MOTOROLA, INC.
VANGUARD 312 PLUS (VER. 2)
Card Type | Ethernet ISDN Router |
Chip Set | Unidentified |
Maximum Onboard Memory | 4MB DRAM |
Network Transfer Rate | 10Mbps |
Wiring Type | Unshielded twisted pair |
I/O Options | Power, UTP Ethernet interface via RJ-45 connector, 9-pin serial port ISDN interface (ST or U) via RJ-45 connector, telephone line interface via RJ-11 connectors (2) |
ISDN Data Rate | 64Kbps x 2 |
ISDN Modulation Protocol | Unidentified |
Error Correction/Compression | Unidentified |
Data Bus | External |

CONNECTIONS | |||
Function | Label | Function | Label |
DC power connector | CN1 | 9-pin data port connector | CN4 |
Phone line 1 (RJ-11) | CN2 | 10 BaseT interface (RJ-45) | CN5 |
Phone line 2 (RJ-11) | CN3 | ISDN interface (RJ-45) | ISDN |
ISDN S/T TERMINATION | ||||
Setting | SW1/1 | SW1/2 | SW1/3 | SW1/4 |
Termination disabled | On | On | On | On |
100Ohm resistance enabled | Off | Off | Off | Off |
DIAGNOSTIC LED(S) | |||
LED | Color | Status | Condition |
STS | Green | On | Software running |
STS | Green | Off | Software not running; an error has occurred |
STS | Green | Blinking | Software is being loaded |
TST | Unidentified | On | Diagnostic test(s) failed |
TST | Unidentified | Off | Device is not conducting a test |
TST | Unidentified | Blinking | Device is conducting a test |
LAN | Unidentified | Blinking | Data is being transmitted/received on Ethernet interface |
LAN | Unidentified | Off | Data is not being transmitted/received on Ethernet interface |
TLD | Unidentified | On | Telco/D channel is active |
TLD | Unidentified | Off | Telco/D channel is inactive |
B1 | Unidentified | On | B-channel 1 data call connected |
B1 | Unidentified | Blinking | B-channel 1 attached device off hook or dialing |
B1 | Unidentified | Off | No activity on B-channel 1 |
B2 | Unidentified | On | B-channel 2 data call connected |
B2 | Unidentified | Blinking | B-channel 2 attached device off hook or dialing |
B2 | Unidentified | Off | No activity on B-channel 2 |