MULTI-TECH SYSTEMS, INC.
MT5634ZLX
Card Type | Modem |
Chip Set | Unidentified |
Maximum Modem Rate | 56Kbps |
Maximum Fax Rate | 14.4Kbps |
Data Modulation Protocol | Bell 103/212A ITU-T V.22, V.22bis, V.32ter, V.32bis, V.34, K56flex |
Fax Modulation Protocol | ITU-T V.17, V.29 |
Error Correction/Compression | MNP5, V.42, V.42bis |
Fax Class | I & II |
Data Bus | PCMCIA |
MULTI-TECH-SYSTEMS-INC-Modem-MT5634ZLX
SUPPORTED COMMAND SET |
Basic AT Commands |
AT, ‘+++’, A/ |
A, E, H, M, P, Q, T, V, W, X, Z |
&C, &F, &G, &P, &R, &V, &W, &Y, &Z |
Extended AT Commands |
\A, \G, \J, \K, \V, \X |
S Registers |
S0, S1, S2, S3, S4, S5, S6, S7, S8, S9, S10, S11, S12, S18, S25, S30 |
Note: See MHI Help File for full command documentation. |
Proprietary AT Command Set
AUTO-MODE DETECTION | |
Type: | Configuration |
Format: | AT [cmds] Nn [cmds] |
Description: | Selects various options for the automatic detection and negotiation of protocols during the handshake process if the modem is communicating with a remote modem of dissimilar speed. |
Command | Function |
N0 | Auto-mode detection disabled. Handshake begins at line speed designated by the S37 register. If S37=0 handshake follows interface speed |
í N1 | Auto-mode detection enabled. Handshake begins at line speed designated by the S37 register. If S37=0 handshake at highest possible speed with fallback to lower speed if necessary |
COMMUNICATION PROTOCOLS | |
Type: | Configuration |
Format: | AT [cmds] Bn [cmds] |
Description: | Selects the communication protocol for data calls |
Note: The B command allows the simultaneous selection of more than one suffix, enabling multiple protocols. | |
Command | Protocol |
B0 | ITU-T V.22 at 1200bps or V.21 at 300bps |
í B1 | Bell 212A at 1200bps/Bell 103 at 300bps |
B2 | ITU-T V.23 at 75/1200bps originate; 1200/75bps answer |
B3 | ITU-T V.23 at 1200/75bps answer; 75/1200bps originate |
DATA SET READY (DSR) | |
Type: | Configuration |
Format: | AT [cmds] &Sn [cmds] |
Description: | Selects DSR options |
Command | Function |
í &S0 | DSR forced high |
&S1 | DSR high only while modem is connected |
DATA TERMINAL READY (DTR) | |
Type: | Configuration |
Format: | AT [cmds] &Dn [cmds] |
Description: | Selects modem response to DTR |
Command | Function |
&D0 | Modem does not respond to DTR |
&D1 | Modem goes to command mode on DTR toggle |
í &D2 | Modem goes to command mode and disconnects (hangs up) on DTR toggle; Auto-Answer is disabled on low DTR. |
&D3 | Modem is initialized on DTR toggle |
DIAL | |
Type: | Immediate |
Format: | AT [cmds] D<#> [cmds] |
Description: | Dials telephone number according to any modifiers included in the string |
Note: | Any combination of modifiers can be used to produce the desired dial functions in sequence. |
Command | Function |
DP | Pulse dialing enabled |
DR | Answer mode enabled; originate mode disabled following handshake initiation. |
DSn | Dial stored telephone number n |
DT | Tone dialing enabled/Pulse dialing disabled |
DW | Dialing resumed following dial tone detection |
D, | Dialing paused for amount of time specified in S8 register |
D! | Flash function initiated. Modem commanded to go off-hook for specified time before returning on-hook. |
D@ | Wait for quiet Answer function enabled. Modem waits until a "quiet answer," a ring-back signal followed by silence up to the time specified in S7, is received prior to executing the rest of the dial string. |
D; | Modem returned to idle state after dialing. The semicolon can only be placed at the end of the dial command. |
FLOW CONTROL | |
Type: | Configuration |
Format: | AT [cmds] &Kn [cmds] |
Description: | Enables flow control options |
Command | Function |
&K0 | Flow control disabled |
í &K3 | RTS/CTS flow control enabled |
&K4 | XON/XOFF flow control enabled |
JACK TYPE | |
Type: | Configuration |
Format: | AT [cmds] &Jn [cmds] |
Description: | Command non-functional; for compatability purposes only |
ON-LINE | |
Type: | Immediate |
Format: | AT [cmds] On [cmds] |
Description: | Controls on-line command (data transmission) state options. |
Note: The O command must be placed at the end of the command string. | |
Command | Function |
O0 | On-line command mode with no retraining enabled |
O1 | On-line command mode with retraining enabled |
O3-O14 | Force modem to new rate defined by register S62 |
SPEAKER VOLUME | |
Type: | Configuration |
Format: | AT [cmds] Ln [cmds] |
Description: | Controls speaker volume |
Command | Function |
L0 | Lowest volume setting |
L1 | Low volume setting |
L2 | Medium volume setting |
L3 | Highest volume setting |
TEST MODES | |
Type: | Immediate |
Format: | AT [cmds] &Tn |
Description: | Selects test options |
Command | Function |
&T0 | End current test |
&T1 | Begin local analog loopback test |
&T3 | Begin local digital loopback |
Extended AT Commands
COMPRESSION | |
Type: | Configuration |
Format: | AT [cmds] %Cn [cmds] |
Description: | Selects data compression |
Command | Function |
%C0 | Data compression disabled |
í %C1 | MNP5 enabled |
CONNECT MODE | |
Type: | Configuration |
Format: | AT [cmds] \Nn [cmds] |
Description: | Controls the type of connection the modem will operate in |
Command | Function |
\N0 | Normal mode enabled |
\N1 | Direct mode enabled |
\N2 | Reliable mode enabled |
í \N3 | Auto-reliable mode enabled |
\N4 | V.42 reliable mode enabled |
FLOW CONTROL TYPE | |
Type: | Configuration |
Format: | AT [cmds] \Qn [cmds] |
Description: | Sets type of flow control used by modem |
Command | Function |
\Q0 | Flow control disabled |
\Q1 | Bi-directional XON/XOFF flow control enabled |
\Q3 | Bi-directional RTS/CTS flow control enabled |
INACTIVITY TIMER | |
Type: | Configuration |
Format: | AT [cmds] \Tn [cmds] |
Range: | 0-90 |
Unit: | 1 minute |
Description: | Sets the length of time that the modem does not receive information before it disconnects. |
S(STATUS) -REGISTERS
DCE LINE SPEED | |
Type: | Register |
Format | AT [cmds] S37=n [cmds] |
Description: | Sets the maximum allowable data exchange rate attempted during handshake process. |
Command | Function |
í S37=0 | Speed of last connection |
S37=3 | 300bps |
S37=5 | 1200bps |
S37=6 | 2400bps |
S37=7 | 4800bps |
S37=8 | 7200bps |
S37=9 | 9600bps |
S37=10 | 12.0Kbps |
S37=11 | 14.4Kbps |
S37=12 | 16.8Kbps |
S37=13 | 19.2Kbps |
S37=14 | 21.6Kbps |
S37=15 | 24.0Kbps |
S37=16 | 26.4Kbps |
S37=17 | 28.8Kbps |
S37=18 | 33.6Kbps |
DTE RATE STATUS | |
Type: | Register |
Format | AT [cmds] S62=n [cmds] |
Description: | Sets the DTE rate status |
Command | Function |
S62=0 | 300bps |
S62=1 | 600bps |
S62=2 | 1200bps |
S62=3 | 2400bps |
S62=4 | 4800bps |
S62=5 | 9600bps |
S62=6 | 7200bps |
S62=7 | 12.0Kbps |
S62=8 | 14.4Kbps |
S62=9 | 16.8Kbps |
S62=10 | 19.2Kbps |
S62=11 | 21.6Kbps |
S62=12 | 24.0Kbps |
S62=13 | 26.4Kbps |
S62=14 | 28.8Kbps |
S62=15 | 38.4Kbps |
í S62=16 | 57.6Kbps |
S62=17 | 115.2Kbps |
DTE TRANSFER SPEED | |
Type: | Register |
Format | AT [cmds] S72=n [cmds] |
Description: | Sets the DTE speed during data transfer |
Command | Function |
í S72=0 | Last auto-baud |
S72=1 | 300bps |
S72=2 | 600bps |
S72=3 | 1200bps |
S72=4 | 2400bps |
S72=5 | 4800bps |
S72=6 | 9600bps |
S72=7 | 7200bps |
S72=8 | 12.0Kbps |
S72=9 | 14.4Kbps |
S72=10 | 16.8Kbps |
S72=11 | 19.2Kbps |
S72=12 | 21.6Kbps |
S72=13 | 24.0Kbps |
S72=14 | 26.4Kbps |
S72=15 | 28.8Kbps |
S72=16 | 38.4Kbps |
S72=17 | 57.6Kbps |
S72=18 | 115.2Kbps |
INACTIVITY TIMER | |
Type: | Register |
Format | AT [cmds] S89=n [cmds] |
Range: | 0-65 |
Default: | 65 |
Unit: | .1 seconds |
Description: | Maximum duration of DTE and DCE inactivity allowed prior to initiating stand-by mode |
Note: S30=0 disables the timer and allows indefinite inactivity. | |
TRANSMISSION LEVEL (JAPAN) | |
Type | Register or Configuration |
Format | AT [cmds] S64=n [cmds] |
Range | 9-20 |
Default | 15 |
Unit | -1 dBm |
Description | Sets the signal level for transmission (Japan version) |