DIGITAL LINK CORPORATION
DL3200E
Card Type | E3 DSU/CSU |
Chip Set | Unidentified |
I/O Options | AC power connector, DC power and alarm relay terminal block, 9-pin serial ports (2), DTE port via 25-pin V.35 connector, DTE port via HSSI connector, monitor jack - receive, monitor jack -send, E3 network interface via BNC connectors (2), External clock via BNC connector |
E3 Transfer Rate | 2.048Mbps |
E3 Protocol | PLCP |
E3 Line Coding | RZ, HDB3 |
Frame type | G.751, G.703, G.823 |
Data Bus | External |
CONNECTIONS | |||
Function | Label | Function | Label |
BNC external clock connector | CLK | DC power & alarm relay terminal block | CN6 |
DTE port via HSSI connector | CN1 | Monitor jack - send | CN7 |
DTE port via 25-pin connector | CN2 | Monitor jack - receive | CN8 |
9-pin serial port 1 | CN3 | Fuse | F1 |
9-pin serial port 2 | CN4 | BNC E3 network interface - receive | RCV |
AC power connector | CN5 | BNC E3 network interface - transmit | XMT |
DIAGNOSTIC LEDS (DTE STATUS) | |||
LED | Color | Status | Condition |
INS | Green | On | Module is in-service and functioning normally |
INS | Yellow | On | Module is functioning normally but is not generating any alarms |
INS | Red | On | A controller failure has been detected |
NTST | Unidentified | On | Bidirectional DTE/Network loopback test is in progress |
NTST | Unidentified | Off | Module is not conducting a bidirectional DTE/Network loopback test |
TD | Unidentified | Blinking | Data is being transmitted to the E3 network |
TD | Unidentified | Off | Data is not being transmitted to the E3 network |
RD | Unidentified | Blinking | Data is being received from the E3 network |
RD | Unidentified | Off | Data is not being received from the E3 network |
RTS | Unidentified | On | RTS signal is high |
RTS | Unidentified | Off | RTS signal is low |
CTS | Unidentified | On | CTS signal is high |
CTS | Unidentified | Off | CTS signal is low |
DTR | Unidentified | On | DTR signal is high |
DTR | Unidentified | Off | DTR signal is low |
DIAGNOSTIC LEDS (PCLP ALARM STATUS) | |||
RED | Unidentified | On | Out of frame (OOF) conditions detected on received PLCP signal |
RED | Unidentified | Off | Out of frame (OOF) conditions not detected on received PLCP signal |
YEL | Unidentified | On | Receiving unit in the SMDS fabric is out of frame |
YEL | Unidentified | Off | Receiving unit in the SMDS fabric is not out of frame |
PAR | Unidentified | On | BIP8 parity errors have been detected in the receive PCLP |
PAR | Unidentified | Off | BIP8 parity errors have not been detected in the receive PCLP |
DIAGNOSTIC LEDS (E3 NETWORK STATUS) | |||
EINS | Green | On | Module is in-service and functioning normally |
EINS | Yellow | On | Module is functioning normally but is not generating any alarms |
EINS | Red | On | A module failure has been detected |
ALM | Unidentified | On | DSU/CSU is in alarm state |
ALM | Unidentified | Off | DSU/CSU is not in alarm state |
OOF | Unidentified | On | Loss of signal (LOS) or out of frame (OOF) alarm condition has been detected on E3 receive signal |
OOF | Unidentified | Off | Loss of signal (LOS) or out of frame (OOF) alarm condition has not been detected on E3 receive signal |
YEL2 | Unidentified | On | Out of frame alarm signal detected on far-end equipment |
YEL2 | Unidentified | Off | Out of frame alarm signal not detected on far-end equipment |
AIS | Unidentified | On | Alarm indication signal detected on network |
AIS | Unidentified | Off | Alarm indication signal not detected on network |
BPV | Unidentified | Blinking | Bipolar violations or HDB3 errors have been detected on E3 network |
BPV | Unidentified | Off | Bipolar violations or HDB3 errors have not been detected on E3 network |
PAR2 | Unidentified | On | BIP8 parity errors have been detected on E3 network |
PAR2 | Unidentified | Off | BIP8 parity errors have not been detected on E3 network |
DIAGNOSTIC LEDS (PROCESSOR STATUS) | |||
RXL3 | Unidentified | On | Unit is reassembling an L3_PDU |
RXL3 | Unidentified | Off | Unit is not reassembling an L3_PDU |
RXL2 | Unidentified | On | Unit is performing L2 processing on received signal |
RXL2 | Unidentified | Off | Unit is not performing L2 processing on received signal |
TXL3 | Unidentified | On | Unit is processing an L3 transmit signal |
TXL3 | Unidentified | Off | Unit is not processing an L3 transmit signal |
TXL2 | Unidentified | On | Unit is processing an L2 transmit signal |
TXL2 | Unidentified | Off | Unit is not processing an L2 transmit signal |
Note: Pressing STAT and ENTER buttons simultaniously lights all LEDs to verify lamp functionality |