LOGICODE TECHNOLOGY, INC.
96HV
Card Type | Modem (synchronous/asynchronous) |
Chipset | Unidentified |
Maximum Data Rate | 9600bps |
Data Modulation | Unidentified (V.32 maximum) |
Error Correction/Compression | MNP5, V.42, V.42bis |
Data Bus | 8-bit ISA |
Card Size | Unidentified |

CONNECTIONS | |||
Function | Label | Function | Label |
Telephone line | CN1 | Telephone line | CN2 |
SERIAL PORT CONFIGURATION | |||||||
Address | IRQ | SW1/1 | SW1/2 | SW1/3 | SW1/4 | SW1/5 | SW1/6 |
COM1: | 4 | Off | On | Off | Off | On | On |
COM2: | 3 | On | Off | Off | Off | On | Off |
COM3: | 4 | Off | On | Off | Off | Off | On |
COM4: | 3 | On | Off | Off | Off | Off | Off |
SUPPORTED STANDARD COMMANDS |
Basic AT Commands |
+++, ‘comma’, A/ |
A, B, E, F, H, L, M, N, O, P, Q, T, V, W, X, Y, Z |
&C, &D, &F, &G, &J, &K, &L, &P, &R, &S, &T, &V, &W, &X, &Y, &Z |
Extended AT Commands |
\A, \B, \G, \K, \L, \N, \O, \T, \U, \Y, \Z |
%C, %E, %L, %Q |
S-Registers |
S0, S1, S2, S3, S4, S5, S6, S7, S8, S9, S10, S11, S12, S18, S25, S26, S30, S36, S38, S46 |
S48, S82, S86, S91, S95 |
Note: See MHI help file for complete information. |
UNIDENTIFIED COMMANDS | |
Command | Default |
S14 | 0 |
S16 | 0 |
S21 | 0 |
S22 | 118 |
S23 | 7 |
S27 | 64 |
S40 | 57 |
S41 | 1 |
Proprietary AT Command Set
See LOGICODE TECHNOLOGY, INC. 14.4HV for a full command summary.