CREATIX POLYMEDIA
AT&T 28.8 (EXTERNAL)
Card Type | Modem (synchronous/asynchronous) |
Chip Set | AT&T |
I/O Options | Voice |
Maximum Data Rate | 28.8Kbps |
Maximum Fax Rate | 14.4Kbps |
Data Bus | External |
Fax Class | Class I & II |
Data Modulation Protocol | Bell 103A/212A ITU-T V.21, V.22, V.22bis, V.23, V.32, V.32bis, V.32terbo, V.34 |
Fax Modulation Protocol | ITU-T V.17, V.21CH2, V.27ter, V.29 |
Error Correction/Compression | MNP5, V.42, V.42bis |
CONNECTIONS | ||||||
Function | Label | Function | Label | |||
Line in | CN1 | DC power | CN4 | |||
Line out | CN2 | Power switch | SW1 | |||
RS-232/422 | CN3 |
DIAGNOSTIC LED(S) | |||
LED | Color | Status | Condition |
MR | Red | On | Power is on |
MR | Red | Off | Power is off |
TR | Red | On | DTR signal is high |
TR | Red | Off | DTR signal is low |
SD | Red | On | Modem is transmitting data |
SD | Red | Off | Modem is not transmitting data |
RD | Red | On | Modem is receiving data |
RD | Red | Off | Modem is not receiving data |
OH | Red | On | Modem is off-hook |
OH | Red | Off | Modem is on-hook |
CD | Red | On | Carrier signal detected |
CD | Red | Off | Carrier signal not detected |
AA | Red | On | Auto-answer enabled |
AA | Red | Off | Auto-answer disabled |
EC | Red | On | Error correction enabled |
EC | Red | Off | Error correction disabled |
Proprietary AT Command Set
AUTO-RELIABLE FALLBACK CHARACTER | |
Type: | Configuration |
Format: | AT [cmds] %An [cmds] |
Default: | 0 |
Range: | 0-127 |
Unit: | ASCII |
Description: | Sets the character used as the auto-reliable fallback character. %A0 will disable this function. |
AUTO-RELIABLE FALLBACK CHARACTER | |
Type: | Register |
Format: | AT [cmds] S29=n [cmds] |
Default: | 0 |
Range: | 0-127 |
Unit: | ASCII |
Description: | Sets the character used as the auto-reliable fallback character. %A0 will disable this function. |
AUTO-RELIABLE TIME BUFFER CONFIGURATION | |
Type: | Configuration |
Format: | AT [cmds] \Cn [cmds] |
Description: | Controls the handling of incoming data during auto-reliable time period |
Command | Function |
í \CO | Data is discarded |
\C1 | Data is buffered |
\C2 | Data is discarded, sets to normal mode and sends auto-reliable character to serial port. |
AUTO-RETRAIN - FALLBACK/FALLFORWARD | |
Type: | Configuration |
Format: | AT [cmds] %En [cmds] |
Description: | Controls auto-retrain mode and fallback/fall forward |
Command | Function |
%E0 | Auto-retrain disabled |
%E1 | Auto-retrain enabled |
í %E2 | Fallback/fall forward enabled |
BIT MAPPED REGISTERS | |
Register | Default |
S14 | 137 |
S15 | 83 |
S16 | 0 |
S17 | 75 |
S19 | 3 |
S20 | 0 |
S21 | 48 |
S22 | 246 |
S23 | 12 |
S24 | 72 |
S27 | 0 |
S28 | 16 |
BREAK SEND | |
Type: | Configuration |
Format: | AT [cmds] \Bn [cmds] |
Default: | 3 |
Range: | 0-9 |
Unit: | .1 second |
Description: | Sends break to modem |
BREAK TYPE | |
Type | Configuration |
Format | AT [cmds] \Kn [cmds] |
Default | 5 |
Range | 0-5 |
Description | Configures action of break signal |
COMPRESSION | |
Type: | Configuration |
Format: | AT [cmds] %Cn [cmds] |
Description: | Controls data compression |
Command | Function |
%C0 | Data compression disabled |
í %C1 | Data compression enabled |
CONNECT MODE | |
Type: | Configuration |
Format: | AT [cmds] \Nn [cmds] |
Description: | Sets connect mode |
Command | Function |
\N0 | Normal mode enabled |
\N1 | Direct mode enabled |
\N2 | MNP mode only enabled |
í \N3 | LAP-M/MNP/Normal mode enabled |
\N4 | LAP-M mode only enabled |
\N5 | LAP-M/Normal mode enabled |
\N6 | LAP-M/MNP mode enabled. |
\N7 | MNP/Normal mode enabled |
CONNECTION SPEED UPPER LIMIT | |
Type: | Immediate |
Format: | AT [cmds] %Bn [cmds] |
Description: | Selects the maximum DCE connection speed |
Command | Function |
%B300 | Select 300bps speed |
%B1200 | Select 1200bps speed |
%B2400 | Select 2400bps speed |
%B4800 | Select 4800bps speed |
%B7200 | Select 7200bps speed |
%B9600 | Select 9600bps speed |
%B12000 | Select 12Kbps speed |
%B14400 | Select 14.4Kbps speed |
%B16800 | Select 16.8Kbps speed |
%B19200 | Select 19.2Kbps speed |
%B21600 | Select 21.6Kbps speed |
%B24000 | Select 24Kbps speed |
%B26400 | Select 26.4Kbps speed |
%B28800 | Select 28.8Kbps speed |
DTE BAUD RATE | ||
Type: | Configuration | |
Format: | AT [cmds] %Nn [cmds] | |
Description: | Controls DTE baud rate | |
Command | Function | |
í %N0 | IBM PC | |
%N1 | NEC PC98 set 1 | |
%N2 | NEC PC98 set 2 | |
Note: For use with external models |
EXTENDED RESULT CODES | |
Type: | Configuration |
Format: | AT [cmds] \Vn [cmds] |
Description: | Selects extended result codes |
Command | Function |
\V0 | Modem speed result codes enabled |
\V1 | Modem speed and basic REL result codes enabled |
í \V2 | All extended result codes enabled |
\V3 | Computer speed result codes enabled |
FLOW CONTROL | |
Type: | Configuration |
Format: | AT [cmds] \Gn [cmds] |
Description: | Selects modem port flow control |
Command | Function |
í \G0 | Flow control disabled |
\G1 | Flow control enabled |
FLOW CONTROL TYPE | |
Type: | Configuration |
Format: | AT [cmds] \Qn [cmds] |
Description: | Sets type of flow control used by modem |
Command | Function |
\Q0 | Flow control disabled |
\Q1 | Bidirectional XON/XOFF flow control enabled |
\Q2 | CTS flow control by DCE enabled |
í \Q3 | CTS/RTS flow control enabled |
\Q4 | Unidirectional XON/XOFF flow control enabled |
INACTIVITY TIMER | |
Type: | Configuration |
Format: | AT [cmds] \Tn [cmds] |
Default: | 0 |
Range: | 0-90 |
Unit: | 1 minute |
Description: | Sets the length of time that the modem does not receive information before it disconnects |
LINE SIGNAL QUALITY | |
Type: | Immediate |
Format: | AT [cmds] %Q [cmds] |
Description: | Displays line signal quality and receive level in dBm |
DUMB MODE | |
Type: | Configuration |
Format: | AT [cmds] %Dn [cmds] |
Description: | Controls smart/dumb mode |
Command | Function |
í %D0 | Smart mode enabled |
%D1 | Dumb mode enabled |
LOCK SERIAL PORT | |
Type: | Configuration |
Format: | AT [cmds] \Jn [cmds] |
Description: | Sets operation of serial port speed |
Command | Function |
í \J0 | Serial speed locked |
\J1 | Serial speed follows connect speed |
MAXIMUM BLOCK SIZE FOR TRANSMISSION | |
Type: | Configuration |
Format: | AT [cmds] \An [cmds] |
Description: | Sets the maximum transmittable block size |
Command | Function |
\A0 | MNP block size is 64 characters |
\A1 | MNP block size is 128 characters |
\A2 | MNP block size is 192 characters |
í \A3 | MNP block size is 256 characters |
MODULATION SELECTION | ||
Type: | Configuration | |
Format: | AT [cmds] \Mn [cmds] | |
Description: | Controls V.34 and V.32terbo modulation selection | |
Command | Function | |
í \M0 | V.34 and V.32terbo enabled | |
\M1 | V.32terbo disabled | |
\M2 | V.34 disabled |
SLEEP TIMER | |
Format | AT [cmds] S13=n [cmds] |
Default: | 6 |
Range: | 0-255 |
Unit: | 1 second |
Description: | Maximum duration of DTE and DCE inactivity allowed prior to initiating low-power sleep mode |
TRANSMIT ATTENUATION | |
Type: | Register |
Format: | AT [cmds] S91=n [cmds] |
Default: | 12 |
Range: | 0-15 |
Unit: | -1dBm |
Description: | Controls attenuation for transmit level |
XON/XOFF PASS-THROUGH | |
Type: | Configuration |
Format: | AT [cmds] \Xn [cmds] |
Description: | Selects whether XON/XOFF signals are sent to remote modem |
Command | Function |
í \X0 | XON/XOFF signals trapped by local modem |
\X1 | XON/XOFF passed through local modem |