E-TECH RESEARCH, INC.
C1414AX PCMCIA
Card Type | Modem(synchronous/asynchronous) |
Chip Set | Unidentified |
Maximum Data Rate | 14.4Kbps |
Maximum Fax Rate | 14.4Kbps |
Data Bus | PCMCIA |
Fax Class | Class I & II |
Data Modulation Protocol | Bell 103A/212A ITU-T V.21, V.22, V.22bis, V.23, V.32, V.32bis |
Fax Modulation Protocol | ITU-T V.17, V.21CH2, V.27ter, V.29 |
Error Correction/Compression | MNP5, V.42, V.42bis |
Proprietary AT Command Set
V1795
BITS PER CHARACTER | ||
Type: | Configuration | |
Format: | AT [cmds] $Ln [cmds] | |
Description: | Controls bits per character | |
Command | Function | |
$L0 | 8 bits per character | |
$L1 | 9 bits per character | |
í $L2 | 10 bits per character | |
$L3 | 11 bits per character | |
CARRIER DETECT | ||
Type: | Configuration | |
Format: | AT [cmds] &Cn [cmds] | |
Description: | Controls DCD, Computer Systems Interface and Port Contender | |
Command | Function | |
&C0 | DCD forced high | |
í &C1 | DCD follows remote modem | |
&C2 | Conforms to Computer Systems Interface | |
&C3 | Conforms to Port Contender | |
CLEAR DOWN/DISCONNECT | ||
Type: | Configuration | |
Format: | AT [cmds] Yn [cmds] | |
Description: | Controls long space disconnect and V.32 clear down | |
Command | Function | |
í Y0 | Long space disconnect disabled | |
Y1 | Long space disconnect enabled | |
Y2 | V.32 clear down enabled | |
Y3 | V.32 clear down and long space disconnect enabled | |
COMPRESSION | ||
Type: | Configuration | |
Format: | AT [cmds] $Cn [cmds] | |
Description: | Controls data compression | |
Command | Function | |
$C0 | Data compression disabled | |
í $C1 | Data compression enabled | |
CONNECT/SPEED MESSAGE | ||
Type: | Configuration | |
Format: | AT [cmds] $Xn [cmds] | |
Description: | Controls connect and speed message displayed | |
Command | Function | |
$X0 | Normal connect and DCE speed message enabled | |
$X1 | Normal connect and DTE speed message enabled | |
í $X2 | Extended connect and DCE speed message enabled | |
$X3 | Extended connect and DTE speed message enabled | |
DIAL INTERRUPT | ||
Type: | Configuration | |
Format: | AT [cmds] $Kn [cmds] | |
Description: | Controls dial interrupt | |
Command | Function | |
$K0 | Dial interrupt disabled | |
í $K1 | Dial interrupt enabled | |
DISPLAY STORED INFORMATION | ||
Type: | Configuration | |
Format: | AT [cmds] &Vn [cmds] | |
Description: | Displays stored phone numbers, configuration profiles and S registers | |
Command | Function | |
&V0 | Display stored phone numbers | |
&V1 | Display current configuration profiles | |
&V2 | Display contents of S registers | |
&V3 | Display stored profiles briefly | |
DSR SIGNAL | ||
Type: | Configuration | |
Format: | AT [cmds] &Sn [cmds] | |
Description: | Controls DSR, Computer Systems Interface and Port Contender | |
Command | Function | |
í &S0 | DSR forced high | |
&S1 | DSR follows remote modem | |
&S2 | Conforms to Computer Systems Interface | |
&S3 | Conforms to Port Contender | |
FLOW CONTROL | ||
Type: | Configuration | |
Format: | AT [cmds] $Fn [cmds] | |
Description: | Controls XON/XOFF, ENQ/ACK, DTR/DSR AND CTS/RTS flow control | |
Command | Function | |
$F0 | XON/XOFF enabled | |
$F1 | XON/XOFF passthrough enabled | |
$F2 | ENQ/ACK enabled | |
$F3 | DTR/DSR enabled | |
í $F4 | CTS/RTS enabled | |
$F5 | Flow control disabled | |
LINE SPEED | ||
Type: | Configuration | |
Format: | AT [cmds] &Ln [cmds] | |
Description: | Controls speed at which modem attempts to connect | |
Command | Function | |
í &L0 | Line speed follows DTE speed | |
&L1 | Connect at V.23 75/1200bps | |
&L2 | Not used | |
&L3 | Connect at 300bps | |
&L4 | Not used | |
&L5 | Connect at 1200bps | |
&L6 | Connect at 2400bps | |
&L7 | Connect at 4800bps | |
&L8 | Connect at 7200bps | |
&L9 | Connect at 9600bps | |
PROTOCOL | ||
Type: | Configuration | |
Format: | AT [cmds] $En [cmds] | |
Description: | Controls protocol used | |
Command | Function | |
$E0 | Normal mode | |
$E1 | Auto MNP mode | |
$E2 | MNP mode | |
í $E3 | Auto V.42 mode | |
$E4 | LAPM mode | |
RETRAIN LIMIT | ||
Type: | Configuration | |
Format: | AT [cmds] &En [cmds] | |
Description: | Controls number of retrains per minute allowed | |
Command | Function | |
í &E0 | Disconnect If more than four retrain attempts in three minutes | |
&E1 | Disconnect If more than four retrain attempts in four minutes | |
&E2 | Disconnect If more than four retrain attempts in five minutes | |
&E3 | Unlimited retrain allowed | |
&E4 | Retrain disabled | |
SPEED CONVERSION | ||
Type: | Configuration | |
Format: | AT [cmds] $Sn [cmds] | |
Description: | Controls speed conversion | |
Command | Function | |
í $S0 | Speed conversion enabled | |
$S8 | Speed conversion disabled | |
TRANSMISSION LEVEL | ||
Type: | Configuration | |
Format: | AT [cmds] $Tn [cmds] | |
Description: | Controls transmission level | |
Command | Function | |
$T0 - $T2 | -4dBm | |
í -$T3 | -6dBm | |
$T4 | -8dBm | |
$T5 | -10dBm | |
$T6 | -12dBm | |
$T7 | -14dBm | |
$T8 | -16dBm | |