BOCA RESEARCH, INC.
BOCA OFFICE COMMUNICATOR V.34 (FDVSP34I)
Card Type | Modem/speakerphone |
Chip Set | Unidentified |
Maximum Data Rate | 28.8Kbps |
Maximum Fax Rate | 14.4Kbps |
Data Bus | 8 bit ISA |
Fax Class | Class I & II |
Data Modulation Protocol | Bell 103A/212A ITU-T V.21, V.22, V.22bis, V.32, V.32bis, V.34 Rockwell V.FC |
Fax Modulation Protocol | ITU-T V.17, V.21CH2, V.27ter, V.29 |
Error Correction/Compression | MNP5, V.42, V.42bis |

CONNECTIONS | ||||||
Function | Label | Function | Label | |||
Line in | CN1 | Microphone | CN3 | |||
Line out | CN2 | Speaker | CN4 | |||
Proprietary AT Command Set
AUTO RETRAIN FALLBACK/FALLFORWARD | ||
Type | Configuration | |
Format | AT [cmds] %En [cmds] | |
Description | Controls auto retrain mode and fallback/fallforward | |
Command | Function | |
%E0 | Auto retrain disabled | |
%E1 | Auto retrain enabled | |
í %E2 | Auto retrain and fallback/fallforward enabled | |
BREAK SEND | |
Type | Configuration |
Format | AT [cmds] \Bn [cmds] |
Default | 3 |
Range | 1-9 |
Unit | .1 second |
Description | Sends break of n length to remote modem |
BREAK TYPE | |||||
Type: | Configuration | ||||
Format: | AT [cmds] \Kn [cmds] | ||||
Description: | Configures action of break signal. | ||||
Command | Break from DTE while in reliable mode | Break from DTE while in normal mode | Break from DTE while in direct mode | ||
\K0 | Enter command mode, do not send break to remote modem | Buffers cleared and break sent to remote modem | Send break and enter command mode | ||
\K1 | Buffers cleared and break sent to remote modem | Buffers cleared and break sent to remote modem | Send break and enter command mode | ||
\K2 | Enter command mode, do not send break to remote modem | Send break to remote modem immediately | Send break to remote modem immediately | ||
\K3 | Send break to remote modem immediately | Send break to remote modem immediately | Send break and enter command mode | ||
\K4 | Enter command mode, do not send break to remote modem | Send break to remote modem with transmitted data | Send break to remote modem immediately | ||
í \K5 | Send break with transmitted data | Send break to remote modem with transmitted data | Send break to remote modem immediately | ||
COMPRESSION | |
Type | Configuration |
Format | AT [cmds] %Cn [cmds] |
Description | Selects data compression |
Command | Function |
%C0 | Data compression disabled |
%C1 | MNP5 enabled |
%C2 | V.42bis enabled |
í %C3 | MNP5 and V.42bis enabled |
FAX TRANSMIT LEVEL | |
Type | Register |
Format | AT [cmds] S92=n [cmds] |
Default | 10 |
Range | 0-15 |
Unit | -1dBm |
Description | Controls fax transmission level |
FLASH DIAL MODIFIER TIME | |
Type | Register |
Format | AT [cmds] S29=n [cmds] |
Default | 10 |
Range | 0-255 |
Unit | 1ms |
Description | Time the modem will go on-hook upon receiving the ! dial modifier in dial string |
FLOW CONTROL CHARACTER - XOFF | |
Type | Register |
Format | AT [cmds] S33=n [cmds] |
Default | 19 |
Range | 0-255 |
Unit | ASCII |
Description | Sets the character used to represent XOFF |
FLOW CONTROL CHARACTER - XON | |
Type | Register |
Format | AT [cmds] S32=n [cmds] |
Default | 17 |
Range | 0-255 |
Unit | ASCII |
Description | Sets the character used to represent XON |
LINE SIGNAL LEVEL | |
Type | Immediate |
Format | AT [cmds] %L [cmds] |
Range | 009-043 |
Unit | -1dBm |
Description | Reports received signal level |
MAXIMUM BLOCK SIZE FOR TRANSMISSION | ||
Type | Configuration | |
Format | AT [cmds] \An [cmds] | |
Description | Sets the maximum transmittable block size. | |
Command | Function | |
\A0 | Maximum MNP block size is 64 characters. | |
í \A1 | Maximum MNP block size is 128 characters. | |
\A2 | Maximum MNP block size is 192 characters. | |
\A3 | Maximum MNP block size is 256 characters. | |
MODEM PROTOCOL | ||
Type | Configuration | |
Format | AT [cmds] \Nn [cmds] | |
Description | Sets connect mode | |
Command | Function | |
\N0 | Normal mode enabled | |
\N1 | Direct mode enabled | |
\N2 | Reliable mode enabled | |
í \N3 | MNP or normal mode enabled | |
\N4 | LAP-M reliable enabled | |
\N5 | MNP reliable mode enabled | |
PROTOCOL/SPEED | ||
Type | Register | |
Format | AT [cmds] S37=n [cmds] | |
Description | Selects switched line speed | |
Command | Function | |
í S37=0 | Connect at highest common speed | |
S37=1 | Connect at 300bps | |
S37=2 | Connect at 300bps | |
S37=3 | Connect at 300bps | |
S37=4 | Not used | |
S37=5 | Connect at 1200bps | |
S37=6 | Connect at 2400bps | |
S37=7 | Connect at V.23 | |
S37=8 | Connect at 4800bps | |
S37=9 | Connect at 9600bps | |
S37=10 | Connect at 12.0Kbps | |
S37=11 | Connect at 14.4Kbps | |
S37=12 | Connect at 7200bps | |
REPORT SIGNAL QUALITY | |
Type | Immediate |
Format | AT [cmds] %Q [cmds] |
Description | Reports signal quality. Retrain threshold is 008 or greater. |
SLEEP INACTIVITY TIMER | |
Type | Register |
Format | AT [cmds] S24=n [cmds] |
Default | 0 |
Range | 0-255 |
Unit | Second |
Description | Maximum duration of DTE and DCE inactivity allowed prior to initiating low-power sleep mode |
BIT MAPPED REGISTERS | |
Register | Default |
S14 | 138 |
S16 | 0 |
S21 | 4 |
S22 | 117 |
S23 | 54 |
S27 | 9 |
S28 | 0 |
S31 | 2 |
S39 | 3 |
S40 | 105 |
S41 | 3 |