BOCA RESEARCH, INC.
BOCAMODEM M144IW
Modem Type | Data (synchronous/asynchronous)/Fax |
Maximum Data Rate | 14.4Kbps |
Maximum Fax Rate | 9600bps |
Data Bus | 8-bit ISA |
Fax Class | Class I & II |
Data Modulation Protocol | Bell 103A/212A ITU-T V.21, V.22, V.22bis, V.23, V.32, V.32bis |
Fax Modulation Protocol | ITU-T V.21CH2, V.27ter, V.29 |
Error Correction/Compression | MNP5, V.42, V.42bis |

CONNECTIONS | |||
Purpose | Location | Purpose | Location |
Line out | CN1 | Line in | CN2 |
BASE I/O ADDRESS SELECTION | ||||
Port | JP1/A | JP1/B | JP1/C | JP1/D |
| » COM1: (3F8h) | Closed | Open | Open | Open |
| COM2: (2F8h) | Open | Closed | Open | Open |
| COM3: (3E8h) | Open | Open | Closed | Open |
| COM4: (2E8h) | Open | Open | Open | Closed |
INTERRUPT SELECTION | ||||
IRQ | JP1/E | JP1/F | JP1/G | JP1/H |
| 3 | Closed | Open | Open | Open |
| » 4 | Open | Closed | Open | Open |
| 5 | Open | Open | Closed | Open |
| 7 | Open | Open | Open | Closed |
Proprietary AT Command Set
AUTO-RETRAIN - FALLBACK/FALLFORWARD | |
Type: | Configuration |
Format: | AT [cmds] %En [cmds] |
Example: | AT %E1 <CR> |
Description: | Controls auto-retrain mode and fallback/fall forward. |
| Command | Function |
| » %E0 | Auto-retrain disabled. |
| %E1 | Auto-retrain enabled. |
| %E2 | Fallback/fall forward enabled. |
BIT-MAPPED REGISTERS | |
Registers | Default |
S14 | 170 |
S21 | 0 |
S22 | 117 |
S23 | 7 |
S27 | 9 |
S28 | Unidentified |
S31 | Unidentified |
S39 | Unidentified |
S40 | Unidentified |
S41 | Unidentified |
BREAK SEND | |
Type: | Configuration |
Format: | AT [cmds] \Bn [cmds] |
Example: | AT \B3 <CR> |
Default: | 3 |
Range: | 1-9 |
Unit: | .1 second |
Description: | Sends break to modem. |
BREAK TYPE | ||||
Type: | Configuration | |||
Format: | AT [cmds] \Kn [cmds] | |||
Example: | AT \K1 <CR> | |||
Description: | Configures action of break signal. | |||
Command | Break from DTE MNP/Normal mode | Break from DTE Direct mode | Break from remote modem | |
| \K0 | Enter command mode, do not send break to remote modem. | Send break to remote modem immediately, then enter command mode. | Buffers cleared and break sent to DTE. | |
| \K1 | Buffers cleared and break sent to remote modem. | Send break to remote modem immediately, then enter command mode. | Buffers cleared and break sent to DTE. | |
| \K2 | Enter command mode, do not send break to remote modem. | Send break to remote modem immediately. | Send break to DTE immediately. | |
| \K3 | Send break to remote modem immediately. | Send break to remote modem immediately, then enter command mode. | Send break to DTE immediately. | |
| \K4 | Enter command mode, do not send break to remote modem. | Send break to remote modem immediately. | Break sent with received data to the DTE. | |
| » \K5 | Send break with transmitted data. | Send break to remote modem immediately. | Break sent with received data to the DTE. | |
COMPRESSION | |
Type: | Configuration |
Format: | AT [cmd] %Cn [cmd] |
Example: | AT \N2 %C1 \K5 <CR> |
Description: | Selects data compression. |
| Command | Function |
| %C0 | Data compression disabled. |
| %C1 | MNP5 enabled. |
| %C2 | V.42bis enabled. |
| » %C3 | MNP5 and V.42bis enabled. |
CONNECT MODE | |
Type: | Configuration |
Format: | AT [cmds] \Nn [cmds] |
Example: | AT \N1 DT555-1212 <CR> |
Description: | Sets connect mode. |
| Command | Function |
\N0 | Normal mode enabled. |
\N1 | Direct mode enabled. |
\N2 | Reliable mode enabled. |
\N3 | Auto-reliable mode enabled, MNP mode with fallback to Normal mode. |
\N4 | LAPM error-correction mode enabled. |
\N5 | MNP error-correction mode enabled. |
FAX TRANSMIT LEVEL | |
Type: | Register |
Format: | AT [cmds] S92=n [cmds] |
Example: | ATS92=10 <CR> |
Default: | 10 |
Range: | 1-15 |
Unit: | -1dBm |
Description: | Controls fax transmission level. |
FLOW CONTROL | |
Type: | Configuration |
Format: | AT [cmds] \Gn [cmds] |
Example: | AT \G1 &K3 <CR> |
Description: | Selects modem port flow control. |
Command | Function |
| » \G0 | Flow control disabled. |
| \G1 | Flow control enabled. |
FLOW CONTROL CHARACTER - XOFF | |
Type: | Register |
Format: | AT [cmds] S33=n [cmds] |
Example: | ATS33=19 <CR> |
Default: | 19 |
Range: | 0-255 |
Unit: | ASCII |
Description: | Sets the character used to represent XOFF. |
FLOW CONTROL CHARACTER - XON | |
Type: | Register |
Format: | AT [cmds] S32=n [cmds] |
Example: | ATS32=17 <CR> |
Default: | 17 |
Range: | 0-255 |
Unit: | ASCII |
Description: | Sets the character used to represent XON. |
LINE SIGNAL LEVEL | |
Type: | Configuration |
Format: | AT [cmds] %L [cmds] |
Example: | AT %L &W <CR> |
Default: | Unidentified |
Range: | 9-43 |
Unit: | -1 dBm |
Description: | Returns received line signal level. |
MAXIMUM BLOCK SIZE FOR TRANSMISSION | |
Type: | Configuration |
Format: | AT [cmds] \An [cmds] |
Example: | AT \A1 %C1 <CR> |
Description: | Sets the maximum transmittable block size. |
| Command | Function |
| \A0 | MNP block size is 64 characters. |
| » \A1 | MNP block size is 128 characters. |
| \A2 | MNP block size is 192 characters. |
| \A3 | MNP block size is 256 characters. |
MNP STREAM/BLOCK MODE | |
Type: | Configuration |
Format: | AT [cmds] \Ln [cmds] |
Example: | AT \L1 DT555-1212 <CR> |
Description: | Selects the transfer mode for MNP. |
| Command | Function |
| » \L0 | Stream mode for MNP enabled. |
| \L1 | Block mode for MNP enabled. |
MNP10 LINK NEGOTIATION | |
Type: | Configuration |
Format: | AT [cmds] *Hn [cmds] |
Example: | AT *H0 \W1 <CR> |
Description: | Sets the speed at which MNP10 link negotiation will occur. |
| Command | Function |
| » *H0 | Link will be negotiated at highest possible speed. |
| *H1 | Link will be negotiated at 1200bps. |
PSTN TRANSMIT LEVEL | |
Type: | Register |
Format: | AT [cmds] S91=n [cmds] |
Example: | ATS91=10 <CR> |
Default: | 10 |
Range: | 1-15 |
Unit: | -1dBm |
Description: | Controls PSTN transmission level. |
REPORT SIGNAL QUALITY | |
Type: | Configuration |
Format: | AT [cmds] %Q [cmds] |
Example: | AT %Q &W <CR> |
Range: | 0-255 |
Description: | Reports signal quality. |
Note: A value of 8 or greater retrain enabled, only when %E1 is enabled. | |
SLEEP TIMER | |
Format | AT [cmds] S24=n [cmds] |
Example: | ATS24=0 <CR> |
Default: | 0 |
Range: | 0 - 255 |
Unit: | 1 second |
Description: | Maximum duration of DTE and DCE inactivity allowed prior to initiating low-power sleep mode. |
TEST MODES | |||
Format | AT [cmds] S16=n [cmds] | ||
Example: | ATS16=128 <CR> | ||
Default: | 128 | ||
Range: | 0 - 255 | ||
Unit: | Bit-mapped | ||
Description: | Select type of loopback test. | ||
Bit | Value | Function | |
0 | 0 1 | Local analog loopback test not in progress. Local analog loopback test in progress. | |
1 | 0 1 | Remote analog loopback test not in progress. Remote analog loopback test in progress. | |
2 | 0 1 | Local digital loopback test not in progress. Local digital loopback test in progress. | |
3 | 0 1 | Remotely requested remote digital loopback test not in progress. Remotely requested remote digital loopback test in progress. | |
4 | 0 1 | Locally requested remote digital loopback test not in progress. Locally requested remote digital loopback test in progress. | |
5 | 0 1 | Remote digital loopback with local self-test not in progress. Remote digital loopback with local self-test in progress. | |
6 | 0 1 | Local analog loopback with local self-test not in progress. Local analog loopback with local self-test in progress. | |
7 | 0» 1 | Remote analog loopback with local self-test not in progress. Remote analog loopback with local self-test in progress. | |
V.23 DIRECTION CONTROL | |
Type: | Configuration |
Format: | AT [cmds] %Fn [cmds] |
Example: | AT %F1 &W <CR> |
Description: | Controls the direction of transmit/receive 75/1200bps, only when \W1 is selected. |
| Command | Function |
| %F0 | 75bps transmit/1200bps receive enabled. |
| » %F1 | 1200bps transmit/75bps receive enabled. |
V.23 SPLIT BAUD MODE | |
Type: | Configuration |
Format: | AT [cmds] \Wn [cmds] |
Example: | AT \W1 <CR> |
Description: | Controls V.23 split baud mode. |
| Command | Function |
| » \W0 | V.23 split baud mode disabled. |
| \W1 | V.23 split baud mode enabled. |