PARADYNE CORPORATION
COMSPHERE 3825PLUS
Modem Type | Data (synchronous/asynchronous)/Fax |
Maximum Data Rate | 28.8Kbps |
Maximum Fax Rate | 14.4Kbps |
Data Bus | External |
Fax Class | Class I & II |
Data Modulation Protocol | AT&T V.32terbo Bell 103A/212A ITU-T V.21, V.22, V.22bis, V.32, V.32bis, V.34 |
Fax Modulation Protocol | ITU-T V.17, V.21CH2, V.27ter, V.29 |
Error Correction/Compression | MNP5, V.42, V.42bis |

CONNECTIONS | |||
Purpose | Location | Purpose | Location |
Line out | CN1 | DC power | CN4 |
Line in | CN2 | Power switch | SW1 |
RS-232/422 | CN3 | ||
DIAGNOSTIC LED(S) | |||
LED | Color | Status | Condition |
EC/SQ | Green | On | Error correction enabled |
EC/SQ | Green | Off | Error correction disabled |
EC/SQ | Green | Blinking, mostly on | Error correction activated and poor line signal errors detected |
EC/SQ | Green | Blinking, mostly off | Error correction not activated and poor line signal errors detected |
HS/RI | Green | On | Modem is operating at highest configured speed |
HS/RI | Green | Off | Modem is operating at less than highest configured speed |
HS/RI | Green | Blinking | Phone is ringing |
CD | Green | On | Carrier signal detected |
CD | Green | Off | Carrier signal not detected |
OH/APL | Green | On | Modem is off-hook |
OH/APL | Green | Off | Modem is on-hook |
OH/APL | Green | Blinking | Modem set for leased line |
RD | Green | On | Modem is receiving data |
RD | Green | Off | Modem is not receiving data |
SD | Green | On | Modem is transmitting data |
SD | Green | Off | Modem is not transmitting data |
TR | Green | On | DTR signal is high or modem is set to ignore signal |
TR | Green | Off | DTR signal is low |
MR/PWR | Green | Off | Power is off |
MR/PWR | Green | On | Power is on |
MR/PWR | Green | Blinking, slow | Download only mode |
MR/PWR | Green | Blinking, fast | Cloning mode |
MR/PWR | Green | Blinking | Power on in leased mode |
Proprietary AT Command Set
AT COMMAND RESPONSE | |
Type: | Register |
Format: | AT [cmds] S84=n [cmds] |
Example: | AT S84=0 &W <CR> |
Description: | Sets the response to AT commands. |
Command | Function |
í S84=0 | Normal operation |
S84=1 | Execute valid commands, suppress error codes. |
S84=2 | Ignore configuration commands, always return OK error code. |
AUTO BAUD | |
Type: | Register |
Format: | AT [cmds] S78=n [cmds] |
Example: | AT S78=0 &W <CR> |
Description: | Allows modem to connect at remote modem’s modulation. |
Command | Function |
í S78=0 | Auto baud enabled. |
S78=1 | Auto baud disabled. |
S78=2 | PBX operation. |
AUTO-RELIABLE FALLBACK CHARACTER | |
Type: | Register |
Format: | AT [cmds] %An [cmds] |
Example: | AT%A20 <CR> |
Default: | 19 |
Range: | 0-127 |
Unit: | ASCII |
Description: | Sets the character used as the auto-reliable fallback character. %A0 will disable this function. |
AUTO-RELIABLE TIME BUFFER CONFIGURATION | |
Type: | Configuration |
Format: | AT [cmds] \Cn [cmds] |
Example: | AT \C1 &W <CR> |
Description: | Controls the handling of incoming data during auto-reliable time period. |
Command | Function |
í \CO | Data is discarded. |
\C1 | Data is buffered. |
\C2 | Data is discarded, resets to \C1 on receipt of autoreliable fallback character. |
BREAK TYPE | |
Type: | Configuration |
Format: | AT [cmds] \Kn [cmds] |
Example: | AT \K5 &W <CR> |
Description: | Selects response to DTE break command. |
Command | Function |
\K0 | Send break, clear buffer, enter command mode. |
\K1 | Send break, clear buffer |
\K2 | Send break, send data, enter command mode. |
\K3 | Send break. send data, |
\K4 | Send data, send break, enter command mode. |
í \K5 | Send data, send break. |
\K6 | Disabled. |
BUSY OUT ON LOW DTR | |
Type: | Register |
Format: | AT [cmds] S69=n [cmds] |
Example: | AT S69=0 &W <CR> |
Description: | Modem goes off hook on low DTR (use only in PBX mode). |
Command | Function |
í S69=0 | Busy out disabled. |
S69=1 | Busy out enabled. |
CD SIGNAL | |
Type: | Configuration |
Format: | AT [cmds] &Cn [cmds] |
Example: | AT &C3 <CR> |
Description: | Configures the behavior of the carrier detect signal. |
Command | Function |
&C0 | CD forced high. |
í &C1 | CD normal. |
&C2 | CD forced high except during handshaking and disconnecting. |
&C3 | CD momentary interrupt on disconnect. |
&C4 | CD follows remote RTS signal. |
&C5 | CD Follows DTR signal. Forced low on disconnect. |
&C6 | CD forced low on retrain of over 10 sec. Forced high after no retrain for over 10 sec. |
CELLULAR ENHANCEMENTS | |
Type: | Register |
Format: | AT [cmds] S91=n [cmds] |
Example: | AT S91=0 &W <CR> |
Description: | Configures modem to enhanced cellular mode |
Command | Function |
í S91=0 | Disabled |
S91=1 | Enabled |
CLEAR ERROR BUFFER | |
Type: | Immediate |
Format: | AT [cmds] "F [cmds] |
Example: | AT "F &W <CR> |
Description: | Empties error buffer. |
COMPRESSION | |
Type: | Configuration |
Format: | AT %Cn |
Example: | AT I2 %C1 &B0 <CR> |
Description: | Selects data compression. |
Command | Function |
%C0 | Data compression disabled. |
í %C1 | Data compression enabled. |
CTS SIGNAL | |
Type: | Configuration |
Format: | AT [cmds] \Dn [cmds] |
Example: | AT \D0 <CR> |
Description: | Selects the function of the CTS signal. |
Command | Function |
í \D0 | CTS forced high. |
\D1 | CTS normal. |
\D2 | CTS interrupted for 2 seconds on disconnect. |
\D3 | CTS follows DTR. |
DISCONNECT BUFFER DELAY | |
Type: | Register |
Format: | AT [cmds] S39=n [cmds] |
Example: | AT S39=0 <CR> |
Default: | Unidentified |
Range: | 0-255 |
Unit: | 1 second |
Description: | Selects how long the modem will continue to transmit data in receive buffer after receipt of disconnect signal |
DISCONNECT BUFFER DELAY | |
Type: | Register |
Format: | AT [cmds] S49=n [cmds] |
Example: | AT S49=0 <CR> |
Default: | 10 |
Range: | 0-255 |
Unit: | 1 second |
Description: | Selects how long the modem will continue to transmit data in transmit buffer after receipt of disconnect signal |
DISCONNECT IMMEDIATELY | |
Type: | Configuration |
Format: | AT [cmds] S85=n [cmds] |
Example: | AT S85=0 &W <CR> |
Description: | Disconnect immediately on receipt of disconnect signal from DTE or diagnostic control panel. |
Command | Function |
í S85=0 | Disabled. |
S85=1 | Enabled. |
DISCONNECT INACTIVITY | |
Type: | Register |
Format: | AT [cmds] S80=n [cmds] |
Example: | AT S80=3 &W <CR> |
Description: | Sets the signal monitored by the inactivity timer (\T). |
Command | Function |
S80=0 | Transmit or receive. |
S80=1 | Transmit only. |
S80=2 | Receive only. |
í S80=3 | Transmit and receive. |
DISCONNECT ON LOSS OF CURRENT | |
Type: | Configuration |
Format: | AT [cmds] S65=n [cmds] |
Example: | AT S65=0 <CR> |
Description: | Causes the modem to disconnect if the telephone line’s current drops. |
Command | Function |
í S65=0 | Disconnect after 8ms if current is lost. |
S65=1 | Disconnect after 90ms if current is lost. |
S65=2 | Disabled |
FLOW CONTROL | |
Type: | Configuration |
Format: | AT [cmds] \Gn [cmds] |
Example: | AT \G1 &K3 <CR> |
Description: | Selects modem port flow control. |
Command | Function |
í \G0 | Flow control disabled. |
\G1 | Flow control enabled. |
FLOW CONTROL TYPE | |
Type: | Configuration |
Format: | AT [cmds] \Qn [cmds] |
Example: | AT \Q5 <CR> |
Description: | Sets type of flow control used by modem. |
Command | Function |
\Q0 | Flow control disabled. |
\Q1 | Bidirectional XON/XOFF flow control enabled. |
\Q2 | CTS flow control by DCE enabled. |
í \Q3 | Bidirectional CTS/RTS flow control enabled. |
\Q4 | XON/XOFF flow control by DCE enabled. |
\Q5 | XON/XOFF flow control by DTE enabled. |
\Q6 | RTS flow control by DTE enabled. |
INACTIVITY TIMER | |
Type: | Register |
Format: | AT [cmds] \Tn [cmds] |
Example: | AT\T20 <CR> |
Default: | 0 |
Range: | 0-255 |
Unit: | 1 minute |
Description: | Sets the length of time that the modem does not receive information before it disconnects. |
LAP-M FRAME SIZE | |
Type: | Configuration |
Format: | AT [cmds] \An [cmds] |
Example: | AT \A3 %C1 <CR> |
Description: | Sets the maximum frame size for V.42 and MNP connections. |
Command | Function |
\A0 | Maximum frame size is 64 |
\A1 | Maximum frame size is 128 |
\A2 | Maximum frame size is 192 |
í \A3 | Maximum frame size is 256 |
\A4 | Maximum frame size is 32 |
\A5 | Maximum frame size is 16 |
Note: Maximum V.42 frame size is 128. | |
LAP-M FRAME WINDOW | |
Type: | Register |
Format: | AT [cmds] S89=n [cmds] |
Example: | ATS89=6 <CR> |
Default: | 0 |
Range: | 1-9 |
Unit: | 1 frame (beginning with 1=6 frames, 0=auto adjust) |
Description: | Sets the number of frames used in V.42 and V.42bis transmissions |
LEASED LINE AUTO-RETRAIN | |
Type: | Register |
Format: | AT [cmds] S82=n [cmds] |
Example: | AT S82=0 &W <CR> |
Description: | Allows modem to retrain to compensate for bad line quality in V.32bis, V.32terbo or V.34 mode |
Command | Function |
í S82=0 | Retrain enabled. |
S82=1 | Retrain disabled. |
LEASED LINE DISCONNECT LEVEL | |
Type: | Register |
Format: | AT [cmds] S48=n [cmds] |
Example: | AT S48=0 &W <CR> |
Description: | Sets level carrier signal drops to before disconnect. |
Command | Function |
í S48=0 | Disconnect at -43dBm |
S48=1 | Disconnect at -26dBm |
LEASED LINE SPEED | |
Type: | Register |
Format: | AT [cmds] S44=n [cmds] |
Example: | ATS44=6 <CR> |
Default: | 27 |
Description: | Sets maximum leased line speed |
Command | Function |
S44=1 | 14.4Kbps V.32bis |
S44=2 | 12.0Kbps V.32bis |
S44=3 | 9600bps V.32bis, V.32 |
S44=4 | 7200bps V.32bis |
S44=5 | 4800bps V.32bis, V.32 |
S44=6 | 2400bps V.22bis |
S44=18 | 19.2Kbps V.32terbo |
S44=19 | 16.8Kbps V.32terbo |
S44=25 | 33.6Kbps AT&T V.34 |
S44=26 | 31.2Kbps AT&T V.34 |
í S44=27 | 28.8Kbps V.34 |
S44=28 | 26.4Kbps V.34 |
S44=29 | 24.0Kbps V.34 |
S44=30 | 21.6Kbps V.34 |
S44=31 | 19.2Kbps V.34 |
S44=32 | 16.8Kbps V.34 |
S44=33 | 14.4Kbps V.34 |
S44=34 | 12.0Kbps V.34 |
S44=35 | 9600bps V.34 |
S44=36 | 7200bps V.34 |
S44=37 | 4800bps V.34 |
S44=38 | 2400bps V.34 |
LEASED LINE TRANSMISSION LEVEL | |
Type: | Register |
Format: | AT [cmds] S45=n [cmds] |
Example: | AT S45=15 <CR> |
Default: | 0 |
Range: | 0 - 15 |
Unit: | 1 dBm |
Description: | Sets the signal level for transmission when in leased line mode. |
LINE TYPE | |
Type: | Configuration |
Format: | AT [cmds] &Ln [cmds] |
Example: | AT &L0 H1 DT555-1212 <CR> |
Description: | Selects line type. |
Command | Function |
í &L0 | Switched line. |
&L1 | 2-wire originate mode leased line. |
&L2 | 2-wire answer mode leased line. |
LOCK SERIAL PORT | |
Type: | Configuration |
Format: | AT [cmds] S90=n [cmds] |
Example: | AT S90=0 <CR> |
Description: | Sets operation of serial port speed. |
Command | Function |
í S90=0 | Disabled. |
S90=1 | Serial speed follows connect speed. |
NETWORK POSITION IDENTIFICATION | |
Type: | Register |
Format: | AT [cmds] S74=n [cmds] |
Example: | AT S74=0 &W <CR> |
Description: | Identifies modem as either tributary or control |
Command | Function |
í S74=0 | Identify as tributary |
í S74=1 | Identify as control |
PASSWORD REMOTE ACCESS | |
Type: | Register |
Format: | AT [cmds] S56=n [cmds] |
Example: | ATS56=6 <CR> |
Default: | None |
Range: | 00-99 |
Unit: | Password digits |
Description: | Allows entry of the first two digits of remote access password. |
PASSWORD REMOTE ACCESS | |
Type: | Register |
Format: | AT [cmds] S57=n [cmds] |
Example: | ATS57=6 <CR> |
Default: | None |
Range: | 00-99 |
Unit: | Password digits |
Description: | Allows entry of the second two digits of remote access password. |
PASSWORD REMOTE ACCESS | |
Type: | Register |
Format: | AT [cmds] S58=n [cmds] |
Example: | ATS58=6 <CR> |
Default: | None |
Range: | 00-99 |
Unit: | Password digits |
Description: | Allows entry of the third two digits of remote access password. |
PASSWORD REMOTE ACCESS | |
Type: | Register |
Format: | AT [cmds] S59=n [cmds] |
Example: | ATS59=6 <CR> |
Default: | None |
Range: | 00-99 |
Unit: | Password digits |
Description: | Allows entry of the fourth two digits of remote access password. |
PROTOCOL/SPEED | |
Type: | Immediate |
Format: | AT [cmds] %Bn [cmds] |
Example: | AT %B14400 <CR> |
Description: | Selects the current DCE speed. |
Command | Function |
%B300 | Select V.21 or Bell103 at 300bps speed. |
%B1200 | Select V.22,V.23 or Bell 212A at 1200bps speed. |
%B2400 | Select V.34 at 2400bps speed. |
%B4800 | Select V.34 at 4800bps speed. |
%B7200 | Select V.34 at 7200bps speed. |
%B9600 | Select V.34 at 9600bps uncoded speed. |
%B12000 | Select V.34 at 12Kbps speed. |
%B14400 | Select V.34 at 14.4Kbps speed. |
%B16800 | Select V.34 at 16.8Kbps speed. |
%B19200 | Select V.34 at 19.2Kbps speed. |
%B21600 | Select V.34 at 21.6Kbps speed. |
%B24000 | Select V.34 at 24Kbps speed. |
%B26400 | Select V.34 at 26.4Kbps speed. |
í %B28800 | Select V.34 at 28.8Kbps speed. |
%BL31200 | Select V.34 proprietary at 31.2Kbps speed. |
%BL33600 | Select V.34 proprietary at 33.6Kbps speed. |
%BL2400 | Select V.22bis at 2400Kbps speed. |
%BL4800 | Select V.32bis/V.32 at 4800Kbps speed. |
%BL7200 | Select V.32bis at 7200Kbps speed. |
%BL9600 | Select V.32bis/V.32 at 9600Kbps speed. |
%BL12000 | Select V.32bis at 12Kbps speed. |
%BL14400 | Select V.32bis at 14.4Kbps speed. |
%BL16800 | Select V.32terbo at 16.8Kbps speed. |
%BL19200 | Select V.32terbo at 19.2Kbps speed. |
REMOTE CLONE | |
Type: | Configuration |
Format: | AT [cmds] &&P1 [cmds] |
Example: | AT &&P1 &W <CR> |
Description: | In online command mode, copies firmware to remote 3825Plus modem |
REMOTE CONFIGURATION | |
Type: | Configuration |
Format: | AT [cmds] S55=n [cmds] |
Example: | AT S55=0 &W <CR> |
Description: | Allows remote configuration by 3800 series modem. |
Command | Function |
í S55=0 | Remote configuration enabled. |
S55=1 | Remote configuration disabled. |
REPORT INFORMATION | |
Type: | Immediate |
Format: | AT [cmds] In [cmds] |
Example: | AT I1 O <CR> |
Description: | Displays modem properties. |
Command | Function |
I0 | Reports product code. |
I1 | Reports firmware 3 digit version number. |
I2 | Performs EPROM check |
I3 | Reports serial number |
I4 | Reports model number |
I5 | Reports hardware part number |
I6 | Reports software part number |
I9 | Reports firmware 3 digit version number. |
I11 | Reports RAM checksum result. |
I17 | Reports last eight critical errors from last to first |
I19 | Reports complete firmware revision number |
RJ11 CELLULAR ADAPT | |
Type: | Register |
Format: | AT [cmds] S93=n [cmds] |
Example: | AT S93=0 &W <CR> |
Description: | Adds support for RJ11 connection during cellular operation |
Command | Function |
í S93=0 | Disabled. |
S93=1 | Enabled. |
SECURITY CHANGE ADMINISTRATION PASSWORD | |
Type: | Configuration |
Format: | AT [cmds] %SA=nnnnnnnn [cmds] |
Example: | AT %SA=22233344 &W <CR> |
Description: | Changes administration password. |
SECURITY CHANGE DTE PASSWORD | |
Type: | Configuration |
Format: | AT [cmds] %SBi=nnnnnnnn [cmds] |
Example: | AT %SBi=22233344 &W <CR> |
Description: | Changes the DTE type password in index i. |
SECURITY CHANGE VF PLUS DTE PASSWORD | |
Type: | Configuration |
Format: | AT [cmds] %SBi=nnnnnnnn [cmds] |
Example: | AT %SBi=22233344 &W <CR> |
Description: | Changes the VF plus DTE type password in index i. |
SECURITY CHANGE VF PASSWORD | |
Type: | Configuration |
Format: | AT [cmds] %SVi=nnnnnnnn [cmds] |
Example: | AT %SVi=22233344 &W <CR> |
Description: | Changes the VF type password in index i. |
SECURITY DISPLAY PASSWORD | |
Type: | Immediate |
Format: | AT [cmds] %SPi [cmds] |
Example: | AT %SPi &W <CR> |
Description: | Displays the VF or DTE type password in index i. |
SECURITY DELETE PASSWORD | |
Type: | Configuration |
Format: | AT [cmds] %SPi= [cmds] |
Example: | AT %SPi= &W <CR> |
Description: | Delete the VF or DTE type password in index i. |
SECURITY ENTER ADMINISTRATION PASSWORD | |
Type: | Configuration |
Format: | AT [cmds] %SAnnnnnnnn [cmds] |
Example: | AT %SA22233344 &W <CR> |
Description: | Sets modem to allow security configuration and password changes. |
SECURITY RESET | |
Type: | Configuration |
Format: | AT [cmds] %SR [cmds] |
Example: | AT %SR &W <CR> |
Description: | Resets administration password and empties password table |
STORED PROFILE | |
Type: | Register |
Format: | AT [cmds] S88=n [cmds] |
Example: | AT S88=0 &W <CR> |
Description: | Loads stored profile on disconnect. |
Command | Function |
í S88=0 | Disabled. |
S88=231 | Disabled. |
S88=1 | Enabled. |
S88=232 | Enabled. |
SWITCHED LINE SPEED | |
Type: | Register |
Format: | AT [cmds] S41=n [cmds] |
Example: | ATS41=6 <CR> |
Default: | 20 |
Description: | Sets maximum line speed |
Command | Function |
S41=1 | 14.4Kbps V.32bis |
S41=2 | 12.0Kbps V.32bis |
S41=3 | 9600bps V.32bis, V.32 |
S41=4 | 7200bps V.32bis |
S41=5 | 4800bps V.32bis, V.32 |
S41=6 | 2400bps V.22bis |
S41=7 | 1200bps V.22 |
S41=8 | 1200bps 212A |
S41=10 | 0-300bps V21 |
S41=11 | 0-300bps 103J |
S41=20 | 19.2Kbps V.32terbo |
S41=21 | 16.8Kbps V.32terbo |
S41=27 | 33.6Kbps AT&T V.34 |
S41=28 | 31.2Kbps AT&T V.34 |
í S41=29 | 28.8Kbps V.34 |
S41=30 | 26.4Kbps V.34 |
S41=31 | 24.0Kbps V.34 |
S41=32 | 21.6Kbps V.34 |
S41=33 | 19.2Kbps V.34 |
S41=34 | 16.8Kbps V.34 |
S41=35 | 14.4Kbps V.34 |
S41=36 | 12.0Kbps V.34 |
S41=37 | 9600bps V.34 |
S41=38 | 7200bps V.34 |
S41=39 | 4800bps V.34 |
S41=40 | 2400bps V.34 |
TRANSMISSION LEVEL | |
Type: | Configuration |
Format: | AT [cmds] &In [cmds] |
Example: | AT &I26 &W <CR> |
Default: | Unidentified |
Range: | 0-32, 99, 100 |
Unit: | -1 dBm |
Description: | Sets the signal level for transmission |
Note: 0-8 invalid in North America. Set to 99 for autoadjust ETC1.0 specification. Set to 100 for autoadjust ETC1.1 specification | |
TRANSMISSION LEVEL | |
Type: | Configuration |
Format: | AT [cmds] &J0 [cmds] |
Example: | AT &J0 &W <CR> |
Description: | Sets -9 dBm permissive mode |
V.25bis CODE SET | |
Type: | Configuration |
Format: | AT [cmds] S62=n [cmds] |
Example: | AT S62=0 &W <CR> |
Description: | Sets coding type used in V.25bis mode. |
Command | Function |
í S62=0 | ASCII |
S62=1 | EBCDIC |
V.25bis IDLE CHARACTER | |
Type: | Configuration |
Format: | AT [cmds] S63=n [cmds] |
Example: | AT S63=0 &W <CR> |
Description: | Sets V.25 idle fill type |
Command | Function |
í S63=0 | Fill character is mark. |
S63=1 | Fill character is flag. |
V.25bis NEW LINE CHARACTER | |
Type: | Configuration |
Format: | AT [cmds] S64=n [cmds] |
Example: | AT S64=0 &W <CR> |
Description: | Sets V.25 new line character. |
Command | Function |
í S64=0 | Carriage return and line feed. |
S64=1 | Carriage return. |
S64=2 | Line feed. |
V.32bis AUTO-RETRAIN | |
Type: | Register |
Format: | AT [cmds] S76=n [cmds] |
Example: | AT S76=0 &W <CR> |
Description: | Selects action the modem will take during bad line quality on 32bis connection. |
Command | Function |
í S76=0 | Auto retrain enabled. |
S76=1 | Auto retrain disabled. |
S76=2 | Auto retrain started at 4800bps for V.32bis operation. |
S76=3 | Auto retrain started at 9600bps for V.32bis operation. |
V.32bis TRAIN | |
Type: | Register |
Format: | AT [cmds] S43=n [cmds] |
Example: | AT S43=0 &W <CR> |
Description: | Sets train length for V.34, V.32terbo, V.32bis and V32. |
Command | Function |
í S43=0 | Long |
S43=1 | Short |
V.34 SPLIT BAUD MODE | |
Type: | Configuration |
Format: | AT [cmds] S14=n [cmds] |
Example: | AT S14=0 <CR> |
Description: | Controls V.34 split baud mode. |
Command | Function |
í S14=0 | V.34 split baud mode enabled. |
S14=1 | V.34 split baud mode disabled. |
V.42bis COMPRESSION CONTROL | |
Type: | Configuration |
Format: | AT [cmds] "Hn [cmds] |
Example: | AT "H3 &W <CR> |
Description: | Controls V.42bis data compression |
Command | Function |
"H0 | V.42bis disabled. |
"H1 | V.42bis when transmitting enabled. |
"H2 | V.42bis when receiving enabled. |
í "H3 | V.42bis when transmitting/receiving enabled. |
XON/XOFF PASS-THROUGH | |
Type: | Configuration |
Format: | AT [cmds] \Xn [cmds] |
Example: | AT \X7 O <CR> |
Description: | Selects whether XON/XOFF signals are sent to remote modem. |
Command | Function |
í \X0 | XON/XOFF signals trapped by local modem. |
\X1 | XON/XOFF passed through local modem. |
DTR ALARM | |
Type: | Register |
Format: | AT [cmds] S77=n [cmds] |
Example: | AT S77=0 &W <CR> |
Description: | Sends alarm to proprietary Series Management Controller if DTR low for 10 seconds. |
Command | Function |
í S77=0 | Alarm disabled. |
S77=1 | Alarm enabled. |
CALLBACK SECURITY | |
Type: | Register |
Format: | AT [cmds] S67=n [cmds] |
Example: | AT S67=0 &W <CR> |
Description: | Enables callback security option |
Command | Function |
í S67=0 | Disabled |
S67=1 | Enabled |
ANSWER SECURITY | |
Type: | Register |
Format: | AT [cmds] S68=n [cmds] |
Example: | AT S68=0 &W <CR> |
Description: | Selects what type of answer security is used. |
Command | Function |
S68=0 | Answer security disabled |
S68=1 | DTE answer security enabled. |
S68=2 | VF and DTE answer security enabled |
S68=3 | VF with DTE answer security enabled |
ORIGINATE SECURITY | |
Type: | Register |
Format: | AT [cmds] S70=n [cmds] |
Example: | AT S70=0 &W <CR> |
Description: | Enables originate security option |
Command | Function |
í S70=0 | Originate security disabled |
S70=1 | Originate security enabled |
VF PROMPT TYPE | |
Type: | Register |
Format: | AT [cmds] S95=n [cmds] |
Example: | AT S95=0 &W <CR> |
Description: | Selects the type of VF password prompt sent to remote dialer. |
Command | Function |
í S95=0 | Second dial tone |
S95=1 | Quiet answer |
Note: Also selects which dial modifier (@ or W) must precede password | |
PASSWORD ATTTEMPT LIMIT | |
Type: | Register |
Format: | AT [cmds] S96=n [cmds] |
Example: | AT S96=0 &W <CR> |
Description: | Sets number of DTE password attempts before disconnect. |
Command | Function |
í S96=0 | 1 attempt |
S96=1 | 2 attempts |
S96=2 | 3 attempts |
S96=3 | 4 attempts |
S96=4 | 5 attempts |
PASSWORD DTE TERMINATION CHARACTER | |
Type: | Register |
Format: | AT [cmds] S97=n [cmds] |
Example: | ATS97=13 <CR> |
Default: | 13 |
Range: | 1-127 |
Unit: | ASCII |
Description: | Sets Character used to indicate end of password or callback directory/number |
PASSWORD BACKSPACE CHARACTER | |
Type: | Register |
Format: | AT [cmds] S98=n [cmds] |
Example: | ATS98=8 <CR> |
Default: | 8 |
Range: | 0-127 |
Unit: | ASCII |
Description: | Sets Character used backspace when entering password or callback directory/number |