CTC UNION TECHNOLOGIES CO., LTD
G.703 FE1 FRACTIONAL E1
G.703 FRACTIONAL T1
Card Type | Fractional Access Unit |
NIC Type | E1/T1 |
Chip Set | Unidentified |
I/O Options | 25-pin DTE/DCE port, BNC connectors (2), RJ-45 connector |
Wiring Type | RJ-45 120ohm shielded twisted pair BNC 75ohm coaxial |
Maximum Data Rate | 2048Kbps |
Data Bus | External |
CONNECTIONS | |||
Function | Label | Function | Label |
RJ-45 connector | CN1 | BNC connector - transmit | TX |
25-pin serial connector | CN2 | Power switch | SW8 |
BNC connector - receive | RX |
USER CONFIGURABLE SETTINGS | |||
Setting | Label | Position | |
» | Unframe mode enabled | SW2/1 | Off |
Frame mode enabled | SW2/1 | On | |
» | Normal clock polarity - receive | SW6/3 | Off |
Inverted clock polarity - receive | SW6/3 | On | |
» | Normal clock polarity - transmit | SW6/4 | Off |
Inverted clock polarity - transmit | SW6/4 | On | |
» | CRC4 disabled | SW6/5 | Off |
CRC4 enabled | SW6/5 | On | |
» | CAS/PCM30 mode | SW6/6 | Off |
CAS/PCM31 mode | SW6/6 | On | |
» | Unused timeslot - Mark | SW6/7 | Off |
Unused timeslot - Pass-through | SW6/7 | On | |
» | DCE data port enabled | SW6/8 | Off |
DTE data port enabled | SW6/8 | On | |
Note: When cascading, SW6/7 must be set to on. |
LINE IMPEDANCE | ||||||
Setting | SW1/1 | SW1/2 | SW1/3 | SW1/4 | SW1/5 | |
» | 75ohm unbalanced network interface | Off | Off | On | On | On |
120ohm balanced network interface | On | On | Off | Off | Off |
TIMESLOT SELECTION | |||||||
Setting | SW2/2 | SW2/3 | SW2/4 | SW2/5 | SW2/6 | SW2/7 | SW2/8 |
Timeslot 1 active | On | Off | Off | Off | Off | Off | Off |
Timeslot 2 active | Off | On | Off | Off | Off | Off | Off |
Timeslot 3 active | Off | Off | On | Off | Off | Off | Off |
Timeslot 4 active | Off | Off | Off | On | Off | Off | Off |
Timeslot 5 active | Off | Off | Off | Off | On | Off | Off |
Timeslot 6 active | Off | Off | Off | Off | Off | On | Off |
Timeslot 7 active | Off | Off | Off | Off | Off | Off | On |
Note: Off position sets timeslots to idle. Cascaded units must not be assigned identical or overlapping timeslots |
TIMESLOT SELECTION (CONT.) | ||||||||
Setting | SW3/1 | SW3/2 | SW3/3 | SW3/4 | SW3/5 | SW3/6 | SW3/7 | SW3/8 |
Timeslot 8 active | On | Off | Off | Off | Off | Off | Off | Off |
Timeslot 9 active | Off | On | Off | Off | Off | Off | Off | Off |
Timeslot 10 active | Off | Off | On | Off | Off | Off | Off | Off |
Timeslot 11 active | Off | Off | Off | On | Off | Off | Off | Off |
Timeslot 12 active | Off | Off | Off | Off | On | Off | Off | Off |
Timeslot 13 active | Off | Off | Off | Off | Off | On | Off | Off |
Timeslot 14 active | Off | Off | Off | Off | Off | Off | On | Off |
Timeslot 15 active | Off | Off | Off | Off | Off | Off | Off | On |
Note: Off position sets timeslots to idle. Cascaded units must not be assigned identical or overlapping timeslots |
TIMESLOT SELECTION (CONT.) | ||||||||
Setting | SW4/1 | SW4/2 | SW4/3 | SW4/4 | SW4/5 | SW4/6 | SW4/7 | SW4/8 |
Timeslot 16 active | On | Off | Off | Off | Off | Off | Off | Off |
Timeslot 17 active | Off | On | Off | Off | Off | Off | Off | Off |
Timeslot 18 active | Off | Off | On | Off | Off | Off | Off | Off |
Timeslot 19 active | Off | Off | Off | On | Off | Off | Off | Off |
Timeslot 20 active | Off | Off | Off | Off | On | Off | Off | Off |
Timeslot 21 active | Off | Off | Off | Off | Off | On | Off | Off |
Timeslot 22 active | Off | Off | Off | Off | Off | Off | On | Off |
Timeslot 23 active | Off | Off | Off | Off | Off | Off | Off | On |
Note: Off position sets timeslots to idle. Cascaded units must not be assigned identical or overlapping timeslots |
TIMESLOT SELECTION (CONT.) | ||||||||
Setting | SW5/1 | SW5/2 | SW5/3 | SW5/4 | SW5/5 | SW5/6 | SW5/7 | SW5/8 |
Timeslot 24 active | On | Off | Off | Off | Off | Off | Off | Off |
Timeslot 25 active | Off | On | Off | Off | Off | Off | Off | Off |
Timeslot 26 active | Off | Off | On | Off | Off | Off | Off | Off |
Timeslot 27 active | Off | Off | Off | On | Off | Off | Off | Off |
Timeslot 28 active | Off | Off | Off | Off | On | Off | Off | Off |
Timeslot 29 active | Off | Off | Off | Off | Off | On | Off | Off |
Timeslot 30 active | Off | Off | Off | Off | Off | Off | On | Off |
Timeslot 31 active | Off | Off | Off | Off | Off | Off | Off | On |
Note: Off position sets timeslots to idle. Cascaded units must not be assigned identical or overlapping timeslots |
TIMING SOURCE | |||
Setting | SW6/1 | SW6/2 | |
» | Receive - recovery/transmit - data port | Off | Off |
Receive/transmit - data port | Off | On | |
Receive/transmit - recovery | On | Off | |
Receive/transmit - internal oscillator | On | On | |
Note: Default setting cannot be used if SW6/7 is set to on. |
TEST MODE | ||
Setting | Label | Position |
C703 loopback test enabled | SW7 | 1 |
Normal mode enabled | SW7 | 2 |
Dataport loopback test enabled | SW7 | 3 |
DIAGNOSTIC LED(S) | |||
LED | Color | Status | Condition |
DTE | Green | On | DTE mode enabled; power is on |
DTE | Green | Off | DTE mode disabled; power is off |
DCE | Green | On | DCE mode enabled; power is on |
DCE | Green | Off | DCE mode disabled; power is off |
TD | Yellow | On | Ones are being transmitted to network |
TD | Yellow | Off | Zeros are being transmitted to network |
TD | Yellow | Blinking | Ones and zeros are being transmitted to network |
RD | Yellow | On | Ones are being received from network |
RD | Yellow | Off | Zeros are being received from network |
RD | Yellow | Blinking | Ones and zeros are being received from network |
TST | Red | On | Access unit is executing a test |
TST | Red | Off | Access unit is not executing a test |
ALM | Red | On | Alarm condition detected on network |
ALM | Red | Off | Alarm condition not detected on network |
TXL | Red | On | Transmit clock loss detected |
TXL | Red | Off | Transmit clock loss not detected |
RXL | Red | On | Receive signal loss detected |
RXL | Red | Off | Receive signal loss not detected |