Cardinal technologies, inc
mvp144i
Card Type | Modem(asynchronous), Fax |
Chip Set | Rockwell |
Maximum Data Rate | 14.4Kbps |
Maximum Fax Rate | 14.4Kbps |
Data Bus | 8-Bit ISA |
Fax Class | Class I |
Data Modulation Protocol | Bell 103A/212A ITU-T V.21, V.22, V.22bis, V.23, V.32, V.32bis |
Fax Modulation Protocol | ITU-T V.17, V.21CH2, V.27, V.29 |
Error Correction/Compression | MNP2-5, V.42, V.42bis, T.30 |
CONNECTIONS | ||||||
Function | Label | Function | Label | |||
Line in | CN1 | Line out | CN2 |
SERIAL PORT ADDRESS | |
Setting | JP1 |
COM1 (3F8h) | Pins 1 & 8, 2 & 9 closed |
COM2 (2F8h) | Pins 2 & 9 closed |
COM3 (3E8h) | Pins 1 & 8 closed |
COM4 (2E8h) | Pins 1 & 2 closed |
INTERRUPT SELECTION | |
Setting | JP1 |
2 | Pins 4 & 5, 6 & 13 closed |
3 | Pins 4 & 11, 5 & 6 closed |
4 (COM 1) | Pins 3 & 10 closed |
4 (COM 2) | Pins 3 & 10, 5 & 6 closed |
5 | Pins 5 & 12, 6 & 7 closed |
7 | Pins 5 & 6, 7 & 14 closed |
9 | Pins 4 & 5, 6 & 13 closed |
Proprietary AT Command Set
BACKSPACE CHARACTER | |
Type: | Register |
Format | AT [cmds] S5=n [cmds] |
Default: | 8 |
Range: | 0-255 |
Unit: | ASCII |
Description: | Selects a character used for backspace <BS> |
BIT MAPPED REGISTERS | |
Register | Default |
S14 | 138 |
S21 | 4 |
S22 | 117 |
S23 | 55 |
S27 | 74 |
S28 | 0 |
S31 | 194 |
S39 | 3 |
S40 | 105 |
S41 | 195 |
DCE LINE SPEED | |
Type: | Register |
Format | AT [cmds] S37=n [cmds] |
Description: | Sets the maximum allowable data exchange rate attempted during handshake process. |
Command | Function |
í S37=0 | AT command rate |
S37=3 | 300bps |
S37=5 | 1200bps in V.22 |
S37=6 | 2400bps in V.22bis |
S37=7 | 1200/75 in V.23 |
S37=8 | 4800bps in V.32bis/V.32 |
S37=9 | 9600bps in V.32bis/V.32 |
S37=10 | 12.0Kbps in V.32bis |
S37=11 | 14.4Kbps in V.32bis |
S37=12 | 7200bps in V.32bis |
DIAL | |
Type: | Immediate |
Format: | AT [cmds] D<#> [cmds] |
Description: | Dials telephone number according to any modifiers included in the string |
Note: | Any combination of modifiers can be used to produce the desired dial functions in sequence. |
Command | Function |
DL | Re-dial last number |
DP | Pulse dialing enabled |
DR | Answer mode enabled; originate mode disabled following handshake initiation. |
DS=n | Dial stored telephone number n (n=0 to 3) |
D* | Dials star digit |
D# | Dials gate digit |
DT | Tone dialing enabled/Pulse dialing disabled |
DW | Dialing resumed following dial tone detection |
D, | Dialing paused for amount of time specified in S8 register |
D& | Waits for bong tone (At&t) |
D! | Flash function initiated. Modem commanded to go off-hook for specified time before returning on-hook. |
D@ | Wait for Quiet Answer function enabled. Modem waits until a "quiet answer," a ring-back signal followed by silence of 5 seconds, is received prior to executing the rest of the dial string. |
D^ | Toggles the calling tone for current dialing attempt only |
D; | Modem returned to idle state after dialing. The semicolon can only be placed at the end of the dial command. |
DTR CHANGE THRESHOLD | |
Type: | Register |
Format | AT [cmds] S25=n [cmds] |
Default: | 5 |
Range: | 0-255 |
Unit: | .01 second |
Description: | Sets maximum time a change in the DTR signal will be ignored |
Note: | This is the function of this register when &M1 is not set. |
ESCAPE SEQUENCE GUARD TIME | |
Type: | Register |
Format | AT [cmds] S12=n [cmds] |
Default: | 50 |
Range: | 0-255 |
Unit: | .02 seconds |
Description: | Maximum allowable time between escape character sequence initiation and completion for the escape sequence to be executed. A value of 0 disables guard time. |
FACTORY DEFAULT PROFILE | |
Type: | Configuration |
Format: | AT [cmds] &Fn [cmds] |
Description: | Sets values in active profile to values found in the default profile |
Command | |
&F0 | Restores factory setting 0 |
&F1 | Restores factory setting 1 |
FLOW CONTROL | |
Type: | Configuration |
Format: | AT [cmds] &Kn [cmds] |
Description: | Enables flow control options |
Command | Function |
&K0 | Flow control disabled |
&K3 | RTS/CTS flow control enabled |
&K4 | XON/XOFF flow control enabled |
&K5 | Transparent XON/XOFF flow control enabled |
&K6 | RTS/CTS and XON/XOFF flow control enabled |
Line modulation | |
Type: | Configuration |
Format: | AT [cmds] Fn [cmds] |
Description: | Selects type of modulation used by the modem |
Command | Function |
í F0 | Auto-detect mode enabled |
F1 | V.21 or Bell 103 |
F3 | V.32 |
F4 | V.22 at 1200bps or Bell 212A |
F5 | V.22bis |
F6 | V.32bis at 4800bps or V.32 at 4800bps |
F7 | V.32bis at 7200bps |
F8 | V.32bis at 9600bps or V.32 at 9600bps |
F9 | V.32bis at 12.0Kbps |
F10 | V.32bis at 14.4Kbps |
NO CARRIER TIME-OUT | |
Type: | Register |
Format | AT [cmds] S7=n [cmds] |
Default: | 50 |
Range: | 1-255 |
Unit: | 1 second |
Description: | Maximum wait time the modem uses after dialing to detect a carrier signal from the remote modem for both originating and answering calls. |
Note: W dial modifier also uses S7 to set the maximum time to wait. |
REPORT INFORMATION | |
Type: | Immediate |
Format: | AT [cmds] In [cmds] |
Description: | Displays information requested |
Command | Function |
I0 | Reports modem product code |
I1 | Reports firmware checksum |
I2 | Tests and reports firmware checksum |
I3 | Reports firmware revision |
I4 | Reports Identifier string |
I5 | Reports country code |
I6 | Reports Data Pump modem and revision |
SLEEP TIMER | |
Type: | Register |
Format | AT [cmds] S24=n [cmds] |
Default: | 0 |
Range: | 0-255 |
Unit: | 1 second |
Description: | Maximum duration of DTE and DCE inactivity allowed prior to initiating low-power sleep mode. |