OLICOM, INC.
OC-7111
Card Type | Fax, Modem (asynchronous) |
Chip Set | Unidentified |
Maximum Data Rate | 28.8Kbps |
Maximum Fax Rate | 14.4Kbps |
Data Bus | PCMCIA Type II |
Fax Class | Class I & II |
Data Modulation Protocol | Bell 103/212A ITU-T V.21, V.22, V.22bis, V.23, V.32, V.32bis, V.34 Rockwell V.FC |
Fax Modulation Protocol | ITU-T V.17, V.21CH2, V.27ter, V.29 |
Error Correction/Compression | MNP5, MNP10, V.42, V.42bis |
V1942
MISCELLANEOUS TECHNICAL NOTES |
Note: Due to country specific parameters, S-register settings are unidentified. |
Proprietary AT Command Set
AUTOSYNC™ | ||
Format | AT [cmds] S19=n [cmds] | |
Default: | Unidentified | |
Range: | 0-30 | |
Unit: | Bit-mapped | |
Description: | Sets options for Hayes AutoSync™ functions. | |
Bit | Value | Function |
0 | 0 | Not used. |
1 | 0 1 | BSC enabled. HDLC enabled. |
2 | 0 1 | HDLC address detection disabled. HDLC address detection enabled. |
3 | 0 1 | NRZI bit encoding enabled. NRZ2 bit encoding enabled. |
4 | 0 1 | Mark idle enabled. Flag or sync idle enabled. |
AUTOSYNC HDLC ADDRESS | |
Type: | Register |
Format: | AT [cmds] S20=n [cmds] |
Default: | Unidentified |
Range: | 0-255 |
Unit: | Unidentified |
Description: | Sets the HDLC address/BSC character |
AUTO-RETRAIN - AUTO-FALLBACK/FALL-FORWARD | |
Type: | Configuration |
Format: | AT [cmds] %En [cmds] |
Description: | Controls auto-retrain mode and fallback/fall-forward |
Command | Function |
í %E0 | Auto-retrain disabled |
%E1 | Auto-retrain enabled |
%E2 | Auto-fallback/fall-forward enabled |
%E3 | Auto-retrain enabled with fast hang-up |
BIT MAPPED REGISTERS | |
Register | Default |
S14 | Unidentified |
S21 | Unidentified |
S22 | Unidentified |
S23 | Unidentified |
S27 | Unidentified |
S28 | Unidentified |
S31 | Unidentified |
S40 | Unidentified |
S41 | Unidentified |
S201 | Unidentified |
BREAK SEND | |
Type: | Configuration |
Format: | AT [cmds] \Bn [cmds] |
Default: | 3 |
Range: | 1-9 |
Unit: | .1 second |
Description: | Sends break to modem |
BREAK TYPE | ||||
Type: | Configuration | |||
Format: | AT [cmds] \Kn [cmds] | |||
Description: | Configures action of break signal | |||
Command | Break from DTE | Modem receives \B | Break received from remote modem | |
\K0 | Online command mode enabled, send no break to remote modem | Break sent to remote modem and buffered cleared | Buffers cleared, break sent to DTE | |
\K1 | Break sent to remote modem and buffered cleared | Break sent to remote modem and buffered cleared | Buffers cleared, break sent to DTE | |
\K2 | Online command mode enabled, send no break to remote modem | Send break to remote modem immediately | Break sent immediately to DTE | |
\K3 | Send break to remote modem immediately | Send break to remote modem immediately | Break sent immediately to DTE | |
\K4 | Online command mode enabled, send no break to remote modem | Send break with transmitted data | Break sent with received data to the DTE | |
í \K5 | Send break with transmitted data | Send break with transmitted data | Break sent with received data to the DTE | |
COUNTRY CODE | |
Type: | Configuration |
Format: | AT [cmds] *NCnn [cmds] |
Description: | Select a country code from NVRAM (nn=00-08) |
DIAL | |
Type: | Immediate |
Format: | AT [cmds] D<#> [cmds] |
Description: | Dials telephone number according to any modifiers included in the string |
Note: | Any combination of modifiers can be used to produce the desired dial functions in sequence. |
Command | Function |
DJ | Link will be negotiated at 1200bps for current call only |
DK | Power level adjustment enabled for current call only |
DL | Re-dial last number |
DP | Pulse dialing enabled |
DT | Tone dialing enabled/Pulse dialing disabled |
DR | Accepted but not used. |
DS=n | Dial stored telephone number n |
D! | Flash function initiated. Modem commanded to go off-hook for specified time before returning on-hook. |
DW | Dialing resumed following dial tone detection |
D@ | Wait for Quiet Answer function enabled. Modem waits until a "quiet answer," a ring-back signal followed by silence up to the time specified in S7, is received prior to executing the rest of the dial string. |
D, | Dialing paused for amount of time specified in S8 register |
D; | Modem returned to command state after dialing. The semicolon can only be placed at the end of the dial command. |
D^ | Calling tone enabled/disabled for current dialing attempt |
DIALING CODE | ||
Type: | Configuration | |
Format: | AT [cmds] *Zn [cmds] | |
Description: | Select the dial code for pulse dialing | |
Command | Function | |
í *Z0 | Use dial code 0 | |
*Z1 | Use dial code 1 | |
DELAYED NUMBERS | |
Type: | Immediate |
Format: | AT [cmds] *B [cmds] |
Description: | Displays delayed numbers list |
DELAYED NUMBERS | |
Type: | Immediate |
Format: | AT [cmds] *D [cmds] |
Description: | Displays delayed numbers list |
COMPRESSION | |
Type: | Configuration |
Format: | AT [cmds] %Cn [cmds] |
Description: | Selects data compression |
Command | Function |
%C0 | Data compression disabled |
%C1 | MNP5 enabled |
%C2 | V.42bis enabled |
í %C3 | MNP5 and V.42bis enabled |
CONNECT MODE | |
Type: | Configuration |
Format: | AT [cmds] \Nn [cmds] |
Description: | Controls the type of connection the modem will operate in |
Command | Function |
\N0 | Normal mode enabled |
\N1 | Direct mode enabled |
\N2 | MNP reliable mode enabled |
í \N3 | Auto-reliable mode enabled |
\N4 | V.42 reliable mode enabled |
\N5 | MNP auto-reliable mode enabled |
FLASH DIAL MODIFIER TIME | |
Type: | Register |
Format | AT [cmds] S29=n [cmds] |
Default: | 0 |
Range: | 0-255 |
Unit: | Unidentified |
Description: | Time the modem will go on-hook upon receiving the ! dial modifier in dial string. |
FLOW CONTROL | |
Type: | Configuration |
Format: | AT [cmds] \Gn [cmds] |
Description: | Selects modem port flow control |
Command | Function |
í \G0 | Flow control disabled |
\G1 | Flow control enabled |
FLOW CONTROL CHARACTER - XOFF | |
Type: | Register |
Format: | AT [cmds] S33=n [cmds] |
Default: | 19 |
Range: | 0-255 |
Unit: | ASCII |
Description: | Sets the character used to represent XOFF |
FLOW CONTROL CHARACTER - XON | |
Type: | Register |
Format: | AT [cmds] S32=n [cmds] |
Default: | 17 |
Range: | 0-255 |
Unit: | ASCII |
Description: | Sets the character used to represent XON |
LINE SIGNAL LEVEL | |
Type: | Immediate |
Format: | AT [cmds] %L [cmds] |
Description: | Returns a value which indicates the received line signal level |
LINE SIGNAL QUALITY | |
Type: | Immediate |
Format: | AT [cmds] %Q [cmds] |
Description: | Returns a value which indicates line signal quality |
LOCK SERIAL PORT | |
Type: | Configuration |
Format: | AT [cmds] \Jn [cmds] |
Description: | Sets operation of serial port speed |
Command | Function |
í \J0 | Serial speed locked |
\J1 | Serial speed follows connect speed |
MAXIMUM BLOCK SIZE FOR TRANSMISSION | |
Type: | Configuration |
Format: | AT [cmds] \An [cmds] |
Description: | Sets the maximum transmittable block size |
Command | Function |
\A0 | MNP block size is 64 characters |
í \A1 | MNP block size is 128 characters |
\A2 | MNP block size is 192 characters |
\A3 | MNP block size is 256 characters |
MODULATION SELECTION DISPLAY | ||
Type: | Immediate | |
Format: | AT [cmds] +MS? [cmds] | |
Description: | Displays modulation, automode, minimum rate and maximum rate settings | |
Command | Function | |
+MS=? | Displays supported mode selection | |
MODULATION SELECTION | |
Type: | Configuration |
Format: | AT [cmds] +MS=x,y,z,a [cmds] |
Description: | Sets options for active protocol; the transfer rates specified by z and a must be valid for the protocol selected. |
Command | Function |
x=0 | V.21 |
x=1 | V.22 |
x=2 | V.22bis |
x=3 | V.23 |
x=9 | V.32 |
x =10 | V.32bis |
x=11 | V.34 |
x =64 | Bell 103 |
x =69 | Bell 212A |
x =74 | V.FC |
y =0 | Automode disabled |
y =1 | Auto-detect highest speed enabled |
z, a=300 | Set minimum or maximum transfer rate at 300bps, respectively. |
z, a =1200 | Set minimum or maximum transfer rate at 1200bps, respectively. |
z, a =2400 | Set minimum or maximum transfer rate at 2400bps, respectively. |
z, a =4800 | Set minimum or maximum transfer rate at 4800bps, respectively. |
z, a =7200 | Set minimum or maximum transfer rate at 7200bps, respectively. |
z, a =9600 | Set minimum or maximum transfer rate at 9600bps, respectively. |
z, a =12000 | Set minimum or maximum transfer rate at 12000bps, respectively. |
z, a =14400 | Set minimum or maximum transfer rate at 14400bps, respectively. |
z, a =16800 | Set minimum or maximum transfer rate at 16800bps, respectively. |
z, a =19200 | Set minimum or maximum transfer rate at 19200bps, respectively. |
z, a =21600 | Set minimum or maximum transfer rate at 21600bps, respectively. |
z, a =24000 | Set minimum or maximum transfer rate at 24000bps, respectively. |
z, a =26400 | Set minimum or maximum transfer rate at 26400bps, respectively. |
z, a =28800 | Set minimum or maximum transfer rate at 28800bps, respectively. |
MNP - EXTENDED SERVICES | |
Type: | Configuration |
Format: | AT [cmds] -Kn [cmds] |
Description: | Selects MNP extended services |
Command | Function |
í -K0 | MNP extended services disabled |
-K1 | MNP extended services enabled |
MNP - STREAM/BLOCK MODE | |
Type: | Configuration |
Format: | AT [cmds] \Ln [cmds] |
Description: | Selects the transfer mode for MNP link |
Command | Function |
í \L0 | Stream mode for MNP enabled |
\L1 | Block mode for MNP enabled |
MNP10 - FALLBACK | |
Type: | Configuration |
Format: | AT [cmds] -Qn [cmds] |
Description: | Allows MNP10 to fall back to speeds slower than 4800bps |
Command | Function |
-Q0 | MNP10 at 2400 and 1200bps enabled |
-Q1 | MNP10 at 2400 and 1200bps disabled |
MNP10 - LINK NEGOTIATION | |
Type: | Configuration |
Format: | AT [cmds] *Hn [cmds] |
Description: | Sets the speed at which MNP10 link negotiation will occur |
Command | Function |
*H0 | Link will be negotiated at highest possible speed |
*H1 | Link will be negotiated at 1200bps |
*H2 | Link will be negotiated at 4800bps |
MNP10 - POWER LEVEL ADJUST | |
Type: | Configuration |
Format: | AT [cmds] )Mn [cmds] |
Description: | Controls automatic transmit power level adjustment during MNP 10 link negotiation |
Command | Function |
í )M0 | Power level adjustment disabled |
)M1 | Power level adjustment enabled |
REPORT INFORMATION | |
Type: | Immediate |
Format: | AT [cmds] In [cmds] |
Description: | Displays information requested |
Command | Function |
I0 | Reports product code |
I1 | Reports ROM checksum |
I2 | Calculates and reports ROM checksum |
I3 | Reports firmware level |
I5 | Reports country code |
SLEEP TIMER | |
Type: | Register |
Format | AT [cmds] S24=n [cmds] |
Default: | 0 |
Range: | Unidentified |
Unit: | Unidentified |
Description: | Maximum duration of DTE and DCE inactivity allowed prior to initiating low-power sleep mode. |
STORED NUMBERS | |
Type: | Immediate |
Format: | AT [cmds] \Fn [cmds] |
Description: | Displays phone number directory |
TEST MODES | ||
Type: | Register | |
Format: | AT [cmds] S16=n [cmds] | |
Default: | Unidentified | |
Range: | 0-125 | |
Unit: | Bit-mapped | |
Description: | Controls loopback tests, analog, digital, remote digital, and self tests. | |
Bit | Value | Function |
0 | 0 1 | Local analog loopback not in progress Local analog loopback in progress |
1 | 0 | Not used |
2 | 0 1 | Local digital loopback not in progress Local digital loopback in progress |
3 | 0 1 | Modem not in remote digital loopback Remote digital loopback in progress |
4 | 0 1 | Remote digital loopback not requested Remote digital loopback requested |
5 | 0 1 | Remote digital loopback w/ self-test not in progress Remote digital loopback w/ self-test in progress |
6 | 0 1 | Local analog loopback w/ self-test not in progress Local analog loopback w/ self-test in progress |
TRANSMISSION LEVEL - CELLULAR | |
Type: | Configuration |
Format: | AT [cmds] @Mn [cmds] |
Default: | Unidentified |
Range: | 0-31 |
Unit: | -1dBm |
Description: | Sets the signal level for transmission while in cellular mode |
TRANSMISSION LEVEL - FAX | |
Type: | Register |
Format: | AT [cmds] S92=n [cmds] |
Default: | Unidentified |
Range: | 0-15 |
Unit: | -1 dBm |
Description: | Sets the signal level for transmission while in fax mode |
TRANSMISSION LEVEL - PSTN | |
Type | Register |
Format | AT [cmds] S91=n [cmds] |
Default | Unidentified |
Range | 0-15 |
Unit | -1 dBm |
Description | Sets the signal level for transmission over switched phone lines |
V.32 - COMPROMISE EQUALIZER | |
Type: | Configuration |
Format: | AT [cmds] :En [cmds] |
Description: | Controls V.32 compromise equalizer |
Command | Function |
:E0 | Equalizer disabled |
í :E1 | Equalizer enabled |