power switch | SW3 | ||||
Network interface via RJ-45 connector | CN3 | ||||||
Note: | QuikConnectä serial interface module can be configured as a V.24/RS-232, V.35, RS422/530, or X.21 port. The DTE/DCE strap (X.21 only) is default configured for DCE interface. To change the interface to DTE, rotate the strap 180 degrees so the DTE arrows point to the X.21 port. | ||||||
USER CONFIGURABLE SETTINGS | ||
Setting | Label | Position |
í DSR on during local line loop | S1/3 | On |
DSR off during local line loop | S1/3 | Off |
í Modem responds to remote digital loopback requests from remote modem | S1/8 | On |
Modem ignores RDL requests from remote modem | S1/8 | Off |
í Factory configured - do not alter | S2/2 | Off |
í Modem ignores LAL requests from DTE | S2/3 | Off |
Modem responds to local analog loopback requests from DTE | S2/3 | On |
í 2-wire twisted pair operation enabled | S2/4 | On |
4-wire twisted pair operation enabled | S2/4 | Off |
í Factory configured - do not alter | S2/5 | Off |
í Modem responds to remote digital loopback requests from DTE | S2/6 | On |
Modem ignores RDL requests from DTE | S2/6 | Off |
ASYC/SYNC OPERATION | ||||
Setting | S1/4 | S1/5 | ||
í Factory configured - do not alter (async/sync operation enabled) | Off | Off | ||
DATA RATE | |||||||||||
Synchronous Data Rate | Asynchronous Data Rate | S1/1 | S1/2 | S2/1 | |||||||
19.2Kbps | Reserved | Off | Off | On | |||||||
32Kbps | Reserved | On | On | Off | |||||||
56Kbps | Reserved | Off | On | Off | |||||||
í 64Kbps | Reserved | On | Off | Off | |||||||
128Kbps | 0-38.4Kbps | Off | Off | Off | |||||||
TRANSMIT CLOCK SOURCE | ||
Source | S1/6 | S1/7 |
í Transmit clock generated internally | On | On |
Transmit clock derived from terminal interface | Off | On |
Transmit clock derived from receive line signal | On | Off |
Hardware reset | Off | Off |
CONTROL PORT DATA RATE | |||||
Setting | S2/7 | S2/8 | |||
í 9600bps | On | On | |||
19.2Kbps | Off | On | |||
LOOPBACK TEST SELECTOR | ||
Function | Label | Position |
Activates local analog loopback | SW4 | 1 |
Normal operation. Loopback not activated | SW4 | 2 |
Remote digital loopback initiated | SW4 | 3 |
TEST PATTERN GENERATOR | ||
Function | Label | Position |
511/E test pattern transmitted (intentional errors inserted) | SW5 | 1 |
Normal operation. Test pattern not activated | SW5 | 2 |
511 test pattern transmitted | SW5 | 3 |
DIAGNOSTIC LED(S) | |||
LED | Color | Status | Condition |
TD | Red | On | Data is being transmitted (low logic level, device idle) |
TD | Green | On | Data is being transmitted (high logic level) |
TD | None | Off | Data is not being transmitted |
RD | Red | On | Data is being received (low logic level, device idle) |
RD | Green | On | Data is being received (high logic level) |
RD | None | Off | Data is not being received |
CTS | Green | On | CTS signal is high |
CTS | Green | Off | CTS signal is low |
CD | Green | On | Carrier signal detected |
CD | Red | On | Carrier signal not detected |
DTR | Green | On | DTR signal is high |
DTR | Green | Off | DTR signal is low |
NS | Red | On | Local modem is not connected to remote modem |
NS | Red | Off | Local modem is connected to remote modem |
ER | Red | On | Bit error likely in received signal or error detected in 511 or 511/E test pattern |
ER | Red | Off | Error not detected |
TM | Red | On | Device has been placed in test mode by local or remote user |
TM | Red | Off | Device is not conducting a test |